No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Compressor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER, 737

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Cover R for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Cover L for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Insulation for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER

. ** 32 42.5 17.5 28 17,000 AFW10-N100FM-WS 10,000 CF CF CF 12 flg. ** CF CF CF CF 28,050 AFW16500-N120FM-WS 16,500 * Bottom drain, with mechanical float drain ** ANSI 150# type Threaded water separators are standard with auto drain valves, flanged units with manual drain valves. Manual unit can be substituted on threaded unit, or valves can be omitted on either type.

High speed static neutralization cartridge IZS31-NT (Material: Tungsten) IZS31-NC (Material: Silicon) IZS31-NS (Material: Stainless steel) Power supply cable IZS31-CP (3 m) IZS31-CPZ (10 m) Connection cable A/B for connecting autobalance sensor to the body For driving: IZS31-CF (12P) Low maintenance cartridge IZS31-NJ (Material: Tungsten) IZS31-NK (Material: Silicon) For I/O signals

And then connection cables A (IZS31-CF) and B (IZS31-CR) to the ionizer and Auto balance sensor. When the sensor is connected, the setting of the balance adjustment trimmer on the body is nullified. (4) Frequency selection switch setting Select the ion generating frequency.

Cv = Area x Stroke x A x Cf Time x 29 Area = x Radius 2 or see table B below. Stroke = Cylinder Travel (in.) A = Pressure Drop Constant (see table A) Cf = Compression Factor (see table A) Table B Cylinder Area (Sq. In.)

Cv = Area x Stroke x A x Cf Time x 29 Area = x Radius 2 or see table B below. Stroke = Cylinder Travel (in.) A = Pressure Drop Constant (see table A) Cf = Compression Factor (see table A) Table B Cylinder Area (Sq. In.)

IZF10 C AC adapter AC adapter (AC cord attached) G1 AC adapter (Without AC cord) G2 IZS41 C AC adapter G1 G2 AC adapter (AC cord attached) AC adapter (Without AC cord) IZS41 CF Made to Order Transition wiring cable How to Order 05 08 Full length 8m Full length 5m Full length 2m 02 CF-X13 IZS41 Transition wiring cable length Symbol Cable full length 01 Full length 2m 02 Full length

Made to Order How to Order Transition wiring cable length IZS41 CF X13 For IZS40 Cable full length 1 m 3 m Symbol 01 03 Model with Made-to-order transition wiring cable Available in 1 m increments from 1 m to 20 m. Note 1) 11 m or longer power cables are not CE Marking-compliant. Note 2) Use standard power supply cables for 2 m, 5 m and 8 m lengths.

quality as supply air Hitachi Electronics Engineering Corporation TS-6200 Min. measurable particle dia. 0.1m Intake rate 28.3l/min (0.99CFM) Sampling time: 5min Interval time: 55min Operation frequency: 30cpm Average piston speed: 100mm/s (3.9inls) Mounting: Horizontal no-load Supply pressure: 0.5MPa (72psi) Evaluation of cleanliness inside chamber 100 Particle concentration (particles/cf

.: 0.1 m Intake rate: 28.3 l/min Sampling time: 5 min Interval time: 55 min Operating frequency: 30 cpm Average piston speed: 100 mm/s Mounting: Horizontal no-load Supply pressure: 0.5 MPa Evaluation of air purity inside chamber 100 Particle concentration (particles/cf) RHC 10 MK(2) Laser dust monitor 1 RS Q G Laser dust monitor setting conditions 0.1 RS H A 0.01 0.01 0.1 RZQ 1 10 Cylinder

P(pslq) 1 0 20 30 40 50 60 70 80 90 100 cf 1.68 2.36 3.04 3.72 4.4 5.08 5.76 6.44 7.12 7.80 On lh olher hand it would be wrong to use Boyle's Law in pneumatics. In the case of tools as well as cylinders the change is never lsothermic but always Adiabatic change.

. -12No.EX-OMW1003-A SI Unit Model Indication and How to Order EX600-S CF 1 -X60 SI Unit Output type Symbol Content Protocol 1 PNP (negative common) Symbol Content CF CC-Link IE Field Summary of Product parts No.

P(pslq) 1 0 20 30 40 50 60 70 80 90 100 cf 1.68 2.36 3.04 3.72 4.4 5.08 5.76 6.44 7.12 7.80 On lh olher hand it would be wrong to use Boyle's Law in pneumatics. In the case of tools as well as cylinders the change is never lsothermic but always Adiabatic change.

Measuring conditions 10-CQSXB20-50D Chamber volume Purity of air supplied to chamber 15l Same quality as supply air Evaluation of air purity inside chamber 100 Particle concentration (particles/cf) Hitachi Electronics Engineering Corporation TS-6200 Min. measurable particle dia.: 0.1m Intake rate: 28.3l/min 10 Laser dust monitor 1 Sampling time: 5min Interval time: 55min Operation frequency

0.70 2.00 1.25 3/8-24UNF 2.63 0.19 0.50 1.55 2.19 0.22 0.34 0.25 0.20 2.19 0.56 NPT1/8 0.75 2.53 1.19 1/2-20UNF 3.13 0.20 0.63 1.90 2.69 0.22 0.34 0.25 0.20 2.73 0.56 0.70 NPT1/8 0.75 2.84 1.44 1/2-20UNF 3.75 0.39 0.63 2.30 3.25 0.28 0.41 0.33 0.26 3.23 0.69 0.70 NPT1/4 11 Series NCQ8 Dimensions/NC(D)Q8(Z) Rear clevis / NC(D)Q8C(Z) 056 (9/16") Bushing I.D. 3/16" (Inch) Symbol Bore CJ CG CF

.: 0.1 m Intake rate: 28.3 l/min Sampling time: 5 min Interval time: 55 min Operating frequency: 30 cpm Average piston speed: 100 mm/s Mounting: Horizontal no-load Supply pressure: 0.5 MPa Evaluation of air purity inside chamber 196 100 196 Particle concentration (particles/cf) Pressure converter Regulator (IR2000) RHC 98 98 ITV (Electro-pneumatic regulator) 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6