-A-20, CHILLER, 729, 110 lb
-A-20, CHILLER, 30.00000 lb
Noise Filter for HRL200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 1.1 lb
DI Sensor for HRL100/200/300-A*-20/40, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Thermistor Sensor for HRL300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 12 lb
Thermistor Sensor HRL100/200/300-A-20/40, HRS090 AND LARGER CAPACITIES, O88, 10 lb
Accessories Set (Option N), HRL-***-A-20, HRS090 AND LARGER CAPACITIES, O88, 6 lb
Pump Assy for HRS090-A-20 CHILLER. Handle for HRS-PF005. 120 lb. 729.
Flow Rate Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.
Revised Content Edition B Series IR1000 and IR3000 added to Series IR2000. Air operated type IR2120 added to Series IR2000. Order made specifications added. Pages increased from 6 to 16.
Step 20 Step 5 P4 Set pressure P3
Install an air dryer (IDF series), air filter (AF/AFF series), and/ or mist separator (AFM/AM series) to obtain clean compressed air (A compressed air quality of Class 2.4.3, 2.5.3, 2.6.3, or higher according to ISO 8573-1:2010 (JIS B 8392-1:2012) is recommended for operation.). 7. This product and AC adapter do not incorporate protection against lightening surges. 8.
Table.1 Thread Appropriate tightening torque (Nm) 1/2 20 to 25 -7 - AXTS040*-3(B)-X2 External pilot type OUT Port 2(B) OUT Port 2(B) port AXTS040*-3(B)-X2 Pilot air Control valve Pilot air Control valve X Port IN Fig.4 Piping for External Fig.5 Piping for External pilot fluid passage 1 pilot fluid passage 2 Caution The description of the sub plate and piping port do not match.
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: J (w/Automatic Fluid Fill Function)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: M (Applicable to Deionized Water Piping)
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: Applicable to Deionized Water Piping
Signal name Input/output status Description 1 Sig-in+ Input 4-20 mA analog input signal (+) 2 Sig-inInput 4-20 mA analog input signal (-) 3 JOG+ Input JOG operation signal (Move to the extended end direction) 4 JOGInput JOG operation signal (Move to the retracted end direction) 5 PWR_DC24V DC+24 V Power supply 6 PWR_GND Power supply GND 7 Pos-out+ Output 4-20 mA analog output signal (+) 8