SMC Corporation of America
Elite Part Number Search
Search Results "IS10E-40-04-6L-D"

Model: 40 (Standard), Bar Length: 40 (400mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6L (ø6 Elbow), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 5 (5m)

Model: 40 (Standard), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6L (ø6 Elbow), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: F (w/Bracket 2)

Model: 40 (Standard), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 1 (1m), One-touch Fitting: 6L (ø6 Elbow), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: w/o Bracket, DIN Rail Bracket for Controller &
High-voltage Power Supply

Model: 40 (Standard), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 1 (1m), One-touch Fitting: 6L (ø6 Elbow), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
High-voltage Power

D The setting time from when the pressure applied to the pressure switch reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the pressure can be displayed or set by the digital pressure switch.

Note Bracket A ZS-50-A Interchangeable with ISE70 With 2 mounting screws (M4 x 6L) Bracket B ZS-50-B With 2 mounting screws (M4 x 6L) Lead wire with M12 connector: Straight ZS-31-B Lead wire length: 5 m Lead wire with M12 connector: Right-angled ZS-31-C Lead wire length: 5 m 6 ISE70/71 Series For pressure switch precautions and specific product precautions, refer to the Operation Manual on

Model: 40 (Standard, AC Type), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 1 (1m), One-touch Fitting: 6L (ø6 Elbow)

Model: 40 (Standard, AC Type), Bar Length: 34 (340mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6L (ø6 Elbow), Plug Position: R (Opposite Side of High-voltage Cable), Bar Bracket: B (w/Bracket 1)

Model: 42 (Dual AC Type), Bar Length: 40 (400mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 6L (ø6 Elbow), Plug Position: Q (High-voltage Cable Side), Bar Bracket: B (w/Bracket 1)

Style: Pressure Switch w/ T-Spacer, Body Size: 40 (AC40), Thread Type: Rc, Port Size: 04 (1/2), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ L-Shaped Piping Adapter, Body Size: 40 (AC40), Thread Type: Rc, Port Size: 04 (1/2), Set Pressure Range: 6 (0.1 to 0.6 MPa), Pressure Unit of the Scale Plate: MPa, Lead Wire Length: L (3m), Mounting Position: Right

Style: Pressure Switch w/ L-Shaped Piping Adapter, Body Size: AC40, Thread Type: Rc, Port Size: 1/2, Set Pressure Range: 0.1 to 0.6 MPa, Pressure Unit of the Scale Plate: MPa, Lead Wire Length: 3m, Mounting Position: Right

Style: Pressure Switch w/ T-Spacer, Body Size: AC40, Thread Type: Rc, Port Size: 1/2, Set Pressure Range: 0.1 to 0.6 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa

Bracket A Bracket B [F 0] Display units, switch output specifications and diagnostic information selection function ISE70(G): 0.500 MPa/ISE71: 0.800 MPa/ ISE75G: 1.000 MPa/ISE76G: 2.50 MPa/ ISE77G: 5.00 MPa/ISE78G: 8.00 MPa Pressure setting Cross recessed round head screw: Nominal size M4 x 6L Cross recessed round head screw: Nominal size M4 x 6L Item Default setting ISE70(G): 0.050 MPa/ISE71

Style: Pressure Switch with Piping Adapter, Body Size: 40 (AC40), Thread Type: Rc, Port Size: 04 (1/2), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa, Mounting: Right

Style: Pressure Switch with Piping Adapter, Body Size: 40 (AC40), Thread Type: Rc, Port Size: 04 (1/2), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: Z (5m), Pressure Unit of the Scale Plate: MPa, Mounting: Right

Body Size: AC40, Thread Type: Rc, Port Size: 1/2, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa, Mounting: Right

Body Size: AC40, Thread Type: Rc, Port Size: 1/2, Set Pressure Range: 0.1 to 0.6 MPa, Lead Wire Length: 5m, Pressure Unit of the Scale Plate: MPa, Mounting: Right

The base color of the new AC-A series is urban white, maintaining a clean, modern look.The IS10E-A series will end production in March 2025. -- Please select the IS10E-D series for new applications Pressure switch facilitates pressure detection of the line, combined with a piping adapter to allow installation/removal without removing piping ; Available with Rc, NPT or G threads ; Set pressure