Specifications Suction flow rate of vacuum suction type (Reference values) Bore size (mm) Item 20/25/32/40/50/63/80/100 1.5MPa 1.0MPa 0.05MPa Proof pressure Maximum operating pressure Minimum operating pressure Bore size Suction flow rate l/min (ANR) 20/25/32/40 50/63/80/100 10 20 Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Ambient and fluid temperature 10-/

Trace the arrow mark , starting with the point A at the pressure dew point 10C to find the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark , starting with the point B to find the intersection C at the atmospheric pressure dew point. 3.

Trace the arrow mark , starting from point A at a pressure dew point of 10C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. Trace the arrow mark , starting from point B to obtain the intersection C at the dew point under atmospheric pressure.

L SPECIFICATIONS Fluid Air S T D S T R O K E/H U N D R E D T H S O F A N I N C H Proof Pressure 1MPa / 145 PSI 6 (1/4) 050, 100, 150, 200 10 (3/8) 050. 100. 150, 200, 300, 400, 500, 600 16 (5/8) 050, 100, 150, 200, 300, 400, 500, 600, 700, 800 MaxImum Operating Pressure 0.7MPa / 100 PSI 6 0.1MPa / 17 PSI Minimum Operating Pressure 10, 16 0.05MPa / 8.5 PSI Ambient and Fluid Temperature -10C

Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 50F (10C) or less. Note 2) Use fluid in condition below as the circulating fluid.

Fluid and fluid temperature Air: 10 to 60C (Dew point temperature: 10C or less) Withstand pressure 2.0 MPa Max. system pressure 1.0 MPa Ambient temperature 20 to 60C Valve leakage*1/External leakage*1 Air 1 cm3/min (ANR) or less Mounting orientation Unrestricted Enclosure*2 IP67 (IP65 for the DIN terminal) Standards*3 CE/UKCA Operating environment Location without the presence of corrosive

) Facility water: 50F (10C) 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) HED007 60 80 100 120 140 F 40 2800 2400 Facility water: 95F (35C) Heating capacity (W) Facility water: 77F (25C) 2000 1600 1200 Facility water: 50F (10C) 800 400 0 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) 178 Chemical Thermo-con

(including four M10 bolts)9 Accessories Weight (dry state) kg Approx. 124 1 Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less.

(including 4 M10 bolts) Note 10) Weight (dry state) kg Approx. 130 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less. Note 2) Use fluid in condition below as the circulating fluid.

Refrigerant AFF AM UL certified product Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (IDFB4E to 75E) AMD Power supply voltage: Single-phase 115 VAC (60 Hz) 230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C

to 70C With auto switch: 10C to 60C (With no condensation) Proof pressure Max. operating pressure Min. operating pressure Mounting Bracket / Part No.

Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item Bore size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 20 25 32 40 50 63 80 100 10 20 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Stroke

Condition Condition Inlet air temperature 40C Inlet air temperature 55C Outlet air pressure dew point 10C Outlet air pressure dew point 10C Ambient temperature 35C Ambient temperature 35C Inlet air pressure 0.5MPa Inlet air pressure 0.7MPa Air flow 1200 l/min (ANR) Air flow 350 l/min (ANR) Power supply frequency 60Hz Power supply frequency 50Hz A = 0.85 based on conditions , and B-1 = 0.95

At the same ozone concentration of 1.1ppm, approximately 25% of the ozone still remains in the circuit as measured at point downstream of the mist separator (AM) at an atmospheric dew point of 10C. When the atmospheric dew point is 17C, approximately 45% of the ozone still remains.

Auto switches are shipped together but not assembled. 526 Free Mount Cylinder with Air Cushion Series CU Specifications Type Fluid Proof pressure Maximum operating pressure Minimum operating pressure Pneumatic (Non-lube) Air 1.0 MPa 0.7 MPa 0.08 MPa Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C (No freezing) Male thread + 1.0 0 50 to 500 mm/s Ambient and fluid

to 70C With auto switch : 10C to 60C CB Air cushion Cushion CV/MVG to 250 : +1.0, 251 to 1000 : +1.4, 1001 to 1500 : +1.8 0 0 0 Allowable stroke tolerance CXW Basic, Axial foot, Front flange, Center trunnion Mounting bracket CXS * Load is limited by piston speed, mounting direction, operating pressure at locking.

Lead wire length symbols: 0.5 m Nil (Example) M9NWV 1 m M (Example) M9NWVM 3 m L (Example) M9NWVL 5 m Z (Example) M9NWVZ D-X 427 A CK1 Series Specifications Bore size (mm) 50 40 63 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C Ambient and fluid temperature Piston speed 50

. * Air purification rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more Bernoulli type XT661 X321 4C Outer body diameter: 4C 39 mm 6C 59 mm 8C 79 mm 10C 99 mm 4C 6C 8C 10C 120E 150E Bernoulli type Outer body diameter (mm) 39 59 79 99 l120 l150 Piping port size M5 x 0.8 Rc 1/8 XT661 X322 120E Fluid Air* Operating pressure 0.01 to 0.4 MPa Body size: l Proof pressure 0.6 MPa Ambient

DC AC 0.5 1 3 5 () (M) (L) (Z) M9NV M9N IC 3 NPN 5V 3 PNP M9PV M9P 12V 2 12V M9BV M9B M9NWV M9NV IC 3 PNP M9PWV M9PW 3 NPN 5V 12V 2 2 12V M9BWV M9BW 24V M9NAV M9NA IC 3 PNP M9PAV M9PA PLC 3 NPN 5V 12V 2 2 12V M9BAV M9BA 2 2 P3DW 3 NPN A96V A96 IC 12V 100V A93V A93 2 24V 5V 100V A90V A90 IC PLC 12V 0.5m D-M9N M 1m D-M9NM L 3m D-M9NL Z 5m D-M9NZ 1 17 - 7-2. -1516

Lead wire length (m) Flexible lead wire (-61) Applicable load 0.5 (Nil) 3 (L) 5 (Z) DC AC Special function Electrical entry Indicator light Wiring (Output) Perpendicular In-line Type Grommet Yes 3-wire (NPN) 3-wire (PNP) 2-wire 24 V M9NV M9PV M9BV M9N M9P M9B Relay PLC Standard 12 V Solid state switch Lead wire length symbols: 0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