/8 02 R1/4 03 R3/8 04 R1/2 Applicable tubing O.D.
Note 4) Not applicable for dual 3-port valves 2(B) (A)4 1 (P) (R1) 5 3 (R2) C: Locking type (Manual) 3-position closed center 2(B) (A)4 3 B A 1 (P) (R1) 5 3 (R2) 3-position exhaust center r Coil voltage 2(B) (A)4 D: Slide locking type (Manual) 24 VDC 5 4 1 (P) (R1) 5 3 (R2) t Light/surge voltage suppressor 3-position pressure center 2(B) (A)4 Y es Nil 5 1 (P) (R1) 5 3 (R2) 4-position dual
T Connection thread KBB1-M5 KBB2-M6 KBB3-R1 KBB4-R2 Rc1 4 Rc1 8 M6 x 1 M5 x 0.8 Model T Connection thread KBS1-R1 KBS2-R2 KBS3-R3 KBS4-R4 Rc 1 2 Rc 3 8 Rc 1 4 Rc 1 8 15-2-110 3 Combination Examples KBV2-06 Component module 3 Other Pipng Material: KBN, KBD, KBR (P . 15-3-116) KBV2-06 3 KBH2-R2S 1 KBP2 1 KBP2 KB 2 D 1 KB 1 N KBH2-R2S KBV2-M5 Body size Model Model K Body size Component module
Model IDF100F IDF125F IDF150F IDF190D IDF240D Condenser Plate system Shell and coil system Cooling water flow rate [m3/h] *1 50/60 Hz 1.29/1.56 1.74/1.98 2.16/2.52 4.8/4.8 5.4/5.4 Cooling tower performance [RT] *2 2 2.4 3 7.5 7.5 Water flow regulator Pressure type automatic water supply valve Port size for water side R1/2 R3/4 R1 *1 Value with rated load when cooling water inlet temperature
T Connection thread KBB1-M5 KBB2-M6 KBB3-R1 KBB4-R2 Rc1 4 Rc1 8 M6 x 1 M5 x 0.8 Model T Connection thread KBS1-R1 KBS2-R2 KBS3-R3 KBS4-R4 Rc 1 2 Rc 3 8 Rc 1 4 Rc 1 8 15-2-110 3 Combination Examples KBV2-06 Component module 3 Other Pipng Material: KBN, KBD, KBR (P . 15-3-116) KBV2-06 3 KBH2-R2S 1 KBP2 1 KBP2 KB 2 D 1 KB 1 N KBH2-R2S KBV2-M5 Body size Model Model K Body size Component module
push style 4 1 (P) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 (P) VP4 2 2 position double 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 5 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ 3 position double check (A) 4 (B) 2 6Note) VQ4 Light and surge voltage suppressor 1 (P) 5 (R1) 3 (R2) E With W/o light/With surge suppressor VQZ Note) Refer to p.1.11-36 for double check style.
Note Bracket A ZS-46-A1 Tapping screw: Nominal size 3 x 8 L (2 pcs.) Bracket B ZS-46-A2 Tapping screw: Nominal size 3 x 8 L (2 pcs.)
VHS 16.5 1.5 1.5 Max. 6 18.5 3 (Pilot exhaust port) M5 x 0.8 PE R2 P R1 (121.5) Symbol (105) 86.5 (B) 2 (A) 4 13.6 B A 14.7 13.6 12 14 3 (R2) 1 (P) 5 (R1) 35 10.8 17 19.8 35 10.8 0.5 MPa supply 1.6 18 28 25 21 3 13 T.T. O.T. P.T.
Note 4) Not applicable for dual 3-port valves 2(B) (A)4 1 (P) (R1) 5 3 (R2) C: Locking type (Manual) 3-position closed center 2(B) (A)4 3 B A 1 (P) (R1) 5 3 (R2) 3-position exhaust center r Coil voltage 2(B) (A)4 D: Slide locking type (Manual) 24 VDC 5 4 1 (P) (R1) 5 3 (R2) t Light/surge voltage suppressor 3-position pressure center 2(B) (A)4 Y es Nil 5 1 (P) (R1) 5 3 (R2) 4-position dual
Nil F G Rc Example) Attached to the first and third stations ZR1-RV1-1 ZR1-RV1-3 ZR1-R1-A3 T NPTF Example) Attached to the first and third stations ZR1-R1-1 ZR1-R1-3 Example) ZZR106-R .1 pc. (Manifold base only) ZR120S1-K15MZ-EC ... 5 pcs. (Unit) ZR1-BM1 . 1 pc. (Blank plate) ZR1-R1-3 . 1 pc.
