-6 = 9.0 x 10-6 (kgm2) Moment of inertia around Z axis IA = IZ1 + m1r12 X 10-6 z r2 Z2 B part r2 = 47(mm) Calculation of weight m2 = d x e x f x Specific gravity m2 = 5 x 10 x 12 x 2.7 x 10-6 = 0.002 (kg) Moment of inertia around Z2 axis IZ2 = {m2 (d2 + e2)/12} x 10-6 IZ2 = {0.002 x (52 + 102)/12} x 10-6 = 0.02 x 10-6 (kgm2) IB = 0.02 x 10-6 + 0.002 x 472 x 10-6 = 4.4 x 10-6 (kgm2) I =

-6 = 9.0 x 10-6 (kgm2) Moment of inertia around Z axis IA = IZ1 + m1r12 X 10-6 z r2 Z2 B part r2 = 47(mm) Calculation of weight m2 = d x e x f x Specific gravity m2 = 5 x 10 x 12 x 2.7 x 10-6 = 0.002 (kg) Moment of inertia around Z2 axis IZ2 = {m2 (d2 + e2)/12} x 10-6 IZ2 = {0.002 x (52 + 102)/12} x 10-6 = 0.02 x 10-6 (kgm2) IB = 0.02 x 10-6 + 0.002 x 472 x 10-6 = 4.4 x 10-6 (kgm2) I =

VVZS2000-22A-1 VVZS2000-22A-2 VFN G L M KZ D Cylinder side pressure (P2) Check valve Applicable valve model VZS2450-FZ VZS24504(A) 2(B) 3(R2) 5(R1) 3(R2) 5(R1) 3(R2) 5(R1) 100 Ncm3/ min or less Solenoid one side 1(P) de-energized Leakage (Supply pressure: 0.5 MPa 100 Ncm3/ min or less Solenoid both sides de-energized 1(P) Piston SUP side pressure (P1) SUP side pressure P1 (MPa) 0 Operating

Plug-in type Non plug-in type VVZS3000-22A-1 VVZS3000-22A-2 VFN G L M KZ D Cylinder side pressure Check valve Applicable valve model VZS3450-FZ VZS34504(A) 2(B) 3(R2) 5(R1) 3(R2) 5(R1) 3(R2) 5(R1) 210 Ncm3/ min or less Solenoid one side energized 1(P) 210 Ncm3/ min or less Leakage 0.5 MPa Solenoid both sides energized 1(P) Piston SUP side pressure P1 SUP side pressure P1 (MPa) 0 Operating

Switch (When equipped with switch) Internal Pilot Manifold L Dimension n: Stations External Pilot Manifold L Dimension n: Stations L n 4 173 162.5 145 14 L n 4 185.5 175 155.5 15 2 148 137.5 124 12 3 160.5 150 134.5 13 5 185.5 175 155.5 15 6 198 187.5 166 16 7 210.5 200 176.5 17 8 210.5 200 187 12 9 223 212.5 197.5 13 2 160.5 150 134.5 13 3 173 162.5 145 14 5 198 187.5 166 16 6 210.5 200

300 40 30 20 10 0 30 25 20 15 10 5 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 100 100 50 40 30 20 10 0 100 80 60 40 20 0 Load (N) Load (N) 336 MSQX Series Low-Speed Rotary Table Rack & Pinion Type Construction CRB2 CRB1 MSU CRJ CRA1 o i @5 @6 t y !

Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.

Example) L6: Elbow with One-touch fittings for 6 Note 2) See Options for One-touch fittings in inch sizes. 100V AC (50/60Hz) 2 position single (1) 200V AC (50/60Hz) SY 1 110V AC (50/60Hz) (1) 220V AC (50/60Hz) 24V DC SYJ 2 position double (latching) 12V DC Note 1) 200/220V AC models are applicabe to the C kit.

EVS (Pitch) Manual override (Non-locking) VFN M5 x 0.8 (PE port) 4-4.5 Mounting hole 2-Rc 1/8 (1(P) port) (4(A), 2(B) port) 300 (Lead wire length) (Pitch) (5(R1), 3(R2) port) (mm) Stations 2 3 50 40 66 56 20 338 328 L1 L2 4 82 72 5 98 88 6 114 104 7 130 120 8 146 136 9 162 152 10 178 168 11 194 184 12 210 200 13 226 216 14 242 232 15 258 248 16 274 264 17 290 280 18 306 296 19 322 312 3-3

Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).

