Magnet: Built-in, Bore Size: 125mm, Stroke: 30mm, Body Option: Standard (Rod End Female Thread), Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Bore Size: 125mm, Stroke: 10mm, Body Option: Rod End Male Thread, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Bore Size: 125mm, Stroke: 175mm, Body Option: Standard (Rod End Female Thread), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Bore Size: 125mm, Stroke: 30mm, Body Option: Standard (Rod End Female Thread), Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2s mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125,? 140
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2s mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125,? 140
Model: MSQ, Precision: High Precision Type, Size: 10, Suffix: Shock Absorbers, Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Thread Type: -
Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.081, Format: Includes adjusting bolt, Size: 50, Switch: M9NA, Lead wire(m
Sensor Type: Non-Contact, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Wiring type: 3-wire type, Output Type: NPN type, Electrical entry direction: In-line, Lead wire length(m): 3, Connector Type: None
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,