Auto Switch Mounting Height (mm) D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G5BA D-G59F Auto switch model D-F5 D-J59 D-F5W D-J59W D-F5BA D-F59F D-F5NT D-Z7 D-Z80 D-Y59 D-Y7P D-Y7BA D-Y7W D-A9 D-M9 D-M9W D-M9A D-A3C D-G39C D-K39C D-A44C D-A9V D-M9V D-M9WV D-M9AV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-Y69 D-Y7PV D-Y7WV Bore size (mm) Ht Hs 40 50 63 80 100 Hw Hs Ht Hs Ht Hs Ht Hs
(incl. band & screws) 25 32 40 Bore size (mm) 20 Auto switch models Bore size (mm) Axial foot CHN-L032 CHN-L040 CHN-L020 CHN-L025 D-C7, D-C8 D-H7 D-B5, D-B6 D-G5, D-K5 D-A3, D-A4 Flange CHN-F032 CHN-F040 CHN-F020 CHN-F025 When ordering the axial foot type, order 2 pieces for each cylinder. 20 BMA2-020 BA-01 BD1-01M 25 BHN3-025 BHN2-025 BD1-02M 32 BHN3-032 BGS1-032 BHN1-032 40 BHN3-040 BH2
Example) AR30-03BG-NR-B-X425 Symbol Description Nq Body size 25 30 40 50 60 Symbol Description Nq Body size 20 25 30 40 50 60 Nw Pipe thread type Nil Rc N NPT F G + Nw Pipe thread type Nil Rc N NPT F G + 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without mounting option B*2 With bracket a Mounting Option *1 H With set nut (for
6 8 11.5 6.5 32 18.5 13 16 11.5 15 18.5 14.5 13.5 19.5 13.5 8 10 13.5 8.5 40 23 17.5 17 21 19.5 23 24 20 18 19 13.5 15.5 19 14 Auto switch mounting heights (mm) D-C7 D-C8 D-H7 D-H7W D-H7F D-H7BAL D-G39 D-K39 D-A33 D-A34 D-A44 D-B5/B6 D-B59W D-G5NTL D-H7C D-C73C D-C80C Bore size (mm) HS HS HS HS HS 24.5 27.5 27 62 72 20 27 30 29.5 64.5 74.5 25 30.5 33.5 33 68 78 32 40 35 38 37.5 72.5 82.5
Standard Stroke Bore size (mm) Standard stroke (mm) Range of manufacturable stroke Auto switch model 40 CV Bore size (mm) 50 63 80 100 Without rod boot With rod boot Without rod boot With rod boot D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL 40 25 to 850 25 to 700 Up to 1200 Up to 950 MVGQ 50 25 to 800 25
Applicable bore size (mm) 32, 40 UA C d1 d2 H k L UT Weight (g) 25 YU-03 17 11 15.8 14 M8 x 1.25 8 7 6 YU-05 50, 63 17 13 19.8 18 M10 x 1.5 10 7 6 40 9-12-20 21 Proper Auto Switch Mounting Position (Detection at stroke end) and lts Mounting Height D-A9V D-M9V D-F9WV D-A9 D-M9 D-F9W D-F9BAL B Approx. Hs Approx.
Applicable bore size (mm) 32, 40 17 11 15.8 14 M8 x 1.25 8 7 6 YU-03 50, 63 17 13 19.8 18 M10 x 1.5 10 7 6 40 YU-05 15 Compact Cylinder with Air Cushion and Lock Series RLQ Auto Switches/Proper Mounting Positions and Height for Stroke End Detection D-A9 D-F9 D-F9W D-A9V D-F9V D-F9WV D-F9BAL B Approx. Hs Approx.
Action D Double acting Cylinder stroke Bore size (mm) Standard stroke (mm) Mounting Bore size 10, 20, 30, 40 10 Through hole & double end tapped (standard) Foot type Front flange type Rear flange type Double clevis type B L F G D Note) 10 16 20 25 28 10mm 16mm 20mm 25mm 28mm 10, 20, 30, 40, 50, 60 16 10, 20, 30, 40, 50, 60 20 10, 20, 30, 40, 50, 75, 100 25 10, 20, 30, 40, 50, 75, 100 28 Note
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% VS4 VQ7 EVS Conditions VFN Base mounted Series MB Series CS1 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 Base mounted Series MB Series CS1 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 SGP (Steel
D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O.
