Weight Auto Switch Internal Circuit D-F79 (g) D-F79 D-F7P D-J79 Auto switch model DC (+) Brown 13 11 13 0.5 Lead wire length (m) 57 50 57 3 Main circuit of switch Main circuit of switch OUT Black 92 81 92 5 DC () Blue Dimensions 3.5 mounting hole D-F7P Indicator light DC (+) Brown OUT Black DC () Blue D-J79 Most sensitive position OUT (+) Brown Main circuit of switch OUT () Blue 11-11-18
Weight Auto Switch Internal Circuit D-F79 (g) D-F79 D-F7P D-J79 Auto switch model DC (+) Brown 13 11 13 0.5 Lead wire length (m) 57 50 57 3 Main circuit of switch Main circuit of switch OUT Black 92 81 92 5 DC () Blue Dimensions 3.5 mounting hole D-F7P Indicator light DC (+) Brown OUT Black DC () Blue D-J79 Most sensitive position OUT (+) Brown Main circuit of switch OUT () Blue 12-13-12
Weight Auto Switch Internal Circuit D-F79 (g) D-F79 D-F7P D-J79 Auto switch model DC (+) Brown 13 11 13 0.5 Lead wire length (m) 57 50 57 3 Main circuit of switch Main circuit of switch OUT Black 92 81 92 5 DC () Blue Dimensions 3.5 mounting hole D-F7P Indicator light DC (+) Brown OUT Black DC () Blue D-J79 Most sensitive position OUT (+) Brown Main circuit of switch OUT () Blue 12-13-12
D-A33C/A34C Terminal conduit Tie-rod 5.3-18 D-A44C DIN terminal General purpose auto switch 5.3-19 D-A90/A93/A96 5.3-20 D-A90V/A93V/A96V 5.3-21 D-90/97 Grommet Direct 5.3-22 D-90A/93A 5.3-23 D-Z73/Z76/Z80 5.3-24 D-E73A/E76A/E80A 5.3-29 D-H7A1/H7A2/H7B Grommet 5.3-30 D-G59/G5P/K59 5.3-31 D-H7C Connector Band 5.3-32 D-G39/K39 Terminal conduit 5.3-33 D-G39A/K39A Solid state switch 5.3-34 D-F79/F7P
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
Yes 24V -0.076 ~ -0.05 12.7 1 50 1.9 PS-05 11.89 50, 63 44.2 D-A80C No 24V 24V -0.117 ~ -0.065 19.05 1.17 64 2.73 PS-08 17.89 80 56.2 D-A79W Yes 24V -0.117 ~ -0.065 22.23 1.17 72 2.73 PS-10 20.85 100 64.2 D-A90 2 Wire 24V/48V/100V AC/DC No D-A93 2 Wire Yes 24V 100V D-A96 3 Wire Yes 48V A C C E S S O R I E S S E R I E S N C Q 2 / C Q 2 J A M N U T D-F7NV D-F79 3 Wire NPN 5V, 12V D-F7PV D-F7P
DC Perpendicular In-line Perpendicular In-line 3 wire (Equivalent to NPN) A96V A96 A76H 5V IC A72H A72 200V Yes Grommet Reed switch Solid state switch A73 A73H 100V 12V A93V A93 Relay PLC 2 wire A90V A90 A80 A80H IC 100V 5V, 12V No 24V A73C 12V Yes No Connector A80C IC 5V, 12V 24V A79W Grommet Diagnosis indicator (2 color) Yes F7NV F79 IC 5V, 12V 3 wire (NPN) F9NV F9N 12V F7PV F7P
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.9195 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.9195 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.9195 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.9195 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.9195 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.9195 lb
IP65 protection rating Use with Series VQC1000/2000/4000 and SV1000/2000/3000/4000 valves.
Manifold/Plug-in Type Type 01C Circular Connector Type 01F D-sub Connector Series VFR2000/3000/4000/5000 Series VFR2000/3000/4000/5000 When multi-connector is used, mass-termination between power supply side and solenoid valve can be done.
5000 Flow rate L/min (ANR) 0 0 AC60-B Rc1 AC55-B Rc1 AC50-B Rc1 0.6 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 4000 6000 8000 2000 10 0 4000 6000 8000 2000 10 0 4000 6000 8000 2000 10 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) Pressure Characteristics (Representative
indication (2-color indication) Reed D-A73C Connector (Perpendicular) D-A80C Without indicator light D-A72H D-A73H, A76H Grommet (In-line) D-A80H Without indicator light 12 to 100 125 to 160 D-F7NV, F7PV, F7BV D-F7NWV, F7BWV Grommet (Perpendicular) Diagnostic indication (2-color indication) D-F7BAV Water resistant (2-color indication) D-J79C Connector (Perpendicular) Solid state D-F79, F7P
Lead wire length (m) Load voltage Rail mounting Indicator light Wiring (Output) Special function Type Electrical entry Pre-wired connector Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC Perpendicular In-line DC IC circuit 3-wire (NPN equivalent) A76H 5 V Reed switch Solid state switch Grommet A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C A79W F7NV F7PV F7B J79C F7NWV