SMC Corporation of America
Elite Part Number Search
Search Results "IDK06-100-C1"

Applicable shaft types: S, W, Y d1 = Q1 = M L2 + (3 x P) L1 = L2 = (mm) Size 30 50 63 80 100 Q2 = M Thread M3 x 0.5 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 Rc1/8 Rc 1/4 2.5 4 5 4 5 6.8 (mm) (mm) d1 Size 30 50 63 80 100 100 Q2 M3, M4 M4, M5, M6 M4, M5, M6 M4, M5, M6, M8 M5, M6, M8, M10 Size 30 50 63 80 100 100 6.8 8.5 10.3 8 6.8 8.5 10.3 8 11 2.5 4 to 7 4.5 to 18 6.8 to 11 6.8 to 13

Applicable shaft types: S, W, Y d1 = Q1 = M L2 + (3 x P) L1 = L2 = (mm) Size 30 50 63 80 100 Q2 = M Thread M3 x 0.5 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 Rc1/8 Rc 1/4 2.5 4 5 4 5 6.8 (mm) (mm) d1 Size 30 50 63 80 100 100 Q2 M3, M4 M4, M5, M6 M4, M5, M6 M4, M5, M6, M8 M5, M6, M8, M10 Size 30 50 63 80 100 100 6.8 8.5 10.3 8 6.8 8.5 10.3 8 11 2.5 4 to 7 4.5 to 18 6.8 to 11 6.8 to 13

VC (1) Fluid temperature (C) 10 to 60 (No freezing) 10 to 100 Dusttight, Low jetproof (equivalent to IP65) Enclosure VDW Environment Location without corrosive or explosive gases VQ Valve leakage (cm3/min) 0 (with oil pressure) Mounting orientation Unrestricted VX2 (3) 30/150 or less Vibration/Impact resistance (m/s2) 24, 12 VDC, 100, 110, 200, 220, 230 VAC (50/60 Hz) 100, 200, 220, 230

100 160 Switch Heater Indicator High-temperature type XLA-100/160-X152 Single acting (N.C.) 106 to atmospheric pressure 1010 1011 XLC-100/160-1-X152 Double acting 1 When the standard seal material (FKM) is used XLA/C-100/160(-1)-X152 18-E692 Aluminum High Vacuum Angle Valve Normally Closed, Bellows Seal XLA-100/160-X152 How to Order XLA 100 w e r q X152 A M9N u t y Improved durability of

K V 1 10 XLA S P1P2 XL XL Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2++1/Cn) when in series, and C=C1+C2++Cn, when in parallel.

Axis Movement Speed Position Acceleration Deceleration Pushing Area 2 In-position mode (mm/s) (mm) (mm/s2) (mm/s2) Selection (mm) (mm) (mm) Axis 1 Absolute 100 100.00 1000 1000 1 0 0 5.0 Axis 2 Absolute 100 100.00 1000 1000 1 0 0 5.0 1 Axis 3 Absolute 100 100.00 1000 1000 1 0 0 5.0 Axis 4 Absolute 100 100.00 1000 1000 1 0 0 5.0 Axis 1 Absolute 50 50.00 1000 1000 0 0 0 0.5 Axis 2 Absolute

V None Cannot be selected when t is P or T V V F V None (SI unit only) H V V J V None (SI unit only) P Pressure sensor 0 to 101 Analog output 1 to 5 V T 100 to 100 N Without pressure switch for vacuum/pressure sensor 100 to 100 i Option4 (For details on the Function/Application, refer to page 121.)

Handling Precautions . 98 13.4 Operating environment . 99 13.5 Maintenance and Precautions . 100 13.6 Precautions for actuator with lock . 100 14.

100 120 120 [mm/s] () 5 5 5 5 5 5 [mm/s] () 8 8 8 9 9 9 -110No.JXC-OMT0001CN-C LEHF10 LEHF20 LEHF32 LEHF40 K [mm] 40/15 50/15 70/16 70/16 (2.667) (3.333) (4.375) (4.375) mm/s 80 100 100 100 [mm/s] () 5 5 5 5 [mm/s] () 7 8 8 8 LEHS10 LEHS20 LEHS32 LEHS40 K [mm] 255/76 235/56 235/40 235/40 (3.355) (4.196) (5.875) (5.875) mm/s 70 80 100 120 [mm/s] () 5 5 5 5 [mm/s] () 8 8 9 9 TM -111No.JXC-OMT0001CN-C

500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 2) AWG20 (0.5mm USB JXC-W1-2 -USB DC24V M PWR JXC-W1 2) C PWR DC24V 2) () <> 1.5m () 2) AWG16 (1.25mm JXC-C1 1) 2)PLCDC24V 12.

ZB1-ZSF-A (ZSE10F) 14.5 to 14.5 psi (100 to 100 kPa) 15.2 to 15.2 psi (105 to 105 kPa) Model (Refer to the standard model number for the switch unit on page 9.)

mA or less SAS7: 100 mA or less Internal current consumption (Unit) 100 mA or less SAS9: 65 mA or less SAS5: 65 mA or less SAS7: 8 points SAS9: 4 points SAS3: 8 points SAS5: 4 points Number of inputs 32 points (Based on input block connection) Supply voltage 24 VDC Note 5) SAS3: 240 mA or less Supply current 1.0A or less SAS5: 120 mA or less PNP output (COM.)

Actuating solenoid valve electric signal Valve opening O After a few seconds at 10-6Torr 90% 100% 90% Valve closing Operation time Responce time Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2+...1/Cn) when in series, and C=C1+C2+...Cn, when in parallel. 39 Series XL Technical Data 5 He leakage

Actuating solenoid valve electric signal Valve opening O After a few seconds at 10-6Torr 90% 100% 90% Valve closing Operation time Responce time Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2+...1/Cn) when in series, and C=C1+C2+...Cn, when in parallel. 39 Series XL Technical Data 5 He leakage

100% LVP Hydrochloric acid 38% LVW Hydrofluoric acid 50% LQ1 LQ1 Hydrogen peroxide 60% LQ3 LQ3 Methanol 100% LVN LVN Methyl ethyl Ketone Note 2) Nitric acid 70% LQHB LQHB Note 2) Phosphoric acid 86% TL TIL Caustic potash 85% TLM TILM Sulfuric acid 100% Note 2) TD TID Toluene Note 1,2) TH TIH Xylene Note 2) Sodium hydroxide (caustic soda) 100% Note 2) 1.1.1-Trichloroethane

Link, No Activity (100 Mbps) Communication status of EtherNet/IPTM ports 1 and 2 100 Mbps: Green 10 Mbps: Orange Green LED flashes. Link, Activity (100 Mbps) LINK/ACT1 Orange LED is ON. Link, No Activity (10 Mbps) Orange LED flashes. Link, Activity (10 Mbps) LINK/ACT2. Red LED is ON. IP address has been duplicated.