Digital Flow Switch For Water Series PF2W How to Order ZSE ISE Integrated display type PF2W7 20 03 27 PSE Unit specifications Flow rate range Z I SE3 Thread type Nil M With unit switching function Fixed SI unit Note) 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to 100 l/min 04 20 40 11 Nil N F Rc NPT G PS Note) Fixed unit: Real-time flow rate: l/min Accumulated flow: l Port size Z I SE1
Auto switch model Bore size [mm] 32 40 50 63 80 100 125 D-M9l/M9lV D-M9lW/M9lWV D-M9lA/M9lAV D-A9l/A9lV BMB5-032 BMB5-032 BA7-040 BA7-040 BA7-063 BA7-063 BA7-080 CJ1 D-A3l/A44 D-G39/K39 BMB2-032 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 BS1-125 CJP D-F5l/J59 D-F5lW/J59W D-F59F/F5BA D-F5NT D-A5l/A6l/A59W CJ2 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 BT-08 JCM D-P3DWA BA10-032S BA10-040S BA10-
Range 20 25 32 40 D-C7/C80 D-C73C/C80C D-B5/B64 10 8 9 10 D-B59W 13 13 14 14 D-H7/H7W D-H7BAL 4 4 4.5 5 D-H7C 8.5 5 4 40 7 5 4 35 9 5.5 4.5 40 10 6 5 45 D-G5NBL D-G5NTL D-H7NF CJ1 CJP Since this is a guideline including hysteresis, not meant to be guaranteed.
A : Max. 3.5 AR20-A to AR25-A : Max. 4 AR30-A to AR40-06-A : Max. 8 Model Standard specifications Optional specifications Round type pressure Round type pressure gauge gauge (with color zone) Bracket mount Panel mount P1 P2 A B C D F J H J H J M N Q R S T U V W Y Z AR10-A M5 x 0.8 1/16 25 47.4 11 12.5 M18 x 1 12.5 26 26 25 28 30 4.5 6.5 40 2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22
Auto switch model Bore size [mm] 32 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V BMB5-032 BMB5-032 BA7-040 BA7-040 BA7-063 BA7-063 D-A3/A44 D-G39/K39 BMB2-032 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 D-F5/J59 D-F5W/J59W D-F59F/F5BA D-F5NT D-A5/A6/A59W BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 D-P3DWA BA10-032S BA10-040S BA10-050S BA10-050S BA10-063S BA10-063S D-P4DW BMB3T-040 BMB3T
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.
D [mm] 4 x W 2 x W Body size Coil type B Y 20 AC 85 V Y DC 83 30 AC 85 DC 83 U H 40 AC 95 DC 93 50 AC 98 H DC 96 U Dimensions [mm] Standard specifications Port size A C D E G H J 1(P) 2(A) 3(R) AV2000-m02-1 to 4G(Z)m-A 1/4 1/4 1/4 66 47 24.5 40 33 Width across flats 22 30 AV2000-m02-5 to 6G(Z)m-A AV3000-m03-1 to 4G(Z)m-A 3/8 3/8 3/8 76 50 29.5 40 38 Width across flats 24 35 AV3000-m03-5
Port Cushion valve Bore size (mm) Double clevis type/(D) Z ZZ CDH10 32 40 50, 63 80, 100 160 164 190 238 170.5 175 205 261 Double clevis type U Bore size (mm) Stroke range CDH10 CX +0.3 +0.1 CZ L RR U Z ZZ L Z + Stroke RR CX 32 40 50 63 80 100 to 500 to 500 to 600 to 600 to 750 to 750 23 23 30 30 42 42 10.5 11 15 15 23 23 13 13 17 17 26 26 28 28 40 40 60 60 154 158 182 182 228 228 164.5
(mm) Auto switch model Bore size 50 63 80 100 125 32 40 D-A3/A44 D-G39/K39 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 BMB2-032 BS1-125 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F D-F5BAL D-F5NTL BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 BT-08 D-P5DWL D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV D-Y7BAL BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080 BAP2T-080 BMB4-032 BMB4-050 BMB4-050