st: , 1001 to 1500 st: Stroke length tolerance JIS Symbol Standard Stroke Maximum manufacturable stroke (mm) Minimum stroke (1) Bore size (mm) Standard stroke (2) (Recommended) (mm) 20 150 Up to 700 25 150 Up to 700 1500 150 32 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Bore sizes 25 to 100 are available for the D-P3DW. Since there are other applicable auto switches than listed, refer to page 22 for details.
st: , 1001 to 1500 st: +1.8 0 Stroke length tolerance Mounting Basic style, Axial foot style, Rod/Head side flange style REF Stroke (mm) Max. stroke Bore size (mm) Standard stroke (2) Minimum stroke (Recommended) (1) 20 1500 up to 700 250 25 1500 up to 700 250 Made to Order (Refer to page 1882 for details.) 32 1500 up to 1000 250 40 1500 up to 1000 250 Symbol Specification Made of stainless
Auto Switch Common Specifications Solid state switch Type Reed switch 3-wire: 100 A or less 2-wire: 0.8 mA or less Leakage current None Operating time 1 ms or less 1.2 ms 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 VDC Mega (between lead wire and case) Insulation resistance 1000 VAC for 1 minute 1500 VAC for 1 minute Withstand voltage (between lead wire and case) (between lead
Magnet: D (Built-in), Type: W (Double Rod), Mounting: U (Front Trunnion), Cushion: A (Air Cushion), Bore Size: 50 (2 Inch), Stroke: 1000 (10 Inch)
Magnet: Built-in, Type: Double Rod, Mounting: Front Trunnion, Cushion: Air Cushion, Bore Size: 2 Inch, Stroke: 10 Inch, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to pages 837 and 838 for the details of solid state auto switch with pre-wired connector. Auto switches are shipped together, (but not assembled).
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are applicable auto switches other than listed, refer to page 23 for details. For details about auto switches with pre-wired connector, refer to Best Pneumatics No. 2. D-A9, M9, M9W, M9AL are shipped together (but not assembled).
RS2H50, 63, 80 1.0 0.9 RS2H63 RS2H50 0.8 RS2H80 Operating pressure P [MPa] 0.7 0.6 0.5 0.4 0.3 0.2 0.1 1000 2000 3000 4000 0 5000 Lateral load F [N] Even after the impact of the carried object is absorbed, lateral load acts on the stopper cylinder due to the friction generated between the conveyor and the carried object.
Auto switch models D-A9 and D-APV cannot be mounted on CHD2E, CHD2H of all bore sizes and CHD2F32. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are applicable auto switches other than listed, refer to page 380 for details. For details about auto switches with pre-wired connector, refer to pages 474 and 475.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL Since there are other applicable auto switches than listed above, refer to page 361 for details. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649. The D-A9ll/M9lll auto switches are shipped together, (but not assembled).
. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ * Since there are other applicable auto switches than listed above, refer to page 146 for details. * The D-A9l/M9l/M9lW/M9lA auto switches are shipped together, but not assembled.
CA2 20 1000 CS1 25 1500 25, 50, 75, 100, 125, 150 200, 250, 300 Symbol Specifications 32 2000 XA Change of rod end shape CS2 40 2000 XB6 Heat resistant cylinder (150 ) XB7 Cold resistant cylinder Note 1) Other intermediate strokes can be manufactured upon receipt of order. Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are not used.)
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order. The D-G5/K5/B5/B6 types cannot be mounted on the bore size 40. D-X Since there are other applicable auto switches than listed above, refer to page 376 for details.
Determination of load's kinetic energy (E) E > Es E Es Determination of bore size Review of larger bore size E = m E 2 a ( ) 2 = (Refer to page 1548.) 1000 P Ps P > Ps Determination of pressure for intermediate stop (p) (Refer to page 1548.)
*Lead wire length symbols 0.5m Nil (Example) M9NW 1m M (Example) M9NWM 3m L (Example) M9NWL 5m Z (Example) M9NWZ *Auto switches matked with a "" are produced upon receipt of orders. *Auto switches are shipped together, (but not assembled). -18- Specifications Table 1.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Bore sizes 32 to 63 are available for the D-P3DWA. Since there are other applicable auto switches than listed, refer to page 515 for details.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. For D-P3DWA, 32 to 63 are available. DSince there are other applicable auto switches than listed, refer to page 400 for details.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 26 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785 of Best Pneumatics No. 3.