20C (68F) bend the tubing into a U shape.
Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.
factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] V After 15 minutes, cool 32C down to 20C.
After 15 minutes, cool 32C down to 20C.
O When the ambient temperature is 20C 5C and rated voltage is applied. P Coil change from AC to DC or DC to AC is impossible because the iron core shapes are different.
(at 20C) Data 10-12-9 9 Series CEP1 Proper Auto Switch Mounting Position Weight (Without mounting bracket/connector) (kg) Regarding dimensions for the proper auto switch mounting position (at stroke end), refer to page 1012-16.
After 15 minutes, cool 32C down to 20C. HRL200-A Precautions on Cooling Capacity Calculation 1. Heating capacity When the circulating fluid temperature is set above room temperature, it needs to be heated by the thermo-chiller. The heating capacity depends on the circulating fluid temperature.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) For details, please contact SMC.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
20C (68F) bend the tubing into a U shape.
A 10 () (+) White Black Conductor resistance /km, 20C Station 10 65 or less SOL. B 23 () (+) Gray Red 11 () (+) White Red SOL. A Withstand pressure V, 1 minute, AC Station 11 1000 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Insulation resistance M/km, 20C Station 12 5 or less SOL. B 25 () (+) White None Note) The minimum bending radius for D-sub connector cables is 20mm.
Connector structure ZSE/ISE40, 80 Series Available Mounting Options Series IP40 IP65 20 20A 20B(-L) 20C With waterproof cover (20B, 20C) Lead wire Mounting Available Mounting Options Series Bracket A Bracket B Bracket C Panel mount 20 20A 20B(-L) 20C The bracket configuration allows for mounting in four orientations.
capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] HED V After 15 minutes, cool 32C down to 20C.
JIS symbol 1/8, 5/32 3/16, 1/4 3/8 5/16 3/16, 1/4 1/4 3/16 1/4, 5/16 1/2 Inch sizes 3/8 5/32 Flow rate l/min (ANR) {Nl/min} 920 660 230 420 1390 290 460 1050 100 130 Controlled (Free) Effective area mm flow 14 10 3.5 6.5 21 4.5 7 16 2 1.5 1l/min=0.035SCFM 18mm2=1Cv Note 1) Flow rate values are at a pressure of 0.5MPa (72.5psi) and temperature of 20C (68F).
(Coil temperature: 20C, at rated voltage) SY3000 SY7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Type of actuation Without light/surge voltage suppressor 12 or less Type of actuation Without light/surge voltage suppressor 31 or less Type R, U Type S, Z 12 or less
Low temperature operation 1) The valve can be used in an ambient temperature of between 10 to 20C.
Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.
Flow rate conversion PF2 NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3 kPa Standard state: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these states.
M km, 20C 5m VVZS3000-21A-3 x 24AWG * For other commercial connectors, use a 25-pole female connector made in conformity with MIL-C-24308.