This is a legacy product, and replaced byISE78G-02-L2-M, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .56564 lb
-X465 0.1 to 1 Set pressure range (MPa) Desolution of setting and display (MPa) Power supply voltage Specifications AU 0.001 Class 10 With M5 fitting (Applicable tubing O.D. 6) Pressure switch Cleanliness Breather port 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection) 45 mA or less (but 70 mA or less at current output) AF IR1000/2000: With M5 fitting (Applicable
fitting 8 (5/16") one-touch fitting 1/4" one-touch fitting Output specification A B C D E F G H 2 NPN outputs 2 PNP outputs 1 NPN output + Analog (1 to 5 V) 1 NPN output + Analog (4 to 20 mA) 1 PNP output + Analog (1 to 5 V) 1 PNP output + Analog (4 to 20 mA) 1 NPN output + External input Note 3) Piping entry direction Straight Bottom Nil L Different combinations of piping entry directions
Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: Fixed SI Unit, MPa, Option 1: None, Option 2: With Bracket
Piping: G1/4, ISO1179, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: Fixed SI Unit, MPa, Option 1: None, Option 2: With Bracket
Piping: G1/4, ISO1179, Output: 27 [NPN Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: Fixed SI Unit, MPa, Option 1: None, Option 2: With Bracket
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type])
DIN rail is not suitable for port size F02 (G1/4). No lead wire 1
Note 4) At the atmospheric pressure, 1 VDC or 4 mA is output. 5 VDC or 20 mA is output at the rated pressure. Note 5) Please contact SMC regarding indication with other units of pressure. 0 25 50 75 100 Input signal (% F.S.)
to 40 mA 4 V or less 0.8 mA or less 1 ms or less Operating positionRed light is ON.
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: None, Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)