Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: S (-90 kPa), SUP: N03 (Screw-in NPT 3/8), VAC: N04 (Screw-in NPT 1/2), EXH: N04 (Screw-in NPT 1/2), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: ø2.0mm, Vacuum Pressure: -90 kPa, SUP: Screw-in NPT 3/8, VAC: Screw-in NPT 1/2, EXH: Screw-in NPT 1/2, Accessories: w/o Bracket, w/o Silencer
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -66, Air Consumption Flow Rate(l/min): 196, Vacuum Port Connecting Port Shape: [Others] NPT1/2, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: NPT3/8, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C):
Made to Order: 20 (Copper-free/Fluorine-free), Body Size: 1/2, Handle-operated Type, Thread Type: NPT - Made to Order, Port Size: 1/2, Option: Silencer, Semi-standard: Display Units for Product Nameplate & Pressure Gauge: psi
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", IFW", "DIGITAL FLOW SWITCH
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", IFW", "DIGITAL FLOW SWITCH
Boosts local line pressure without requiring additional power, 2 to 4 times increase in pressure, Easy adjustment of output pressure, Improved performance over previous designs, BOOSTER REGULATOR 1/2, AIRLINE EQUIPMENT, VBA BOOSTER REGULATOR, FD, VBA 1/2INCH STANDARD (NPT), 20.53449 lb
Boosts local line pressure without requiring additional power, 2 to 4 times increase in pressure, Easy adjustment of output pressure, Improved performance over previous designs, BOOSTER REGULATOR 1/2, AIRLINE EQUIPMENT, VBA BOOSTER REGULATOR, FD, VBA 1/2INCH STANDARD (NPT), 18.95975 lb
Please contact us for the latest version.sales@ocaire.com, BOOSTER REGULATOR 1/2, AIRLINE EQUIPMENT, VBA BOOSTER REGULATOR, FD, VBA 1/2INCH STANDARD (NPT), 18.95975 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 1.04719 lb
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, FB, IF/PFA 1/2 INCH NPT VERSION, .52910 lb, ModelMeasured
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1?s, Rise time 1ns660 g3/8, 1/2
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns650 g1/2, 3/4
(50%)Karman vortex5 to 40 l/min0 to 1 MPa1.5 MPa0 to 90C (with no cavitation)?
Please contact us for the latest version.sales@ocaire.com, VBA 1/2INCH COPPER-FREE, AIRLINE EQUIPMENT, VBA BOOSTER REGULATOR, F6, VBA 1/2INCH COPPER-FREE, 20.2367 lb
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns470 g3/8, 1/2
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns470 g3/8, 1/2
Please contact us for the latest version.sales@ocaire.com, REMOTE SENSOR UNIT, WATER, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.33736 lb
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns470 g3/8, 1/2