Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 15 mm, Rotating Angle: 90 (90°), Vane Type: D (Double Vane), Connecting Port Location: Side Ported, Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 10 mm, Rotating Angle: 90 (90°), Vane Type: S (Single Vane), Connecting Port Location: Side Ported, Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in Magnet), Size: 10, Rotating Angle: 100 (100°), Vane Type: D (Double Vane), Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in Magnet), Size: 15, Rotating Angle: 100 (100°), Vane Type: D (Double Vane), Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Electrical Entry/Lead Wire Length: L (3m)

Part No. of Lead Wires with Connectors (Applicable only for connector type) Note 1) Lead wire length Z: 5 m Applicable auto switches Reed auto switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state auto switch: Manufactured upon receipt of order as standard.

Note 1) Lead wire length Z: Auto switches applicable for 5m Reed switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: All models are produced upon receipt of order (standard procedure). However, this does not include D-F9, F9V and F7WV.

Electrical entry Indicator Lead wire Applicable load 3 (L) 5 (Z) AC DC Parallel code 97 12V Yes 24V 93A Cab tire 12V 100V Relay PLC Grommet 2 wire Parallel code 5V 12V 5V 12V 24 V or less 100 V or less 90 IC circuit No 24V 90A Cab tire * Impossible to mount the auto switch on the clevis and trunnion styles. 1.2-1 Pin Cylinder/Single Acting Spring Return Series CJP 6, 10, 15 How to Order A

Applicable models: D-A73, A73H, A73C, C73, C73C, D-97, 93A, A93, A93V, D-A33A, A34A, A44A, D-B53, B54 2) However, in the case of a 2 color indicator type auto switch (D-A79W, B59W), note that the switch will be in a normally ON condition if connections are reversed. Never carry a cylinder by its lead wires.

Magnet: D (Built-in Magnet), Mounting: F (Flange), Size: 10, Rotating Angle: 180 (Single Vane), Vane: S (Single), Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.

Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.

10mm 16 16mm 20 20mm 25 25mm 32 32mm Stroke allowance +1.0 0 Thread tolerance JIS 2 Class Rod tip screw : Yes or No Yes, No (Pad Direct Mounting) S T R O K E Mounting Basic Type 5,10,15,20,25,30 10,16mm only 5,10,15,20,25,30,40,50 20,25,32mm only 10 16 20 32 25 Non-rotating piston rod accuracy 0.8 .0.5 A U T O S W I T C H E S Reed D-90 (DC Only) D-97 (w/LED, DC Only) A-90A (AC or DC) D-93A

R802. 90A D-R731, R732 D-90 l B u e D-93A I I !

Part No. of Lead Wires with Connectors (Applicable only for connector type) Note 1) Lead wire length Z: 5 m Applicable auto switches Reed auto switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state auto switch: Manufactured upon receipt of order as standard. Note 2) The standard lead wire length for trimmer auto switches is 3 m.

v v IC circuit 3-wire (PNP) S9PV S9P V V v v 2-wire 12 V T99V T99 V V v v Solid state auto switch Oilproof heavy-duty cord Yes For 10, 15 Relay, PLC Grommet 24 V 5 V, 12 V 5 V, 12 V, 24 V 90 Vinyl parallel cord V V V IC circuit 5 V, 12 V, 100 V 5 V, 12 V, 24 V, 100 V 90A Oilproof heavy-duty cord V V V Reed auto switch No 2-wire Yes 97 Vinyl parallel cord V V V 100 V 93A

Load voltage Lead wire length (m) Indicator light Yes Yes Yes No No Applicable model Type Special function Wiring (Output) Auto switch model Lead wire type Pre-wired connector Electrical entry Applicable load 0.5 (Nil) 3 (L) None (N) 5 (Z) DC AC Perpendicular In-line S99V S9PV T99V S99 S9P T99 90 90A 97 93A S79 S7P T79 T79C R73 R73C R80 R80C 3-wire (NPN) Solid state switch 5 V, 12 V IC circuit

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

Free mount type Series CRBU2 Single/Double type D141 Series CDRB2/CDRBU2/CRB1 With Auto Switch Applicable Auto Switch Applicable series Auto switch model Electrical entry D-90, D-90A Reed switch Grommet, 2-wire D-97, D-93A CDRB2BW10/15 CDRBU2W10/15 D-S99, D-S99V Grommet, 3-wire (NPN) Solid state switch D-S9P, D-S9PV Grommet, 3-wire (PNP) Grommet, 2-wire D-T99, D-T99V Grommet, 2-wire D-R73