If the chewed portion of the tubing is used as is, this can cause trouble such as air leakage or difficulty in removing the tubing. 2. When mounting a One-touch fitting, use a suitable wrench to tighten the hexagonal flats of the fitting. Moreover, position the wrench at the lower part of the hexagonal flats as close to the threads as possible.
E/40M E L 50 mm Handling Precautions * When used as a stopper, select a model with a stroke of 30 mm or less. * LEYGLE (ball bushing bearing) cannot be used as a stopper. * Workpiece collision in series with guide rod cannot be permitted (Fig. a). * The body should not be mounted on the end.
large load and a high speed, as the piston comes to a stop at the stroke end.
Pad Caution Guide for drop prevention Provide an auxiliary device (example: a guide for preventing the workpieces from dropping) as necessary. Mounting Position As a rule, the unit must be installed horizontally.
Pad Caution Guide for drop prevention Provide an auxiliary device (example: a guide for preventing the workpieces from dropping) as necessary. Mounting Position As a rule, the unit must be installed horizontally.
Pad Caution Guide for drop prevention Provide an auxiliary device (example: a guide for preventing the workpieces from dropping) as necessary. Mounting Position As a rule, the unit must be installed horizontally.
Pad Caution Guide for drop prevention Provide an auxiliary device (example: a guide for preventing the workpieces from dropping) as necessary. Mounting Position As a rule, the unit must be installed horizontally.
" Individual -X '&& &' & (& & )* $ Series MXQ External Dimensions of Adjuster Rubber Stopper (AS/AT) Extension End Body mounting section Body mounting section Table mounting section A Stroke adjustment range (mm) Model Applicable size P B C F G M D E P 1) H J K Q 1) A D 5 16.5 MXQ-AS 6 (L) MXQ 6 (L) 6 7 19 2.5 8 7 M2.5 x 6 12.5 M2.5 x 8 6 8.3 M5 x 0.8 M 15 26.5 MXQ-AS 6 (L)-X11 5 19.5 MXQ-AS
switch brackets are used as a set.
When used as a stopper, select the LEYG series Sliding bearing for a stroke of 30 mm or less. 4. When used as a stopper, fix the main body with a guide attachment (Top mounting or Bottom mounting). If the end of the actuator is used to fix the main body (end mounting), the excessive load acts on the actuator, which adversely affects the operation and life of the product. 9.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8. Cautions for use in an interlock circuit.
(A, B port) Applicable tubing O.D.: 6,1/4" 24.5 1/8 (A, B port) Other dimensions are the same as the grommet type.
the table below, should be considered as a coefficient determined in accordance with each stroke.
This product operates as a device. It does not send any requests.
Continuous Duty When Using a 4 Port Valve as a 3 Port Valve Caution Caution M When using a 4 port valve as a 3 port valve The SJ2000/3000 series can be used as normally closed (N.C.) or normally open (N.O.) 3 port valves by plugging one of the cylinder ports 4(A) or 2(B). However, exhaust ports should be left open. It is convenient when a double solenoid 3 port valve is required.
Wiring should be kept as short as possible.
Note 3) When tightening an auto switch mounting screw (M2.5), use a watchmakers screwdriver with a grip diameter of 5 to 6 mm. Also, set the tightening torque to be 0.05 to 0.15 Nm. As a guide, turn 90 from the position where it comes to feel tight.
The U-shaped groove is machined into the cushion ring in such a way that this acceleration process can proceed smoothly (as a sine function).
back flow mechanism as a standard feature.
How to Order Type 46 (5 port/Base mounted) 10 SS5YJ3 46 05 M5 Type 46 Type S46 ( ) Single solenoid pilot valve is on same side as the A, B port. Clean series CE-compliant M5 x 0.8 R1, R2 port Stations Nil 02 2 stations Valve mounting direction P port thread type Q CE-compliant : : Single solenoid pilot valve is on opposite side as the A, B port.