Symbol: N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: None, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -
Symbol: N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: None, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
SI unit output and coil numbering
8 P . 5-6-12 P . 5-6-20 P . 5-6-41 P . 5-6-35 P . 5-6-48 P . 5-6-54 P . 5-6-32 P . 5-6-26 Effective area (mm2) Number of ports 1 2, 3 Poppet 2.5 2, 3 Poppet 19 2, 3 Poppet 7 3 Balanced poppet 10.8 5 Rubber spool 18 5 Metal spool 9.9 5 Metal spool 18 5 Rubber spool 6 3 Balanced poppet Function Dual pressure is available only on external pilot. 5-6-2 5-6-3 2 Series VM Transmitters Effective
Size Symbol 2 2 2 3 3 4 4 5 5 6 6 A B C A B A B A B A B 2 2 3 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" LVC LVA LVH LVD With reducer Basic size LVQ Note 1) Select a fitting the same
mA), Holding 1.26 VA (6 mA) 200 VAC 5(R1) 1(P) 3(R2) Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA) 220 VAC 4-position dual 3-port valve Note) 2(B) 4(A) VQZ (B) Note 1) Use dry air to prevent condensation when operating at low temperatures.
(Except for L kit) Note 6) Indicate R for the valve with external pilot.
mA), Holding 1.26 VA (6 mA) 200 VAC Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.
mA), Holding 1.26 VA (6 mA) 200 VAC Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.
8 P . 5-6-12 P . 5-6-20 P . 5-6-41 P . 5-6-35 P . 5-6-48 P . 5-6-54 P . 5-6-32 P . 5-6-26 Effective area (mm2) Number of ports 1 2, 3 Poppet 2.5 2, 3 Poppet 19 2, 3 Poppet 7 3 Balanced poppet 10.8 5 Rubber spool 18 5 Metal spool 9.9 5 Metal spool 18 5 Rubber spool 6 3 Balanced poppet Function Dual pressure is available only on external pilot. 5-6-2 5-6-3 2 Series VM Transmitters Effective
Air release valve Air release valve 1 station 1 station Control unit Control unit 1 station 1 station Pressure switch Pressure switch Connector terminal no. 2 station 2 station 2 stations 2 stations 3 stations 3 stations 3 stations 3 stations 4 stations 4 stations 4 stations 4 stations 5 stations 5 stations 5 stations 5 stations 6 stations 6 stations 6 stations 6 stations Connector terminal
8.2 16 18 20.5 16 16 18 20.5 17 32 35 39 31.5 32 35 39 3 6 8 10 5 6 8.5 10 When a block disk is concurrently ordered by specifying on the manifold specification sheet, etc., a label will be stuck on the position where block disk is mounted.
-SPN2A EX245-SPN3A (WLH)mm 85127.589.5 85147.789.5 465 g 540 g PBT 8 128 64 IO-Link 32 (US1 ) 300 mA 200 mA (US1/US2) XD1/XD2 16 A 6 A DC24 V 20%/15% US1 DC19.2 V 6 A DC24 V 20%/15% US2 4 A 1.2 V(DC24 V ) US1-US2 JSY JSY300JSY5000 SY SY3000SY5000 VQC VQC2000VQC4000 32 DC24 V,1 W PNP() 7/8 5 )10A EX245-SPN3A 4AXD1/XD2 6A 37 No.EX-OMW0014CN-A . 6-2 () EX245