Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: S (Centralized Lead Wire, Lead Wire Only), Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L3 (
Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L3
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port:
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port:
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 5, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L3 (
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L3 (
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 5, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge; 0.2 MPa)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator, Round
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 5, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)