The D-A9 model cannot be mounted on 50. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For 32 to 100, there are applicable auto switches other than listed. Refer to page 273 for details. For details about auto switches with pre-wired connector, refer to pages 474 and 475.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Solid state auto switches marked are produced upon receipt of order. Since there are applicable auto switches other than listed, refer to page 258 for details.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Besides the models in the above table, there are some other auto switches that are applicable.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 23 for details. For details about auto switches with pre-wired connector, refer to the Best Pneumatics No. 3. For the D-P3DWA, refer to the WEB catalog.
switch 2-wire 12 V Relay, PLC Grommet Yes 24 V 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 12 V Yes No Yes No 100 V Reed auto switch Relay, PLC IC circuit 100 V or less Grommet 24 V 2-wire 12 V 100 V, 200 V 200 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ
Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Since there are applicable auto switches other than those listed above, refer to page 42 for details.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to pages 837 and 838 for the details of solid state auto switch with pre-wired connector.
(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.
Symbol Nil None A B C Changed part XVD Without indicator With indicator Without indicator With indicator XLF100-30-1 XLF100A-30-1 XLF100-30-1H XLF100A-30-1H 5 to 60C 8-1 8-2 XGT 8-1 5 to 150C 8-2 Temperature specifications Symbol Nil 5 to 60C 5 to 150C H0 CYV Temperature Seal material: Same as the seal materials of How to Order Valve Same as How to Order Specifications Valve type Shaft seal
Nominal filtration rating: 0.01 m [Filtration efficiency: 99.9%] Oil mist density at outlet: Max. 0.1 mg/m3 (ANR) [0.08 ppm] 150C 1/8, 1/4 200 250C 1/4, 3/8 500 350C 3/8, 1/2 1,000 Piping support type 450C AMH 1/2, 3/4 2,000 550C 3/4, 1 3,700 1, 1 1/2 650 6,000 1 1/2, 2 850 12,000 AMH150C to 550C AMH650/850 150C 1/8, 1/4 200 Dust filtration, Oil mist adsorption Dust filtration, Oil mist adsorption
) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Bore size Stroke How to Order Standard model no.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm SMC test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm P/A test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.
) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Bore size Stroke How to Order Standard model no.
(Except swivel elbow) Fluid temperature: 65 to 260C (Swivel elbow: 5 to 150C) Grease-free, Can be used with steam. Applicable tubing O.D.
(Except swivel elbow) Fluid temperature 5 to 150C 65 to 260C (Swivel elbow: 5 to 150C) Grease-free/Can be used with steam. Applicable tube Metric size, Inch size Metric size, Inch size Connection thread R, Rc, NPT M, R, Rc, UNF, NPT Certified to meet current Food Sanitation Law standards. (Component materials have met apparatuses and container-packages standards.)
(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.
Bore size (mm) Effective thread length Width across flats A D H K MM W ZZ 40 50 63 80 100 32 37 37 37 47 18 22 22 26 31 35 40 40 40 50 20 25 25 30 36 58 71 71 72 85 7 11 11 11 15 M18 x 1.5 9 9 9 0 0 153 172 183 205 228 M22 x 1.5 M22 x 1.5 M26 x 1.5 A B M30 x 1.5 With heavy duty scraper -XC4 Heat resistant (150C) -XB6 4 2 The cylinder seals are changed to a heat resistance (to 150C) material
MB XB6 With heavy duty scraper Specifications Heat resistant cylinder (150C) Specifications Action Cushion Wiper ring Double acting, Single Double rod Air cushion/Rubber bumper SCB scraper Double acting, Single/Double rod 10C to 150C Unavailable for mounting Air cushion Fluorine rubber Heat resistant grease Action Ambient temp.
) XB6 2 5 The cylinder seals are changed to a heat resistant (to 150C) material, for use under severe conditions which exceed the standard specifications of 10C to +70C.