Ionized air from IZN10E ionizer neutralizes static electricity and blows dust away from the workpiece. 1.2 Installation and Piping 1. This product must be installed on a stable horizontal surface. 2. Avoid using in a place where noise (electromagnetic wave and surge) is generated. It may cause failure or damage to the product.
Ionized air from IZN10E ionizer neutralizes static electricity and blows dust away from the workpiece. 1.2 Installation and Piping 1. This product must be installed on a stable horizontal surface. 2. Avoid using in a place where noise (electromagnetic wave and surge) is generated. It may cause failure or damage to the product.
POWER SUPPLY CABLE, IZN10E, IONIZER, NOZZLE TYPE, 873, 502 lb
POWER SUPPLY CABLE, IZN10E, IONIZER, NOZZLE TYPE, 873, 27 lb
The ION/HV LED on a new IZN10E series main unit should be ON (green) when the unit is discharging normally.
However, if the HV or ION/HV LED is ON (red), this indicates a high-voltage error has occurred.
The main cause of this is usually foreign matter or water droplets adhering to the emitter (electrode needle).
Remove the cartridge and clean the emitter.
Note) Old IZN10 and new IZN10E series body assemblies are not interchangeable.
The IZN10E is SMC's nozzle ionizer. The nozzle ionizer emits an air-assisted cone of static eliminating ions for focused targets 2 inches or smaller, up to 20 inches away. The nozzle can be used with an optional sensor and monitor to suspend emission when static elimination is complete, or when the target is not present.
The IZN10E is SMC's nozzle ionizer. The nozzle ionizer emits an air-assisted cone of static eliminating ions for focused targets 2 inches or smaller, up to 20 inches away. The nozzle can be used with an optional sensor and monitor to suspend emission when static elimination is complete, or when the target is not present.
s) L1 : Distance to the center of load gravity (m) ME : Dynamic moment (Nm) g : Gravitational acceleration (9.8 m/s2) At impact: = 1.4 a 1.4 100 = 1.4 a (mm/s) FE = agW Note 4) ME = FEL1 = 0.05 agWL1 (Nm) 1 3 Note 4) Average load coefficient (This coefficient is meant to average the maximum load moment at the time of impact with stopper in the light of calculating the service life.) 1106
Do not use it in a line that is kept pressurized because it could cause the body to break. 1106 Air Suction Filter Series ZFA Dimensions: ZFA 100 200 Single unit Bracket ZA ZX ZR Cover opened-up dimensions 70 Element extracted dimensions 55 ZM ZMA ZQ 2 x 4.5 ZH ZU 2 x Port size ZL Note) The above diagram is for ZFA200. The bracket location shows L side.
Air slide table, Bore size: 6, 8, 12, 16, 20, 25 *, Strokes: 5mm to 150mm, depending upon bore size, With or without stroke adjuster with or without shock, Options: buffer, end lock, axial piping, Variety of switches with a variety of wire lead lengths, Cyl, Air Slide Table, GUIDED CYLINDER, 1106 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, with Auto Switch, GUIDED CYLINDER, 1106 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, with Auto Switch, GUIDED CYLINDER, 1106 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, with Auto Switch, GUIDED CYLINDER, D83, 1106 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, with Auto Switch, GUIDED CYLINDER, D83, 1106 lb
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100, Standard stroke range *: 5 to 100, Port threads: M *; Rc, NPT or G *, Auto switch capable, Compact Cylinder, CQ2-Z, COMPACT CYLINDER, 493, 1106
Unique air cushion construction with no cushion ring, Wide size variations from °20 to °100, Nearly three times the allowable kinetic energy, Improved noise reduction * and repeatability, Interchangeable mounting, Cyl, Compact, Air Cushion, Sw Capable, COMPACT CYLINDER, 1106 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cyl, Slide Table, GUIDED CYLINDER, D79, 1106 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, with Auto Switch, GUIDED CYLINDER, 1106 lb
Common exhaust for main valve and pilot valve is also available.VF5000 series manifold, Metric threads (Rc(PT)), Manifold type: B mount (single base), Maximum stations: 15, Port sizes: 1/4, 3/8, 1/2, Common/SUP, Common/EXH, Manifold Base, 4/5 PORT SOLENOID VALVE, 1106 lb