Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: P (PNP Output), Power Supply Cable, AC Adapter: H (e-con Connector, Power Supply Cable to be Provided & Prepared by Customer), Bracket: B (Bracket)
Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: P (PNP Output), Power Supply Cable, AC Adapter: Power Supply Cable, 3m, Bracket: B (Bracket)
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): -, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): null~0.7, Power Supply: DC24V, Accessories/options: ordered separately: Power supply cable included (3 m) / with bracket, I/O specifications: PNP output, Bar length
Type: Fan Type, Indicator: Error, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): 0.66, Ion Balance: -, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Accessories/options: ordered separately: e-con connector / With bracket, I/O specifications: PNP output, Bar length(mm): -, Emitter cartridge type: -,
Type: Fan Type, Indicator: Error, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): 0.66, Ion Balance: -, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Accessories/options: ordered separately: None, I/O specifications: PNP output, Bar length(mm): -, Emitter cartridge type: -, Emitter material: -, Sensor
Type: Fan Type, Indicator: Error, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): 0.66, Ion Balance: -, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Accessories/options: ordered separately: With bracket, I/O specifications: PNP output, Bar length(mm): -, Emitter cartridge type: -, Emitter material:
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): -, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): null~0.7, Power Supply: DC24V, Accessories/options: ordered separately: Power supply cable included (10 m) / with bracket, I/O specifications: NPN output, Bar length
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): -, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): null~0.7, Power Supply: DC24V, Accessories/options: ordered separately: Without power supply cable / with bracket, I/O specifications: PNP output, Bar length(mm): 620
Type: Fan Type, Indicator: Error, Additional Function: Error Signal Output, Air Flow/Consumption Amount(m3/min): 0.66, Ion Balance: -, Ion Balance Adjusting Function: Manual, Operating Pressure Range(MPa): -, Power Supply: DC24V, Accessories/options: ordered separately: With AC adapter (without AC cord) / With bracket, I/O specifications: PNP output, Bar length(mm): -, Emitter
Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: PNP Output, Power Supply Cable, AC Adapter: Power Supply Cable , 10m, Bracket: -
Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: PNP Output, Power Supply Cable, AC Adapter: AC Adapter + Connector, Bracket: -
E GB F GA PIN WC CUSHION NEEDLE (HEX 1.5) LB N NN W WA WB WC Y YC ZB ZC ZD 3.74 0.75 5/8-18 0.50 0.60 0.86 90 0.95 0.63 4.02 0.09 1/8 NPT 3.82 0.88 5/8-18 0.62 0.72 0.82 90 1.17 0.63 4.10 0.09 1/8 NPT 4.37 1.25 3/4-16 0.88 0.85 0.98 45 1.50 0.78 4.75 0.09 1/8 NPT 5.62 1.75 1 1/4-12 1.19 1.20 1.45 45 1.91 1.03 6.06 0.12 1/4 NPT 4 Stainless Steel Body Cylinder Series NCM-A Dimensions ZB + STROKE
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, ZB EJECTOR MANIFOLD, ZB, VACUUM EJECTOR, 0.00000 lb
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, ZB EJECTOR MANIFOLD, VACUUM EJECTOR
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, ZB EJECTOR MANIFOLD, VACUUM SERIES, OTHER OTHER MISC., 2X, OTHER NO SIZE RATING, 0.03747 lb
The ZB is available as a single unit or mounted to a manifold of up to 12 stations.?Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch?
The ZB is available as a single unit or mounted to a manifold of up to 12 stations.?Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch?, ZB EJECTOR MANIFOLD, VACUUM SERIES, OTHER OTHER MISC., 2X, OTHER NO SIZE RATING, 0.476 lb
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, ZB EJECTOR MANIFOLD, VACUUM EJECTOR