An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3. Consider the release of residual pressure. Actuators may move suddenly due to residual pressure, which can be dangerous during maintenance procedures. 4.
AK ASS ASR Straight type Easily installed in pipe lines.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
AS1001FG-04-X214 ASV AK Needle Valve/Flow Characteristics VCHC Note) The flow characteristics are representative values.
1 Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting Series AS1F-D Elbow Type/Universal Type Flow adjustable by flat head screwdriver Prevention of an unnecessary manual operation Model Applicable tubing O.D.
Cutout window View A-A' Mounting Standard Stroke GK BP A AA AB AG AH AI AJ AK AL AM AN AO AP B BZ GC GD Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 11 13 75 32 28 54 134 150 108 140 M 8 135 110 4 9 9 104 86.5 15 16 88 37 29 62 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 15 16 88 37 30 62
Use an extension fitting included with the product for the combinations in the table below.
Cutout window View A-A' Mounting Standard Stroke GK BP AG AB A AA AN B GD AH AI AJ AK AL AM AO AP BZ GC Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 13 11 54 75 32 28 134 150 108 140 M 8 135 110 4 9 9 104 86.5 16 15 62 88 37 29 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 16 15 62 88 37 30
2 t AQ ASV AK VCHC ASR ASQ i q o !0 !1 i q o !0 !
3 i Meter-in type Meter-in type AS3211F-02 AS3311F-02 AS ASP ASN AQ ASV AK ASS ASR Component Parts Component Parts No. Description Material Note No.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)]
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: -
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A (w/Caster Adjuster-foot)
Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A (w/Caster Adjuster-foot)