XMA series with KF (NW) flange A (mm) Model Weight (kg) Conductance (L/s) B (mm) CYV XMA-16 40 103 0.33 5 XMA-25 XMA-40 XMA-50 50 113 0.61 14 B 65 158 1.40 45 70 170 2.00 80 A 160 XMA-63 XMA-80 88 196 3.60 90 235 6.20 200 A : Common to all series. 479 Series Variations Operating pressure Flange size Shaft seal system Models Valve type Angle type In-line type Options Application Switch Indicator

VV72-P-03, 04 R1, R2 individual EXH spacer VV72-R2-04 Reverse pressure spacer AXT512-19ASilencer box AXT512-26A 1 2 SMC SMC 223.5 211.5 183.5 171.5 140 PA B 80.5 120.5 PE PE PE PA P PE PE P 78 R2 R1 R1 R2 EA EB EB EA A Individual EXH spacer: VV72-R2-Rc3/8, 1/2 Individual SUP spacer: VV72-P2-Rc3/8, 1/2 R1, R2 individual EXH spacer: VV72-R2-04 2-Rc1/2 Reverse pressure spacer: AXT512-19A2-Rc3

R2 JIS Symbol 5/2 monostable Solenoid Valv with elastomer coated spool Fi$.7.23 P N E U M A T I C T E C H I I O L O G Y , The 5/3 valve has a third (center) position to which it will retum, by means of springs, when bolh solenoids rare de-energized.

R2 JIS Symbol 5/2 monostable Solenoid Valv with elastomer coated spool Fi$.7.23 P N E U M A T I C T E C H I I O L O G Y , The 5/3 valve has a third (center) position to which it will retum, by means of springs, when bolh solenoids rare de-energized.

LQ3U31-R1 LQ3U31-R2 LQ3U32-R1 LQ3U32-R2 LQ3U41-R1 LQ3U41-R2 LQ3U51-R1 LQ3U51-R2 LQ3U61-R1 LQ3U61-R2 LQ3U2A-R1 LQ3U3A-R1 LQ3U3A-R2 LQ3U4A-R1 LQ3U4A-R2 LQ3U5A-R1 LQ3U5A-R2 LQ3U5A-R3 LQ3U6A-R1 LQ3U6A-R2 LQ3U7A-R1 4 x 3 1/4" x 5/32" 3 x 2 4 x 3 3 x 2 8 x 6 6 x 4 6 x 4 4 x 3 10 x 8 8 x 6 12 x 10 10 x 8 19 x 16 12 x 10 1/8" x 0.086" 1/4" x 5/32" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/

R1 R2 P 11.5 12 18 22 22 27.2 (R1, R2 port) 2-Rc(PT)1/4 63 5-Rc(PT)1/8 (Piping port) 3.1-21

) Air N2 1 L/min 10 100 2 L/min 20 200 5 L/min 50 500 PF3A7 H Thermal type (Platinum sensor) 2 L/min 30 3000 p. 9 Air N2 PFG300 5 L/min 60 6000 p. 14 12000 Bypass flow type 10 L/min 120 0.2 PFM 0.01 L/min 10 Dry air N2 Ar CO2 0.5 25 Thermal type (MEMS) 0.1 L/min 1 50 2 100 PFMB 2 200 Thermal type (MEMS) 5 500 Dry air N2 1 L/min Bypass flow type 10 1000 PFG300 20 2000 PFMC 5 500 Thermal

push style 4 1 (P) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 (P) VP4 2 2 position double 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 5 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ 3 position double check (A) 4 (B) 2 6Note) VQ4 Light and surge voltage suppressor 1 (P) 5 (R1) 3 (R2) E With W/o light/With surge suppressor VQZ Note) Refer to p.1.11-36 for double check style.

M3 x 10 (4 pcs.) 11 14 15 20 740 AHC System Series MA2 How to Order AHC unit AHC unit MA 210 Y M3 N R3 Tool adapter Robot adapter Without robot adapter 8 10 11 14 15 20 Nil S1 R1 R2 R3 R4 R5 Auto hand changer Air gripper for AHC Applicable shaft diameter Transportable mass Transportable mass 3 kg 2 AHC unit Electric specifications Air connection size M3 M3 x 0.5 None N Air gripper for AHC

0.5 0.5 0.5 60 15 0.4 0.3 0.4 150 0.4 40 0.3 10 0.3 100 0.2 0.2 0.2 5 20 50 0 0 40 Gripping point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHW2-25D MHW2-40D 160 50 Pressure 0.7 MPa Pressure 0.7 MPa MHZ 140 0.6 0.6 40 120 Gripping force (N) Gripping force (N) 0.5 0.5 MHF 100 30 0.4 0.4 80 0.3 MHL 0.3 0.2 20 60 0.2 40 MHR 10 20 MHK