Body Class: Orifice Diameter ø4, Valve Type: Normally Closed, Applicable Tube OD: ø6, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: Flow Rate Adjustment, Specification: -, Z: -
Body Class: Orifice Diameter ø4, Valve Type: Normally Closed, Applicable Tube OD: ø6, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: None, Specification: Vacuum, Z: -
Body Class: Orifice Diameter ø8, Valve Type: Normally Closed, Applicable Tube OD: ø6, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: By-pass, Specification: -, Z: -
Body Class: Orifice Diameter ø8, Valve Type: Normally Closed, Applicable Tube OD: ø6, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: Flow Rate Adjustment & By-pass, Specification: -, Z: -
Body Class: Orifice Diameter ø8, Valve Type: Double Acting, Applicable Tube OD: ø6, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body: PFA, Actuator Endplate: PPS, Diaphragm: PTFE, Option: Flow Rate Adjustment, Specification: -, Z: -
Body Class: Orifice Dia. ø4, Valve Type: N.C., Applicable Tubing Size: ø6mm, Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: With Flow Rate Adjustment
Body Class: Orifice Dia. ø8, Valve Type: N.C., Applicable Tubing Size: ø6mm, Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: With By-Pass
Compatible Fluid: Chemical, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: Tube Connection, Tube Diameter: φ6, Operating Temperature Range(°C): 0~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): 0.3~0.5, Orifice Diameter(Ø): 4, Option: None
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLUOROPOLYMER, VALVE, VALVE, FLUOROPOLYMER, 6.17294 lb
High purity chemical valves, series LVC with integral fittings eliminate the possibility of residual liquid in pipe threads. In addition, the body has been designed for smooth flow with minimal internal dead space. Special diaphragm construction insures gentle opening and closing preventing the formation of micro-bubbles. A unique guide ring on the piston rod eliminates lateral motion of
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLUOROPOLYMER, VALVE, VALVE, FLUOROPOLYMER, .62919 lb
Body Class: 2 (Orifice Diameter ø4), Valve Type: 0 (Normally Closed), Applicable Tube OD: 06 (ø6), Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: 1 (Flow Rate Adjustment), Specification: V (Vacuum)
Body Class: 2 (Orifice Diameter ø4), Valve Type: 0 (Normally Closed), Applicable Tube OD: 06 (ø6), Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: 1 (Flow Rate Adjustment), Specification: None, Z: Z (Pilot Port Thread 1/8)
Body Class: 2 (Orifice Diameter ø4), Valve Type: 0 (Normally Closed), Applicable Tube OD: 06 (ø6), Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: None, Specification: V (Vacuum), Z: Z (Pilot Port Thread 1/8)
High purity chemical valves, series LVC with integral fittings eliminate the possibility of residual liquid in pipe threads. In addition, the body has been designed for smooth flow with minimal internal dead space. Special diaphragm construction insures gentle opening and closing preventing the formation of micro-bubbles. A unique guide ring on the piston rod eliminates lateral motion of
High purity chemical valves, series LVC with integral fittings eliminate the possibility of residual liquid in pipe threads. In addition, the body has been designed for smooth flow with minimal internal dead space. Special diaphragm construction insures gentle opening and closing preventing the formation of micro-bubbles. A unique guide ring on the piston rod eliminates lateral motion of
High purity chemical valves, series LVC with integral fittings eliminate the possibility of residual liquid in pipe threads. In addition, the body has been designed for smooth flow with minimal internal dead space. Special diaphragm construction insures gentle opening and closing preventing the formation of micro-bubbles. A unique guide ring on the piston rod eliminates lateral motion of
Body Class: Orifice Diameter ø4, Valve Type: Normally Closed, Applicable Tube OD: ø6, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: Flow Rate Adjustment, Specification: Vacuum, Z: -
Body Class: Orifice Diameter ø4, Valve Type: Normally Closed, Applicable Tube OD: ø6, Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: None, Specification: Vacuum, Z: Pilot Port Thread 1/8
Compatible Fluid: Chemical, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: Tube Connection, Tube Diameter: φ6, Operating Temperature Range(°C): 0~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): 0.3~0.5, Orifice Diameter(Ø): 4, Option: With