pressure 100 psi (0.7MPa) High pressure type 113 psi (0.8MPa) Min. operating pressure 14 psi (0.1MPa) 21 psi (0.15MPa) Valve specifications Solenoid specifications Note 1) Note 1) Ambient and fluid temperature 14 to 122F 14 to 122F Max. operating frequency 20Hz 5Hz Proof pressure 217 psi (1.5MPa) Lubrication Not required Manual override Non-locking push type/Slotted locking type 150/30 m/s2
No Initial value Recommended value Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 65536 114688 32768 65536 Electronic gear denominator *3 PA07 1 250 125 125 125 250 125 125 Regenerative option PA02 0 0 (Non)/ 0002 (LEC-MR-RB-032)/ 0003 (LEC-MR-RB-12) 1 Rotation direction selection *4 PA14 0 0 (+Counter motors side ) (+Counter motors side
250 262.5 (L4) 135.5 135.5 148 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273 Stations are counted from the D side Courtesy of Steven Engineering, Inc. !
350 200 300 40 30 20 10 0 30 25 20 15 10 5 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 100 100 50 40 30 20 10 0 100 80 60 40 20 0 Load (N) Load (N) 336 MSQX Series Low-Speed Rotary Table Rack & Pinion Type Construction CRB2 CRB1 MSU CRJ CRA1 o i @5 @6 t y !
ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250
(at 0.5 MPa) 3 position 30 or less 2 position single, double 10 Max. operating frequency (Hz) 3 position 3 Body ported Manual override (Manual operation) Pilot exhaust method Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type Main/Pilot valve common exhaust Lubrication Mounting orientation Not required Unrestricted Note 2) Impact/Vibration resistance (m/s2
588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Manual override (Manual operation) Pilot exhaust method Non-locking push type, push-turn locking slotted type, push-turn locking lever type Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Lubrication Mounting orientation Not required Unrestricted Note 2) Shock/Vibration resistance (m/s2
Lubrication Not required Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.
These default values can be changed in the Offset FB Overall Accuracy +/5% (0.5V DC) Input Impedance 150 kOhm or higher Input Voltage 0 10V DC Conversion Speed 10 ms Resolution 10/250 mv Analog Input Range 0 250 ECC-PNAL-20M*-D 8 Channels: I01 I08 ECC-PNAL-10M*-D 6 Channels: I01 I06 Description Analog Input Specication 7 2.4 Output Specication PneuAlpha Hardware Specification 2 Table 2.7
(MPa) 1 (P) 1 (P) 5 (R1) 3 (R2) 3 (R) Ambient and fluid temperature C 2 position double 2 position double 2 position single,double 3 position 2 position single,double 3 posittion (4) (B) 2 (A) 4 Response time (ms) at 0.5MPa (A) 4 (B) 2 Max. operating frequency (Hz) 1 (P) 5 (R1) 3 (R2) 1 (P) 3 (R) Manual override Pilot exhaust Lubrication Mounting position Impact/Vibration resistance (m/s2
Do not drop, bump, or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 5. Do not allow short circuiting of loads.
135 209 460 613 175 250 2 1 1 1 4 1 2 , , ALDU600-06 to 10, ALDU900-12 to 20 D.P.
Note 4) (ft/s2) 30/150 (9/150ft/s2) Rated voltage 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz) Allowable voltage fluctuation % 10% of rated voltage Coil insulation type Class B Enclosure Note 5) Dust proof (equivalent to IP40) Power consumption W Note 3) 2.5 (VDW10), 3 (VDW20/30) Note 1) Consult P/A when used under conditions which may cause condensation on the exterior of the
The station address is set using the rotary switches S1 and S2. (1) Settings of the Rotary Switches S1 and S2 Set the station address using the rotary switches S1 and S2.
VAC for 1 min, between all lead wires and enclosure 2 M or more (at 50 VDC) between all lead wires and enclosure 10 to 500 Hz with 1.5 mm amplitude or 98 m/s2, whichever is smaller 980 m/s2 in X, Y, Z directions 3 times each (Not energized) 3% F .S. or less of measured pressure at 25C in temperature range of 0 to 50C Pressure receiving area: Stainless steel 630, Fittings: Stainless steel
Note 4) (ft/s2) 30/150 (9/150ft/s2) Rated voltage 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz) Allowable voltage fluctuation % 10% of rated voltage Coil insulation type Class B Enclosure Note 5) Dust proof (equivalent to IP40) Power consumption W Note 3) 2.5 (VDW10), 3 (VDW20/30) Note 1) Consult SMC when used under conditions which may cause condensation on the exterior of the
Do not drop, bump, or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 5. Do not allow short circuiting of loads.
Control equipment connected to the barrier must not use or generate more than 250 V. 2. Installation should be in accordance with Canadian Electrical Code or ANSI/ISA RP12.6 Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations and the National Electrical Code or ANSI/NFPA 70. 3.
Mounting orientation is Upper direction Model Port size Rc(PT) 63 63 80 85 90 100 B C A INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 1/4 141 164.5 170 180 230 251 15 15 15 20 22 22 3/8 1/4, 1/2 3/8, 3/4 3/4, Bracket dimensions Model Port size B C D E A 1 F 345 419.2 K 57 49.6 J 14 14 H 95 120 G 32.5 0 1 1 1 1 2 4, 1 2, 1 175 250 175 250 87.5 125 460 613 135 209 4, 3 ALD600
Prefix it to the part nos. of the solenoid valve, etc. 5-4-3 Series SYJA300 Specifications Compact and lightweight Fluid Operating pressure range (MPa) Pilot pressure range MPa Note 1) Air 0.15 to 0.7 Operating pressure range to 0.7 Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note 2) 10 to 50 (No freezing. Refer to page 5-11-4.)