Note 2) Not applicable for dual 3 port valve. 3 5 (R1) 3 (R2) 1 (P) 3 position exhaust center (A) 4 (B) 2 4 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 5 5 (R1) 3 (R2) 1 (P) Kit Designation/Electrical Entry/Cable Length S S S F Kit (D-sub connector kit) Kit (Decentralized wiring type serial kit) Kit Kit (Serial output kit) (I/O serial kit) Serial unit: EX250 IP67 compliant
/8, NPT1/8 R1/4*1, NPT1/4*1, G1/4*1, Rc1/8, URJ1/4*2, TSJ1/4*3 Copy function, Auto-shift function Copy function, Auto-shift function *1 M5 female threaded *2 Face seal fitting *3 Compression fitting 3-Screen Display High-Precision Digital Pressure Switch ZSE20B(F)/ISE20B Series 3-Screen Display High-Precision Digital Pressure Switch For General Fluids ZSE20C(F)/ISE20C(H) Series How to Order
Note 3) Value for quick response type Symbol 2 position single 3 position closed center 3 position exhaust center 3 position pressure center 2 position double (Double solenoid) 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) Manifold Specifications Piping specifications Note 4) 1 station weight (g)
Port size P, A, B R1, R2 Piping Model Side Side Bottom Bottom 1 4 3 8 VS7-1-A02 VS7-1-A03 VS7-1-B02 VS7-1-B03 3 8 1 4 3 8 3 8 1.19-8 Series VS7-6 Manifold Manifold: Series VV71 Standard Specifications SV ISO size q Series ISO size q 1 to 10 Manifold block size Applicable solenoid valve Number of stations SY 1 4 3 8 One-touch fitting: 12 1 4 3 8 A, B-port P, R1, R2-port One-touch fitting:
VVZS2000-22A-1 VVZS2000-22A-2 VFN G L M KZ D Cylinder side pressure (P2) Check valve Applicable valve model VZS2450-FZ VZS24504(A) 2(B) 3(R2) 5(R1) 3(R2) 5(R1) 3(R2) 5(R1) 100 Ncm3/ min or less Solenoid one side 1(P) de-energized Leakage (Supply pressure: 0.5 MPa 100 Ncm3/ min or less Solenoid both sides de-energized 1(P) Piston SUP side pressure (P1) SUP side pressure P1 (MPa) 0 Operating
N.O. 1 (P) 5 (R1) 3 (R2) 3 position exhaust center 4 position dual 3 port valve (A) 4 position dual 3 port valve (C) (A) 4 (B) 2 4 2 4 2 5 3 1 5 3 1 1 (P) 5 (R1) 3 (R2) N.C. N.O. N.C.
5 1 4 2 4 2 5 1 A B A B 7 7 R1 P R2 R1 P R2 6 3 position closed center/exhaust center/pressure center 3 position closed center A B 4 2 5 1 PR2 R A 3 position exhaust center A B B PR R 3 position pressure center A B 7 R1 P R2 PR R (This construction shows closed center type.)
VQ1000 Model Response time (ms) (2) Flow characteristics Series Number of solenoids Model Weight Low wattage: 0.5 W Standard: 1 W H: 1.5 W 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) AC (g) C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VQ1160 Metal seal 0.56 12 or less 0.15 0.13 0.60 0.12 0.14 15 or less 29 or less Single 2 position 3 position VQ1161 Rubber seal 0.71 15 or less 0.20 0.17 0.80 0.16
3 !2 @0 @1 !7 !5 !0 t @3 Component Parts No.
(P) (B) 2 (A) 4 3 position exhaust center (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 i 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 (R2) 1 (P) (This figure shows a closed center type.)