Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + W
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS012-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
For the HRS012 to 060 and the HRSE series, alarm code “AL29” (fan motor maintenance) will be activated every 20,000 hours of operation (Note 1). Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
The default setting for alarm code “AL09” is continued operation for the HRS012 to 060.
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 150 (15.7 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 300 (28 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B (w/Earth Leakage Breaker)
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker