SMC Corporation of America
Elite Part Number Search
Search Results "HRS024-A-20-BT"

Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: Rc, Optional specifications: High-temperature environment specification

Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: Rc, Optional specifications: High temperature environmental specification / High pump head specification

Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping

Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping / High pump head specification

Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: Rc, Optional specifications: High pump head specification

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BM (B + M)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BMT (B + M + T)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: G (High Temp Environment Specs)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: GM (G + M)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: GT (G + T)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: J (Automatic Water Supply Function)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: JMT (J + M + T)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: MT (M + T)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: T (High-lift Pump)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: GJ (G + J)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BMTW (B + M + T + W)

Example 1:How many sctm will flow through a valve with a C, of 1 .0 given a supply pressure ot 80 psig and a 20 psi pressure drop? From the chart Fig. 3.10 find 80 psig on the criticalflow line. Next, lind 60 psig (80 psig minus a 20 psi pre*sure drop) on the horizontral axis at the bottom.

Example 1:How many sctm will flow through a valve with a C, of 1 .0 given a supply pressure ot 80 psig and a 20 psi pressure drop? From the chart Fig. 3.10 find 80 psig on the criticalflow line. Next, lind 60 psig (80 psig minus a 20 psi pre*sure drop) on the horizontral axis at the bottom.