Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting (mm) 1in = 25.4mm Minimum strokes are as follows based on the space required for mounting auto switches.
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7V D-F7WV D-F7BAVL Approx.
Auto switch mounting surface Bore size (mm) 20, 25 63, 80, 100 32, 40, 50 Port side Port side Port side C A C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side A, B, C sides A, B, C sides Port, A, B, C sides BQ-2 BQ2-012 Two kinds of auto switch mounting brackets are used as a set.
D-C80C D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73 D-A80 D-A79W Bore B A B A B A B A B A 32 8 (6) 7 (5) 8.5 (6.5) 14.5 (11.5) 9 (7) 8 (6) 7 (5) 6 (4) 6 (5) 12 (9) 40 10 (
A B A 32 6 7 7 8 40 11 13 12 14 Aim at this number.
Hs A B A B Proper Auto Switch Mounting Position Auto Switch Mounting Height D-A7H D-A80H D-F7 D-A7H, A80H D-A73C, A80C D-F7, F7V D-F79F, J79 D-J79C, F7W D-F7WV, J79W D-F7BAL, F7BAVL D-J79W D-F7BAL D-F79F D-F7NTL D-F7V D-A7 D-A80 D-A73C D-A80C D-J79C D-A79W D-F7WV Bore size (mm) D-A7, A80 D-A79W D-F7NTL Bore size (mm) D-J79 D-F7W D-F7BAVL Hs Hs Hs Hs Hs Hs 20 A B A B A B A B 25 20 32 25 31.5
TU0212 B 20 Length per roll Tubing model Symbol 20 Roll size 20m roll Caution Color Symbol B W R BU Y G C Color Black White Red Blue Yellow Green Clear 1 Applicable for general industry water. Please consult with SMC if using for other kinds of fluids. Surge pressure must be under the max. operating pressure.
Hs A B A B 32 to 50 D-A73C D-A80C D-J79C D-A79W D-F7W D-F7V Approx. Hs Approx.
Hs A B A B Proper Auto Switch Mounting Position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W Bore size (mm) B B A A B A B A 32 3 11 51 43 6 46 5.5 45.5 40 5.5 13.5 49.5 57.5 8.5 52.5 8 52 50 19 11 53.5 61.5 14 56.5 13.5 56 63 22 14 59 67 17 62 16.5 61.5 Auto Switch Mounting Height (mm) D-A7H, A80H D-F7, J79, F7W D-J79W
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
Hs A B A B Proper auto switch mounting position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W D-F7LF Bore size (mm) B B A A B A B A B A 32 11 10 50 51 3 43 6 46 5.5 45.5 40 13.5 12.5 56.5 57.5 5.5 49.5 8.5 52.5 8 52 50 18 19 61.5 60.5 11 53.5 14 56.5 13.5 56 63 22 21 67 66 14 59 17 62 16.5 61.5 Auto switch mounting height
Inset the signal cable through the hole and fit the nipple A, nipple B and lock nut. Then fit the cap A, cap B and rubber bushing. Recommended cable diameter: 6 to 13 mm Signal cable entry For option B Signal cable entry Lock nut Nipple A Rubber bush Nipple B Cap B Cap A Fig. 3-9 Mounting to the cable gland Fit the nipple A and nipple B closely until it clicks.
Inset the signal cable through the hole and fit the nipple A, nipple B and lock nut. Then fit the cap A, cap B and rubber bushing. Recommended cable diameter: 6 to 13 mm Signal cable entry For option B Signal cable entry Lock nut Nipple A Rubber bush Nipple B Cap B Cap A Fig. 3-9 Mounting to the cable gland Fit the nipple A and nipple B closely until it clicks.
How to Order T 0604 B 20 Length per roll Color Symbol Color Nylon tubing 20 100 Max. operating pressure is 1.3 max of burst pressure at 60C, considering the safety ratio. 20m 100m roll B W R BU Y G Black White Tubing size Red Blue O.D. 6, I.D. 4 Yellow Green 1.17-15 D.P. Lube Series ALD600/900 Standard Specifications AC Centralized control of multi-point lubrication (1) Model name D.P.
cable O.D.: 6.8 to 11.5) CE1 CE2 Proper Auto Switch Mounting Position D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C ML2B D-G39 D-K39 D-A33/A34 D-A44 D-B5 D-B64 D-B59W D-G5NTL Bore size (mm) C J G5-S A B A B A B A B A B A B CV 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 25 MVGQ 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5
(800) 258-9200-www.stevenengineering.com CRA1 With double shaft DD W D CRQ2 I K Auto switch MSQ b (10) Max. 2Rc 1/8 (Port size) H F MRQ (US) (UW) DCB Q BC 20M N BB BA BA G D A (AU)Max S L TG effective depth TL TF effective depth TL TD TB TC (mm) D (g6) DD (h9) Rotating angle A AU B BA BB Size BE J JA JB BC BD BU CA CB F H 90, 180 90, 180 40 90, 180 20 30 10 12 15 8.3 32 30 32 36 M8 x 1.25
Refer to Fig.1) 3) Remove the junction box B (top) for all stations using a precision screwdriver. (Refer to Fig.2) (Remove the junction box B from D side.) 4) Remove all connectors mounted to the junction box B.
Refer to Fig.1) 3) Remove the junction box B (top) for all stations using a precision screwdriver. (Refer to Fig.2) (Remove the junction box B from D side.) 4) Remove all connectors mounted to the junction box B.
JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. *2) Labor Safety and Sanitation Law, etc. Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.