Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 106 (1 1/16"), Stroke: 1600 (16"), Cushion: C (Urethane), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 125 (1 1/4"), Stroke: 0300 (3"), Cushion: C (Urethane), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 125 (1 1/4"), Stroke: 0600 (6"), Cushion: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 125 (1 1/4"), Stroke: 1600 (16"), Cushion: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 125 (1 1/4"), Stroke: 1800 (18"), Cushion: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 125 (1 1/4"), Stroke: 2000 (20"), Cushion: C (Urethane), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 3 pcs., Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 150 (1 1/2"), Stroke: 0400 (4"), Cushion: C (Urethane), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 150 (1 1/2"), Stroke: 1400 (14"), Cushion: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 150 (1 1/2"), Stroke: 1800 (18"), Cushion: C (Urethane), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 200 (2"), Stroke: 0800 (8"), Cushion: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

(Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel), Long Stroke Option: X142US (Long Stroke Option for U.S. Only)

98 5 30 345 75 40 133 368 98 345 368 Up to 1200 30 to 1200 0.2 stroke 9 3/4 106 5 30 388.5 409.5 75 40 141 409.5 106 388.5 Up to 1200 30 to 1200 0.2 stroke 3/4 111 448 85 45 153 466 115 452 470 Up to 998 30 to 1200 0.2 stroke 3/4 111 468 90 45 153 486 120 477 495 30 to 1200 0.17 stroke 1 141 579.5 105 55 176 595.5 790 Double Acting, Single Rod Series CLS Cylinder with Lock Axial foot type

Bore size (mm) Foot style, Rod side flange style ML1C 125, 140 160 Up to 1000 Up to 1000 Up to 1600 Up to 1200 Up to 1200 Up to 1600 Cylinder Stroke/Auto Switch Mounting on Cylinder Unit (Built-in Magnet) Refer to the minimum auto switch mounting stroke (page 774) for those with an auto switch.

400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] (1 Kg = 2.2 lbs) [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the value of y, z + A on the graph, please consult SMC.

) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1CW25 MY1CW25 (1000) (1000) (1000) (1000) MY1MW20 MY1MW20 30 30 (1000) (900) (1000) (900) (1000) (900) (1000) (900) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) (900) 20 20 1.

or less 1200 or less 1600 or less -XC27: Double clev!

Mounted directly to unlocking port Maximum value from range of 100 measured stopping positions 1600 or less 1000 or less 1000 or less 125, 140 1600 or less 1200 or less 1200 or less 160 2000 or less 1200 or less 180 Class 2 Pressure Vessel 2000 or less 1200 or less 200 A class 2 pressure vessel will be required for strokes exceeding those shown below. 2400 or less 1200 or less 250 Cylinder

1200 Specifications XC6 Standard model no.

Equipment 50 to 1000 D-m 50 to 1200 Minimum Strokes for Auto Switch Mounting Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection Operating Range Auto Switch Mounting Brackets: Part Nos.