Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.
to AW60-B Filter Regulator with Backflow Function Series AW20K-B to AW60K-B AC AF+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW AW20-B, AW20K-B AW40-B, AW40K-B q Body size 20 30 40 60 Symbol Description g Exhaust mechanism Nil Relieving type N Non-relieving type + Semi-standard h Flow direction Nil Flow direction: Left to right y R Flow direction: Right to left + i Pressure
20 30 40 Symbol Nil B* H* Symbol 02 03 04 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.
20 30 40 Symbol Nil B* H* Symbol 02 03 04 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.
Clean series 10 AF 03 A 30 F J B 21 AF 03 A 30 F J B Copper, fluorine and silicone-free + Low particle generation q w e r t Air filter Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
Large Flow Air Filter AF800/900 Series AC-A Standard Specifications AF-A AF900 AF800 Model AF-A 1 4 1 2 Port size 1 2 1 AR-A Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa AL-A 5 to 60C (No freezing) Ambient and fluid temperature Standard specifications: 5 m Option: 2, 10, 20, 40, 70, 100 m Polycarbonate Filtration Bowl material AW-A Bowl capacity (cm3) 45 cm3 AC-B Weight (kg)
Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR012/018-A/W-10/20-Y HRR-TK001 Nut (M8) HRR024/030-A/W-20-Y Bolt (M8) Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.
l b --" ,m'i$;:f, 4ra 20 Standard Stroke lmm) 30 40 50 60 75 100 125 175 200 225 250 275 300 350 400 150 Y f r N t * w -l Yw Y Ns a a a a a a a a a a a a a o a a a a a a a a a a a a a a a a a '*?
slations) "up to 18 so enoids possible -'up to 24 eoenoids possible A, B port size (inch) A, B port size (metric) spaEleyonamanr'od Manifold D-sub Connector .
Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR010-A/W-10/20-Y HRR012/018-A/W-10/20-Y HRR-TK001 Nut (M8) HRR024/030-A/W-20-Y Bolt (M8) HRR050-A/W-20-Y Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.
B Slotted locking type O.D.
Body size ARJ210-M5BG Accessory Port size Symbol Description JIS Symbol Nil B G With bracket With pressure gauge 1 8 (Male thread) M5 x 0.8 (Female thread) M5 IN OUT M5 x 0.8 (Female thread) Model 1 Relieving type (Standard) (Initial setting) Inlet pressure: 0.7 MPa Outlet pressure: 0.2 MPa Flow rate: 20 /min (ANR) Pressure Characteristics Flow Characteristics Inlet pressure: 0.7 MPa Outlet
O ver range of i nput si gnal Pl ease execut e "i ni t i al i ze ( ref er t o P16) " w hen I TV do not operat e norm al l y af t er rest art i ng t he pow er suppl y. Readi ng or w ri t i ng errors occurred i n EEPRO M . Pl ease cont act us, w hen I TV do not operat e norm al l y af t er i ni t i al i ze.
port regulator) ARB310-00-B ARB210-00-B Can be made into manifold with series VV72.
Pi n assi gn of bus adapt or si de connect or I t em Pi n assi gn I t em Socket assi gn SLD SLD 4 4 3 D B D B CCLi nk I N CCLi nk O U T 3 2 5 D G D G D A 1 2 D A N . C.
Example) ARP30K-03BE-1RY Symbol 20 30 40 Body size Description Nil K Without backflow function With backflow function With backflow function + Nil N F Rc NPT G Thread type + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) a Without mounting option With bracket With set nut (For panel mount) Mounting H + Note 1) Nil E G E1 Note 3) Without pressure gauge Square embedded type pressure
Example) ARP30K-03BE-1RY Symbol 20 30 40 Body size Description Nil K Without backflow function With backflow function With backflow function + Nil N F Rc NPT G Thread type + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) a Without mounting option With bracket With set nut (For panel mount) Mounting H + Note 1) Nil E G E1 Note 3) Without pressure gauge Square embedded type pressure
pressure switch *5 67 Regulator AR20-B to AR60-B Series Regulator with Backow Function AR20K-B to AR60K-B Series AC AF+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW AR40-B, AR40K-B AR20-B, AR20K-B Nq Body size 20 25 30 40 50 60 Symbol Description c Set pressure *6 Nil 0.05 to 0.85 MPa setting 1 0.02 to 0.2 MPa setting + d Exhaust mechanism Nil Relieving type N Non-relieving
Large Flow Air Filter AF800/900 Series AC-A AF-A Standard Specifications AF900 AF800 Model AF-A 1 4 1 2 Port size 1 2 1 AR-A 1.5 MPa Proof pressure Maximum operating pressure 1.0 MPa AL-A 5 to 60C (No freezing) Ambient and fluid temperature Standard specifications: 5 m Option: 2, 10, 20, 40, 70, 100 m Polycarbonate Filtration Bowl material AW-A 45 cm3 Bowl capacity (cm3) AC-B Weight (kg)
ACG20 to 40 AF + ARG + [S] + AL (7) Pressure switch S AF + [S] + ARG ACG20B to 40B ACG20C to 40C AF + AFM + [S] + ARG ACG20 to 40 AF + ARG + AL + [V] Residual pressure relief 3 port valve AW + AL + [V] ACG20A to 40A Port size AF + ARG + [V] V ACG20B to 40B Body size Port size ACG20C to 40C AF + AFM + ARG + [V] Symbol 20 30 40 AW + AFM + [V] ACG20D to 40D 01 02 03 04 1/8 Note 6) When more