SCS1/SSL1: 16 points SCS2/SSL2: 8 points 16 points 16 points Number of outputs Connection load SMC: Solenoid valve with light/surge voltage suppressor (24 VDC, 2.1 W or less) Output when communication error occurs Hold/Clear (Switch setting) Clear Enclosure IP20 0 to +55C (Valve 8 points ON) 0 to +50C (Valve 16 points ON) Operating temperature range Operating humidity range 35 to 85%RH (With
MPa Exhaust ow rate 410 to 1580 L/min (ANR) 820 to 3160 L/min (ANR) Dust collector Fluid Air (Dry air) Operating pressure range 0.2 to 0.8 MPa Power supply voltage 85 to 264 VAC 50/60 Hz (when using the exclusive AC adaptor) Operating time setting Continuous/Timer [2/5/10 s] Additional air blow setting Continuous blow/Pulse blow [50/100 ms intervals] Body Operating temperature range 0 to 55C
This is a legacy product, and replaced byCP96SDB50-55C, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, NE, 50MM C95/CP95 DBL-ACT AUTO-SW, 6.50916 lb
Rated current [A]Control power supply voltage [V]LECSS2-S8400Absolute 18-bit encoder (Resolution: 262144 pulse/rev)Three phase 200 to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)Three phase 170 to 253 VACSingle phase 170 to 253 VAC2.6Single phase 200 to 230 VAC (50/60 Hz)Single phase 170 to 253 VAC0.2SSCNET III (High-speed optical communication)USB communication32 to 131F (0 to 55C
FG 14 Photomicrosensor Series LG1H Photomicrosensor for Home Position Ratings Power supply voltage 5 to 24VAC 10%, ripple (p-p)10% or less Current consumption 35mA or less 5 to 24VAC, Load current (1c)100mA, Residual voltage 0.8Vor less Control output Load current (1c) 40mA, Residual voltage 0.4V or less Ambient operating temperature Operation: -25 to 55C (Storage: -30 to 80C) Operation:
Clamping tool PCW-994518 7 Series PCW Branch Unit: PLC Direct Connected Type Specifications PLC connection Weight 25 g Ambient temperature 25 to 55C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 7.
94 Series LTF/Switches Photo Micro Sensor Standard Photo Micro Sensor for Home Position (OMRON Corporation) Rating Power supply voltage 5 to 24 VDC 10%, Ripple (p-p) 10% or less Current consumption 35 mA or less 5 to 24 VDC load current (Ic) 100 mA, Residual voltage 0.8 V or less Control output Load current (Ic) 40 mA, Residual voltage 0.4 V or less Ambient temperature Operation: 25 to 55C
AL01 Low level in tank Changeable alarm set values HRS 100/150 Setting item Set value Flashing PV 5 to 55C 1 to 34C 0.05 to 0.6 MPa 0.05 to 0.6 MPa Circulating fluid discharge temperature rise Circulating fluid discharge temperature drop Circulating fluid discharge pressure rise Circulating fluid discharge pressure drop HRSH 090 Alarm code Lights up HRSH HRSE HRZ HRZD Alarm codes notify of
AL01 Low level in tank Changeable alarm set values Setting item Set value Flashing PV 5 to 55C 1 to 39C 0.05 to 0.6 MPa 0.05 to 0.6 MPa Circulating fluid discharge temperature rise Circulating fluid discharge temperature drop Circulating fluid discharge pressure rise Circulating fluid discharge pressure drop Alarm code Lights up Alarm codes notify of checking times.
Series IDU High inlet air temperature type Rated inlet air temperature: 131F (55C) [Max. inlet air temperature: 176F (80C)] Refer to SMC website for details.
Ambient temperature: 32C Water cooled aftercooler Inlet air temperature: 180C Inlet temperature of cooling water: 30C Note 2) Series IDF Inlet air temperature: Saturated at 35C (IDF1D), saturated at 40C (IDF2D to 240D), Ambient temperature: 32C Note 3) Series IDG Inlet air temperature: Saturated at 25C, Ambient temperature: 25C Note 4) Series IDU Inlet air temperature: 60C (IDU3D to 6D), 55C
Accessory (Option) Tank capacity ID D With auto-drain F Companion flange Port size Capacity ( l ) 100 200 400 500 700 1000 1500 Applicable compressor (kW) 5.5 Symbol AMG 6C 04 Rc 06 14 20 30 1 2 Rc 3 4 Rc 1 1 2 2B flange 3B flange 40 4B flange AT6C AT11C AT22C/37C AT55C/75C AT125C AT150C/220C 11C 11 22C 22 AFF 37C 37 55C 55 AM 75C 75 125C 125 2000 150C 150 3000 220C 220 Misc. 14-16-1 2 Series
Inlet air temperature 35C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.5MPa Air flow 1200 l/min (ANR) Inlet air temperature 55C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.7MPa Air flow 350 l/min (ANR) Condition Condition A = 0.75 based on conditions q, w and e 1 1 B = 0.95 based on conditions q, w and e C = 1.00 based on
Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CB, ISE2 1/8INCH NPT VERSION, .22027 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics(Based on 25C)Withstand voltageInsulation resistancePort
Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CA, ISE2 1/8INCH PT VERSION, .42518 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics(Based on 25C)Withstand voltageInsulation resistancePort
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CA, ISE2 1/8INCH PT VERSION, .11364 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CA, ISE2 1/8INCH PT VERSION, .19153 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CA, ISE2 1/8INCH PT VERSION, .23988 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CA, ISE2 1/8INCH PT VERSION, .23075 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE2 PRESSURE SWITCH, CA, ISE2 1/8INCH PT VERSION, .13457 lb, ModelRated pressure range/Set pressure rangeProof pressureFluidPower supply voltageCurrent consumptionResponse timeRepeatabilityResistanceTemperature characteristics