(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).
Magnet: Built-in, Mounting: Basic, Bore Size: 7/16", Stroke: 10", Cushion: -, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 044 (7/16"), Stroke: 1000 (10")
st: , 1001 to 1500 st: JIS Symbol Standard Stroke Maximum manufacturable stroke (mm) Minimum stroke (1) Bore size (mm) Standard stroke (2) (Recommended) (mm) 20 150 Up to 700 25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
Auto Switches Common Specifications Type Solid state auto switch Reed auto switch Leakage current 3-wire: 100 A or less, 2-wire: 0.8 mA or less None Operating time 1ms or less3) 1.2 ms Impact resistance 1000 m/s2 4) 300 m/s2 Insulation resistance 50 M or more (500 VDC measured via megohmmeter) (Between lead wire and case) 1500 VAC for 1 minute1) 1000 VAC for 1 minute (Between lead wire and
st: , 1001 to 1500 st: JIS Symbol Standard Stroke Maximum manufacturable stroke (mm) Minimum stroke (1) Bore size (mm) Standard stroke (2) (Recommended) (mm) 20 150 Up to 700 25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
Load voltage Lead wire length (m) Note 1) Auto switch model Indicator light Special function Type Electrical entry Applicable load Wiring (output) 0.5 (Nil) 3 (L) 5 (Z) AC DC A90 5, 12V 24V IC circuit No 100V or less Reed switch 2 wire Relay, PLC A93 12V 100V Grommet Yes A96 3 wire (NPN equiv.) 5V IC circuit F9N 3 wire (NPN) Solid state switch F9P Relay, PLC 3 wire (PNP) 24V 12V
Type Model Electrical entry Features Without indicator light D-A90 D-A90V Grommet (In-line) Grommet (Perpendicular) Reed switch Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.
When bank 2 is selected Decimal no. 1 2 3 4 5 6 7 8 9 0 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 Output terminal 6 7 8 9 10 Preset no.
Lead wire length (mm) Load voltage Auto switch model Applicable bore size AC 20 to 63 80, 100 DC Indicator light Wiring (Output) Pre-wired connector Electrical entry Special function Type Applicable load 0.5 (Nil) 1 (M) 3 (L) 5 (Z) M9N M9P M9B M9NW M9PW M9BW A93 A90 B54 B64 G59 G5P K59 G59W G5PW K59W 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Solid state auto switch 2-wire
Type Model Electrical entry Features Without indicator light D-A90 D-A90V Grommet (In-line) Grommet (Perpendicular) Reed switch Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.
The maximum piston speed is: Auto switch operating range (mm) Load applied time (ms) V(mm/s)= 1000 Keep wiring as short as possible.
The maximum detectable piston speed is: Auto switch operating range (mm) _ Load operating time (ms) Operating current of load (OFF condition) > Leakage current V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).
Non-rotating accuracy when retracted and when no load is applied should be not more than the values shown in the table. 1000 Bore size [mm] Non-rotating accuracy MGPKM MGPKL 12 0.07 16 0.05 20 0.06 25 32 0.05 0.03 40 50 0.04 100 50 40 32 25 20 10 Load mass [kg] 16 12 1 0.1 0.01 100 1000 500 Max. speed [mm/s] 6 MGPK Series Replacement Parts: MGPKM, MGPKL Common 12 to 32 (101 mm stroke
(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod end 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Center Q1 = 0.019 + 0.040 + 0.019 + 0.040 = 0.118 L(ANR) End Center End Center Air consumed in the tubing is calculated using formula (2), as shown below. 0.5 0.1 Q2 = 12.6 x 1000 x x 10-6 = 0.063 L(ANR) An entire stroke includes two rotations from end to center where the air is consumed. Thus, the total air consumption Q of the rotary table and tubing is obtained as shown below.