SMC Corporation of America
Elite Part Number Search
Search Results "NCY2S40H-6000"

(Page 83) WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 1026 0x0402 0 R/W U16 100 Y Setting of OUT2 delay time at ON 10 ms increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 to 0x1770 (0 to 6000) 1028 0x0404 0 R/W dtL2 (Delay time at OFF) U16 0 Y Setting of OUT2 delay time at OFF 10 ms increment 0: 0.5 sec 1: 1.0 sec 2: 2.0

(Page 85) WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 1026 0x0402 0 R/W U16 100 Y Setting of OUT2 delay time at ON 10 ms increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 to 0x1770 (0 to 6000) 1028 0x0404 0 R/W dtL2 (Delay time at OFF) U16 0 Y Setting of OUT2 delay time at OFF 10 ms increment 0: 0.5 sec 1: 1.0 sec 2: 2.0

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours. Fig. 7-3 Check for water leakage from pump 7.2 Inspection and Cleaning HRS Series 7-6 HRX-OM-S004 Chapter 7 Control, Inspection and Cleaning 7.2.5 Inspection during winter season Keep the power supply ON for these functions. These functions do not start when the power is OFF.

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours.

800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800 17500 15 1000 20 2000 20 62 No.JXC-OMU0004-A 11. 11.1 [5m ] A B-1 2 A A-1 1 LE-CP-1 L B B-2 6 1 1.5m B A-2 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 S B B-6 9 B A-6 8 3 14.2 2 1 8 14) B1 A1 17.7 6 5 2 1 18

30 AP 1 1 1 1 Minimum command unit 1pulse AL 1 1 1 1 AD75P AM 1 1 1 1 Electronic gear AP 4000 20 6000 30 Minimum command unit 0.1 m AL 1000.0[ m] 1000.0[ m] 1000.0[ m] 1000.0[ m] AM 10 10 10 10 Note.

LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800

LEMB25 / LEMB32 LEMC25 / LEMC32 LEMH25 / LEMHT32 LEMH25 / LEMHT32 Speed [mm/s] Acceleration Speed Acceleration [mm/s2] [mm/s] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13

Recommended torque: 12 to 14 Nm. 231 MR Unit (Regulator with Mist Separator) AMR3000 to 6000 Replacement Procedure is P.448 Construction !1 t OUT IN u MC cartridge element Flow hole A Separation element i y Auto-drain type o !0 r Port size 1/4 Drain The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series AMR.

Filter P.402 AFM Modular Type Mist Separator P.402 AFD Modular Type Micro Mist Separator P.404 AR Modular Type Regulators P.412 AL Modular Type Lubricators P.420 AW Modular Type Filter Regulators P.431 ARG Modular Type Regulator with Built-in Pressure Gauge P.437 AWG Modular Type Filter Regulator with Built-in Pressure Gauge P.444 AR425 to 925 Pilot Operated Regulator P.448 AMR3000 to 6000

Description 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool Puller 57031-6000 307 Series LC6D Connection Examples Electrical wires Wiring numbers 0.5mm or larger (AWG18 to 20) 0.2mm or larger (shielding wire) (AWG18 to 24) For open collector output Series LC6D + 5VDC CW input 330 7 3 +24V + Receptacle side (female terminal insertion side) 24VDC CW 10 6 GND 330 2 CCW input

F.R.L. module combination When connecting to a modular F.R.L. combination (AC2000 to 6000), select one of the spacers, which are included. (Refer to page 6 for details.) However, modular combination with AC406 is not possible. Furthermore, connect soft start-up valves to the secondary side of the F.R.L. combination. 6.

Specimen CP Compressor IDF Refrigerated air dryer AFF Main line filter AM Mist separator Control panel Ozone resistance evaluation Models Operating frequency Conditions Series AS-F AS1000, 1400 AS120 to AS420 NBR Speed control valve Ozone concentration: 1ppm Inlet pressure: 0.7MPa Set pressure: 0.5MPa Ambient temperature: 23C ON 0.5 sec HNBR NBR OFF 0.5 sec AR1000 to 6000

Part Number Description: L-TYPE BRACKET NAC5/6000   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 100   Family Description: AC FRL COMBO   Class Code: 22   Part Code: 2   Reference Code:  B   Click here to report information errorImage shown may not match exact part number, L-TYPE BRACKET NAC5/6000, AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO SIZE RATING

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Weight (kg) 0.05 0.075 AC4000/5000/5500/6000 AR4000/5000/6000 AW4000 Applicable model C Part no.: 1305104-1A C1 Attachment: With cover ring assembly Part no.: 1305104-3A Note 1) Indicates the condition at the lower pressure limit.

PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to

Flow capacity (l/min (ANR)) Oil mist concentration at outlet side 300 750 1500 2200 3500 Filtration (m) Port size Rc Model AM150 AM250 AM350 AM450 AM550 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 Max. 1.0 mg/m3 (ANR) ( 0.8 ppm) , , , , , , , , , 1 1 0.3 1 2 3 4 3 4 1, 1 2 1 , 2 AM650 6000 AM850 12000 1 2 Can produce with auto drain type, drain piping type.

70C (Application of rated voltage) Temperature rise Power consumption DC Holding Inrush 5.6VA(50Hz), 5.0VA(60Hz) 12VA(50Hz), 10.5VA(60Hz) 3.4VA(50Hz), 2.3VA(60Hz) 7.5VA(50Hz), 6VA(60Hz) 1.8W 4.8W Apparent power AC Non-locking push style Others (Option) Manual override Non-locking push style 4.2-5 VNA Flow Characteristics Air How to Read The Graph In the sonic flow region: For a flow of 6000

Also, as a guide for periodically replacement, the operation hours is 6000 to 8000 hours. (normally 1 year) Note 2) Note 1) In the case of the HRG001/002, because the pump included in the unit is a magnet pump with no rotating shaft seal, it is not necessary to inspect the mechanical seal (rotating shaft seal).

Annual cost reduction effect [Calculation conditions] Electric power cost: 1.55 yen/m3 [Work model] Working hours: 6000 h (250 days/year) Supply pressure: 1.0 MPa Set pressure: 0.2 MPa Comparison between IR3200-A and the current IR3000 Comparison between IR1200-A/IR2200-A and the current IR1000/IR2000 300 300 Annual cost of power consumed by compressor [1000 yen/year] 250 250 When 20 units