Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: JM (J + M)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / With automatic water supply
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: With automatic water supply
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With automatic water supply
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping
Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J
Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: Earth Leakage Breaker
Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M
Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: J + M
Pump capacity 9.4.4 HRSH090-A-20/40-HRSH090-W-20/400.6 60 Circulating fluid pressure [MPa] 0.5 50 Pump head [m] 0.4 40 Outlet Usable flow rate range 0.3 30 Usable flow rate range 0.2 20 Return port 0.1 10 0 0 0 10 20 30 40 50 60 70 Circulating fluid flow [L/min] Fig. 9-8 Pump capacity (HRSH090-A-20/40-HRSH090-W-20/40-) 0 Pump capacity HRSH Series 9-12 HRX-OM-R026 Chapter 9 Documents 9.5
Model number: HRR050-AN/WN-20/40The transition connector from Rc to NPT is enclosed as an accessory. For NPT piping, be sure to use this connector. Model number: HRR050-AF/WF-20/40The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
. 9-1 9.1.2 HRS090-A-40. 9-2 9.1.3 HRS090-A-46. 9-3 9.1.4 HRS090-W-20. 9-4 9.1.5 HRS090-W-40. 9-5 9.1.6 HRS090-W-46. 9-6 9.1.7 Refrigerant with GWP reference . 9-7 9.1.8 Communication specification . 9-7 9.2 Outline dimensions . 9-8 9.2.1 HRS090-A-20/40/46-. 9-8 9.2.2 HRS090-W-20/40/46-. 9-9 9.3 Flow diagram . 9-10 9.3.1 HRS090-A-20/40/46-. 9-10 9.3.2 HRS090-W-20/40/46 . 9-10 9.4 Cooling
Mounting same side MG D-C7 D-C8 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-H7C 50+45(n2) 50 15 10 MGP 15+45( n2 ) (n=2, 4, 6) 2 60+45(n2) 60 15 10 MGQ 15+50( n2 ) (n=2, 4, 6) MGG 2 65 15 10 65+50(n2) 20+50( n2 ) (n=2, 4, 6) 2 MGC 65 20 D-H7LF 10 15+50( n2 ) (n=2, 4, 6) 2 D-B5/B6 D-G5NTL MGF 10 75 15 75+55(n2) 20+50( n2 ) (n=2, 4, 6) 2 15 MGZ D-B59W 75 20 D-A3A D-G39A D-K39A D-A44A CY 10 100