SI Unit for VQC/S0700 Series Valves ( EX500-Q 01 ) SI Unit for SV Series Valves ( EX500-S 01 ) M3 28: 4 pcs. ( Plus-minus slot round head screw ) Supply/exhaust block assembly Supply/exhaust block assembly 1.
K V 1 10 XLA S P1P2 XL XL Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2++1/Cn) when in series, and C=C1+C2++Cn, when in parallel.
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
No.ZB-OM00301 / ZB No.ZB-OM00301 2 9 12 13 15 16 16 V Assy 17 21 25 26 28 28 29 30 30 31 31 32 35 37 38 39 40 Assy 40 Assy 41 42 1 - No.ZB-OM00301 1) (ISO/IEC) (JIS) 2 *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.
Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2+...1/Cn) when in series, and C=C1+C2+...Cn, when in parallel.
Proper tightening torque (Nm) Tightening Torque for Piping Connection thread 7 to 9 12 to 14 22 to 24 28 to 30 Rc Rc Rc Rc 1 8 1 4 3 8 1 2 5. Piping to products When piping to a product, refer to the operation manual to avoid mistakes regarding the supply port, etc. Back page 5 5 Port Solenoid Valves Precautions 4 Be sure to read this before handling.
VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5
N x P (52) 28 20 U N (M6 x 1) C (5.1) 1 0.2 5 T-slot A 36: T-slot pitch 39 36 28 Body mounting reference plane 4H9 +0.030 0 6.5 27.5 Work piece mounting reference plane Refer to Cross section C-C.
(mm) Bore size A B C D F GA GB H MM NA NB NDh8 NN S Z 10 15 12 14 4 8 8 5 28 M4 x 0.7 12.5 9.5 8 0 0.022 M8 x 1.0 46 74 16 15 18.3 20 5 8 8 5 28 M5 x 0.8 12.5 9.5 10 0 0.022 M10 x 1.0 47 75 Single foot (L) CJ2YL Bore size Stroke Head cover port location Z Mounting nut Rod end nut Piping port 2 x M5 x 0.8 GB NN F GA Cover surface MM C D 0 0.3 LY LB B LH 0 0.3 B LX LT Piping port M5 x 0.8
D C B E1 L1 MM H A A1 R1 U1 d NDH10 NX 40 50, 63 80 100 I-04 I-05 I-08 I-10 NT-04 NT-05 NT-08 NT-10 21 25.4 22 8 69 22 24 55 M14 X 1.5 15.5 20 M14 X 1.5 12 16 +0.070 0 0.1 0.3 26 31.2 27 11 74 27 28 60 M18 X 1.5 15.5 20 M18 X 1.5 12 16 +0.070 0 0.1 0.3 31 37.0 32 13 91 37 36 71 M22 X 1.5 22.5 26 M22 X 1.5 18 28 +0.070 0 0.1 0.3 39 47.3 41 16 37 40 83 M26 X 1.5 24.5 28 M26 X 1.5 105 20 30
Table 3-10 Piping port size Description Port Recommended Recommended piping size tightening torque specifications Circulating fluid outlet port Rc1/2 28 to 30Nm 0.4MPa or more*2 Circulating fluid return port Rc1/2 28 to 30Nm 0.4MPa or more*2 Facility water inlet port *3 Rc3/8 22 to 24Nm 1.0MPa or more (Supply puressure: 0.3 to 0.5MPa) Facility water outlet port *3 Rc3/8 22 to 24Nm 1 For NPT
-COM3 19 -COM3 38 1) 28 N.C. -COM4 20 1) 9 N.C. -COM4 39 1) 29 N.C.
28 V, 80 mA Residual voltage: 2 V or less pe: 1 to 5 V e: Approx. 1 k B C A B C A Coil + + Max. 80 mA Residual voltage: 2 V or less Max. 28 V, 80 mA Residual voltage: 2 V or less pe: 1 to 5 V e: Approx. 1 k Black For supply valve (,+) Black For supply valve (,+) Coil White White Pilot valve for release Pilot valve for release LED (Red) Black LED For supply valve (,+) Pressure Switch for
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
2 port 3 port 28 17 20.5 28 20.5 17 20.5 28 20.5 VDW10 VDW20 VDW30 VDW200 VDW300 2 Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 How to Order Valves (Single Type) VD W 2 1 1 G 2 01 For water, air and vacuum Series Option 1 2 3 10 20 30 None Foot type bracket Nil F Note) Foot brackets are packed with valves.
Please order a seal kit with each part number of tube bore size. 6-2-10 5 Series CJP Pin Cylinder Single Acting, Single Return Basic Style CJPB 2-M5 x 0.8 2-M3 (For mounting auto switch) CJ1 CJP CJ2 6 = C2, 10 = C2.5 B' Without rod end thread (Width across flats) Auto switch Rod end nut (Refer to page 6-2-13.) CM2 15 = C3 CG1 Mounting nut (Refer to page 6-2-13.)
Please order a seal kit with each part number of tube bore size. 6-2-10 5 Series CJP Pin Cylinder Single Acting, Single Return Basic Style CJPB 2-M5 x 0.8 2-M3 (For mounting auto switch) CJ1 CJP CJ2 6 = C2, 10 = C2.5 B' Without rod end thread (Width across flats) Auto switch Rod end nut (Refer to page 6-2-13.) CM2 15 = C3 CG1 Mounting nut (Refer to page 6-2-13.)