If 12VDC specifications are required, enter "12" at the end of the assembly part number. 1 2 1 2 P N D side SZ3000-40-6A-D For flat cable 20 pins SZ3000-40-5A-D 1 2 P N 1 2 D side SZ3000-40-8A-D For flat cable 10 pins SZ3000-40-7A-D A connector block assembly can be shipped as an assembly only in the case of double wiring.
Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
Install an additional valve or an SUP/EXH assembly on the DIN rail. 3 Connecting hook 2. Press the manifold in the arrow direction and mount it on the rail. 1. Hook on the rail. A manifold equipped with a valve or a block assembly can be mounted on the DIN rail.
Note 4) F, P, T and S kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. The number of max. stations differs from kit to kit. (Refer to the table below.)
Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.
Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.
(An assembly is shipped under the condition shown in the figure.)
(An assembly is shipped under the condition shown in the figure.)
, making it possible to hold a cylinder intermediate stopping position for an extended time.
mA 40 mA or less Load current 4 V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .
Install an air filter. Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5 m or finer. 8. Interference in oval type release button The following models cannot be used if a box wrench or socket wrench is used. 2. Install an aftercooler, air dryer or water separator, etc.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100 R 1/2 AS121F-U10/
Refer to pages 2-5-40 to 2-5-43 for control unit.
/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt xing brackets 2 pcs. (including 6 M8 bolts) Note 10) Weight (dry state) kg Approx. 180 Approx. 215 Approx. 280 Note 1) When the ambient temperature or circulating uid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 186-1).
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
(Except C kit) F, P, T and S kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. The number of max. stations differs from kit to kit. (Refer to the table below.)
Do not If using the product in an interlocking circuit Provide a double interlocking system, for example a mechanical system. Check the product for proper operation. Otherwise malfunction can result, causing an accident.
40 J (5) Drain guide 1/4 AFM30/40 Float type auto-drain (N.C.) (4) Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right Left AFM20 to 40 N (1) Drain cock with barb fitting: 6 x 4 nylon tubing Float type auto-drain (N.O.) (4) W F (2) AFM30/40 D AFM30/40 Note 1) Drain guide is NPT 1/4 (applicable to AFM30 and 40), and the exhaust port for auto-drain comes
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.