Buffer stroke 25 50 75 100 40 50 63 80 100 125 Series ZPT ZPX Pad Material and Characteristics : Little or no influence : Can be used depending on conditions X: Not suitable Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Solvent resistance (Benzene, toluene) Durometer HS (5C) Base resistance Acid resistance Abrasion resistance Ozone resistance

Take measures to prevent freezing at temperature below 5C, since moisture in circuits may freeze and cause damage to seals and lead to malfunctions. 5. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. Cushion Caution 1.

Take measures to prevent freezing, since moisture in circuits can be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Best Pneumatics vol.4 catalog for further details on compressed air quality. Piping Caution 1.

If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to Best Pneumatics No. 5. Lubrication Caution 1. The non-lube type air gripper is lubricated at the factory, and can be used without any further lubrication.

Mandrel Here, : Deformation ration (%) d: Tube diameter (mm) L: Measured length (mm) D: Mandrel diameter (mm) (Twice against the minimum bending radius) Handling of One-touch Fittings Test temperature: 20 5C Relative humidity: 65 5%. Caution 3. Applicable for general industry water. Please consult with SMC if using other fluids.

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent freezing moisture in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

Ambient and fluid temperature range is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent freezing of moisture in circuits below 5C, since this may cause damage to the O-ring and lead to malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

m 2 ) VX32 AC (Full wave rectification) 50/60 10 8.5 60 1 3 5 0.08 1.5 1.0 0.6 220 1.9 VX311 -00 DC 8.5 60 11 60 9.5 50 1 3 5 0.16 0.5 0.3 220 3.8 VX312 -00 50 55 22 60 47 18 AC 0.6 370 VX3225-00 2.2 0.19 4.6 VX33 1.0 530 VX3325-00 AC (Full wave rectification) 50/60 14 11.5 60 1 3 5 0.24 DC 11.5 60 0.3 0.2 5.8 220 1.0 VX313 -00 Note) They are values in an ambient temperatue of 20C 5C

Port R Operating Fluid and Ambient Temperature Operating fluid temperature (C) (3) Vacuum Ambient temperature (C) Temperature conditions Air (Standard) Oil (Standard) (V) Port P Port A Maximum Minimum 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V in parentheses is option symbol. Option Material No.

Water vapors in the circuit to be measured may freeze if the temperature goes below 5C and could damage the O ring or cause the switch to malfunction. The installation of an air dryer is recommended to remove any kind of moisture.

of input/output branches Branch cable Branch cable length Communication connector Power connector 200mA or less Maximum 64 inputs/64 outputs 4 branches (16 inputs/16 outputs per branch) 8 core heavy duty cable 5m or less (total extension 10m or less) M12 connector (8 pins, socket) M12 connector (5 pins, plug) Ambient operating temperature/humidity Enclosure Applicable standard Weight g +5C

Rated voltage 2 Normally open (N.O.) 1 100VAC 3 110VAC [115VAC] Solenoid type Nil Single solenoid Pilot type D Double solenoid Nil Internal pilot R External pilot External pilot cannot be used on a type 41P manifold. 3 5 Plug-in: SS5Y -Type 45 5 SY 5 1 FU Single solenoid: 5 5C FU Double solenoid: 5 SY 5 1 Series Manual override 3 SY300 5 SY500 Nil Non-locking push type D Push-turn locking

VlA Selection Caution Environment Warning VM/VR VH q Use in low temperature environments The valve can be used at a temperature down to 5C. Take appropriate measures to avoid freezing of drainage, moisture, etc. q When the valve is installed in an atmosphere where there is a lot of dust, install a silencer into the port "3(R)".

Normally closed Normally open VNA01 VNA02 VNA03 Valve Double acting Pressure range Lubrication Temperature Style External pilot air 5C to 50C(Air operated: 60C) Note 1) No freezing Note 2) Lubrication is not allowed in case of seal material EPR.

Low temperature operation Avoid ambient temperatures outside the range of 10 to 60C (5C minimum for rubber seals). At low temperatures, appropriate measures should be taken to avoid solidification or freezing of drainage and moisture, etc. 4. Operation for air blowing When using solenoid valves for air blowing, an external pilot type or direct solenoid operated type should be used.

Buffer stroke 25 50 75 100 40 50 63 80 100 125 Series ZPT ZPX Pad Material and Characteristics : Little or no influence : Can be used depending on conditions X: Not suitable Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Solvent resistance (Benzene, toluene) Durometer HS (5C) Base resistance Acid resistance Abrasion resistance Ozone resistance

Moisture in circuits can freeze at 5C or below, causing damage to Orings, and malfunction. Consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits. Furthermore, even though the ambient temperature range remains within specifications, do not operate in locations where there are abrupt temperature changes. 2.