Specification: 11 (Clean Type, Vacuum Suction), Bore Size: Ø16, Stroke: 30mm, Adjuster: C (Metal Stopper), Magnet: W/Magnet and Rail, Auto Switch: M9N (Solid State, Gen. Purpose, 3 Wire NPN, Horizontal)
Specification: Clean Type, Vacuum Suction, Bore Size: Ø16, Stroke: 30mm, Adjuster: Metal Stopper, Magnet: W/Magnet and Rail, Auto Switch: Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 3m, Number: -
Specification: Clean Type, Vacuum Suction, Bore Size: Ø16, Stroke: 30mm, Adjuster: Metal Stopper, Magnet: W/Magnet and Rail, Auto Switch: Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: -, Number: -
L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.
L (Example) A93L 5m . Z (Example) F9NWZ Solid state auto switches with a "" symbol are produced upon receipt of order.
NPN) F9NV F9N 3 wire(NPN) Diagnostic indication (2 color) F9PV F9P 3 wire(PNP) P.5.3-39 F9BV F9B 2 wire Relay, PLC 24V Yes Grommet 12V F9NWV F9NW 3 wire(NPN) F9PWV F9PW P.5.3-66 3 wire(PNP) F9BWV F9BW 2 wire PLC: Programmable Logic Controller *Lead wire length 0.5m (Ex.) 3m L A93 A93L Specifications Specifications are same as the standard style.
A93 A93L F9NWZ (Example) (Example) (Example) 13 Rotary Table Series MSQ Specifications 10 20 30 50 70 100 200 Size Air (non-lube) Fluid Maximum operating pressure Minimum operating pressure 1MPa With adjustment bolt Note 1) 0.6MPa With internal shock absorber 0.1MPa Basic type 0.2MPa 0.1MPa High precision type 0 to 60C (with no condensation) Ambient and fluid temperature Rubber bumper With
L A93L Note) Refer to P. 177 to 179 for further information of auto switch. PLC: Programmable Logic Controller Specifications Specifications are same as the standard type.
Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.
Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) M9NZ Refer to page 8-28-27 for additional details and applicable auto switches other than the above types.
White 1 1 [C] Brown Brown 20 Yellow 2 2 Black Blue 22 PM Orange C3 CM 3 24 FAN 3 Blue Blue Blue 4 Brown 18 Red 5 [G4] Yellow/Green Yellow/Green [G3] Option DM (CN6) 2/3 (CN5) 3/3 Red Brown 5 1 2 Black 5 LS1 Red Blue 6 6 Black Red Brown 5 7 Yellow/Green LS2 4 8 Black Red Blue Black [G4] DI solenoid valve 1 Red Brown 15 FWD CM Black SVDI Blue 16 2 12 11 Option DM IV Water leakage detector 30C
BL Option U other than T1/Z/Z1 (CN2) (CN1) 1 1 3 3 2 2 4 4 3 2 1 3 2 1 4 4 2 1 1 3 2 1 6 8 3 5 7 2 4 2 1 1 3 2 USB Board PCB4 Display Board PCB3 BK BR RD RD RD RD BL BK BK RD RD WH Not connected at option Z 24COM AOUT +24V + OUT (CN1) 3 6 2 5 4 1 BR BR BL BL Option DM DI Sensor Level Switch Level Switch Water Leak Sensor BL BR WLS LS1 LS2 Solenoid Valve DI SVDI Option DM BL 11 FWD 12 CM 30C
degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig
ID20 ID30 ID40 ID60 Model 80 155 330 780 20 37 85 195 100 192 415 975 Recycled air flow rate Note) (L/min (ANR) Outlet air flow rate (L/min (ANR) Inlet air flow rate (L/min (ANR) Port size (Nominal size B) Weight (kg) 1 4 1 2 1 2 3 4 7 8.5 18.5 25 Supply dry air with a low dew point below 30C. Compact and lightweight without heater and electric control board.
Part Standard Replacement Operating Conditions Period Cooling Fan 4 to 5 years Smoothing Capacitor 7 to 8 years Surrounding Air Temperature: Annual average of 30C Other Aluminum Electrolytic Capacitor 5 years Load Factor: 80% max. Operation Rate: 20 hours/day max.
Part Standard Replacement Operating Conditions Period Cooling Fan 4 to 5 years Smoothing Capacitor 7 to 8 years Surrounding Air Temperature: Annual average of 30C Other Aluminum Electrolytic Capacitor 5 years Load Factor: 80% max. Operation Rate: 20 hours/day max.
(Refer to the instruction manual for details on the cleaning.) 42 47 49.5 40 39.5 43 44.5 34.5 35.5 36 38 40 41.5 10 12000 14000 HAW75 15000 18000 20 45 48.5 52 45 39 40 42.5 41 43 45.5 34.5 35.5 36 HAW110 Conditions: Air pressure 0.7 MPa, Cooling water temperature 30C. Inlet air temperature 50C is saturated air.
Cool from 30C (303 K) to 20C (293 K). : Tap water Density g: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath * Refer to the information shown below for the typical physical property values by circulating fluid.
1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 * Shown above are reference values.
1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.