Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600
Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
*Lead wire length symbols: 20in (0.5 m) Nil (Example) M9NW 39in (1 m) M M9NWM 118in (3 m) L M9NWL 197in (5 m) Z M9NWZ 1
Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 25 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 32 to 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Made to Order: Individual Specications (For details, refer to page 491.)
Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. For D-P3DWA, 32 to 63 are available. DSince there are other applicable auto switches than listed, refer to page 400 for details.
M9PAV M9BAV 12V 3-wire (NPN) IC circuit 5V,12V 3-wire (PNP) Solid state switch 2-wire 12V 3-wire (NPN) IC circuit 5V,12V Relay, PLC Diagnosis (2-color indication) Grommet Yes 24V 3-wire (PNP) 2-wire 12V 3-wire (NPN) IC circuit 5V,12V Water resistant (2-color indication) 3-wire (PNP) 2-wire Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL
-X1247 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500 600, 700, 800 20, 25 32, 40, 50 63, 80 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500, 600 700, 800, 900,1000 Intermediate strokes and strokes shorter than 75 mm are also available.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.
Relationship between Number of Needle Rotations and Piston Speed 32, 40 50, 63 800 800 32 32 50 700 700 600 600 63 Piston speed (mm/s) Piston speed (mm/s) 40 40 500 500 50 400 400 63 300 300 200 200 100 100 1 0 1 2 3 4 5 6 0 0 1 2 3 4 5 6 7 8 9 10 7 Fully opened Without restrictor Without restrictor Fully opened Number of restrictors needle rotations Number of restrictors needle rotations
100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.
Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specifications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.
400 63 300 300 200 200 100 100 1 0 1 2 3 4 5 6 7 Fully opened 0 0 1 2 3 4 5 6 7 8 9 10 Without restrictor Without restrictor Number of restrictors needle rotations Fully opened Number of restrictors needle rotations Restrictor: ASN2-M5 Pressure: 0.5 MPa Mounting orientation: Horizontal, No-load, Piston extended The above piston speed is for reference purpose only.
moment around the Z1 axis of A part of attachment kgm2 Distance between Z and Z1 axis mm IZ1 Inertia moment around the Z2 axis of B part of attachment kgm2 Distance between Z and Z2 axis mm IZ2 Allowable Range of Moment of Inertia of Attachment MHY2-10D MHW2-20D MHW2-50D 1.2 6 600 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 500 1.0 4 400
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to pages 837 and 838 for the details of solid state auto switch with pre-wired connector. Auto switches are shipped together, (but not assembled).
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to page 28 for applicable auto switches other than listed above. For details about auto switches with pre-wired connector, refer to pages 1192 and 1193. Auto switches are shipped together, (but not assembled).
IC circuit 5 V, 12 V Solid state switch Reed switch 12 V Relay, PLC Yes Yes No Grommet 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V IC circuit 3-wire (NPN equivalent) A96V A96 5 V 24 V Grommet A93V A90V A93 A90 Relay, PLC 100 V 2-wire 12 V IC circuit 100 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL
0.4 MPa Lateral load F (N) Lateral load F (N) 50 RSQ 0.2 MPa 20 Point of application L 0.3 MPa 40 0.2 MPa RSG 30 Lateral load F RS 10 20 MI 10 80 70 30 40 50 60 30 60 70 50 40 20 Point of application L (mm) Point of application L (mm) MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 200 320 0.7 MPa 500 0.7 MPa 280 0.2 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.7 MPa 0.6 MPa 0.6 MPa 160 0.5 MPa 240 0.5 MPa 400