Applicable bore size (mm) + 0.048 0 + 0.048 0 10 CJ-T010SUS 3.3 4.5 29 18 3.1 2 9 40 22 32 12 A D L MM N R W Flat type Round type 16 CJ-T016SUS 5 5.5 35 20 6.4 2.5 14 48 28 38 16 Individual -X 10 8 6 8 10 CJ-CF010 13 M4 x 0.7 10 CJ-CR010 16 7 10 12 CJ-CF016 15 M5 x 0.8 12 10 CJ-CR016 Technical data 839 Stainless Steel Cylinder Series CJ5-S/CG5-S Proper Auto Switch Mounting Position (Detection
B TA TL TU TC TX TE TO TT TR TS TH TF TDH10 MB-S03 32 40 50 63 80 100 125 32 40 50 63 80 100 125 +0.070 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 +0.084 0 +0.084 0 46 52 65 75 95 114 136 45 60 60 70 70 90 105 8.5 10 10 15 15 15 18.5 62 80 92 110 130 158 186 50 63 75 90 110 132 160 74 97 109 130 150 184 212 12 17 17 20 20 26 26 13 17 17 22 22 24 24 10 12 12 14 14 17 25 35 45 45 60 60 75 85 89
Applicable bore size (mm) TH TC TDH10 TK TN TT TU TV TW TX TY Material: POM Part no. Applicable bore size (mm) Flat type +0.048 0 +0.048 0 CJ-T010SUS 10 3.3 A D L MM N R W 4.5 29 18 3.1 2 9 40 22 32 12 Round type CJ-T016SUS 16 5 5.5 35 20 6.4 2.5 14 48 28 38 16 CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 CJ-CF016 CJ-CR016 16 10 12 15 M5 x 0.8 7 12 10 6
Min. bending radius (mm) 4 10 15 20 27 35 10 15 23 27 35 45 Fixed end 20 to +60C (Water: 0 to 40C) (No freezing) Operating temperature Material Polyurethane 372 Polyurethane Tubing Series TU/TIUB How to Order 20 TU0425 BU Length per roll Tubing model Symbol Length 20 20 m roll 100 m roll 100 K Color Symbol Color Symbol Color Gray Light gray Neon pink Solid purple Clear purple Solid red Clear
B C D H SNKJ-016B SNLJ-016B SN-020B SN-032B NTJ-010A NTJ-015A NT-02 NT-03 19.6 M12 x 1 4 8.1 M4 x 0.7 3.2 6, 10 17 6, 10 7 21.9 M14 x 1 5 9.2 M5 x 0.8 4 16 19 16 8 30 M20 x 1.5 8 15 M8 x 1.25 5 20 26 20 13 37 M26 x 1.5 8 19.6 M10 x 1.25 6 25 32 25 17 T-bracket 4-TC TH 7 +0.2 0 TU -0.1 -0.3 TN TK TX TV 12 TD H10 TT TY TW Part no.
Air suction filter 13-10-1 Series ZFA Using an ejector with a 2-stage nozzle, the ejector system can be used most efficiently. Air suction filter 13-10-4 Prevents problems related to vacuum circuits or airborne contaminants.
0 10 20 30 40 Circulating fluid temperature (C) HRG010-A HRG010-W 12 12 60 [Hz] 60 [Hz] 10 Cooling capacity (kW) Cooling capacity (kW) 10 50 [Hz] 50 [Hz] 8 8 6 6 4 4 2 2 0 0 0 10 20 30 40 40 0 10 20 30 Circulating fluid temperature (C) Circulating fluid temperature (C) HRG015-A HRG015-W 18 16 60 [Hz] 16 60 [Hz] 50 [Hz] 14 Cooling capacity (kW) Cooling capacity (kW) 14 50 [Hz] 12 12 10 10
60% Ethylene Glycol Physical property value Temperature Density Specific heat C [kg/m 3] [g/l] ([kcal/kg C]) [J/(kgK)] 1.10 x 10 3 3.02 x 10 3 (0.72) 10C 1.08 x 10 3 3.15 x 10 3 (0.75) 20C 1.06 x 10 3 3.27 x 10 3 (0.78) 50C 1.04 x 10 3 3.40 x 10 3 (0.81) 80C Water Density : 1 x 10 3 [kg/m 3] [g/l] Specific heat C: 4.2 x 10 3 [J/(kgK)] (1.0 [kcal/kg C]) 79 Thermo-chiller Series HRZ Fluorinated
Tighten the retaining screws to an appropriate tightening torque within the range given below. 6: 2.1 to 2.5 Nm, 10: 5.9 to 6.4 Nm, 16: 10.8 to 11.8 Nm 3.
IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option.
Select the proper size of cable according to an actual condition.
Laser output power 3 [kW], conversion efficiency 30% The oscillators power consumption is, 3 [kW] 0.3 = 10 [kW] The cooling capacity required for the oscillator is, 10 [kW] 3 [kW] = 7 [kW] Considering a safety factor of 20%, 7 [kW] x 1.2 = 8.4 [kW] W Efficiency Q = P = In this example, using an efficiency of 0.7: 5.1 0.7 = = 7.3 [kW] Q: Heat generation amount Cooling capacity = Considering
5) D-B59W 10 20 75 20 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 75 + 55 (n 2) (n = 2, 3, 4, 5) Note 3) When n is an odd number, an even number that is one larger than this odd number is used for the calculation.
] Circulating fluid Circulating fluid Compressor Compressor Circulating fluid Circulating fluid Compressor Compressor User's equipment HRS Existing model HRS Existing model 30 40 0 10 20 Elapsed time [Minute] This is just an example diagram.
40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)
Select the proper size of cable according to an actual condition.
Material Description Part number No. 4 5 10 NBR Gasket VVQ5000-80A-1 Type 10 NBR Gasket VVQ5000-80A-2 Option A 1 station Note) Spare parts consist of sets containing 10 pcs. each.
[mm] *1 D1 Weight [g] With a rib X (X) Y Nylon Urethane Applicable tubing M L1 Oval type Round type 4 1/8 KQ2L04-01GS1 10 8.2 7.7 10 10 14.8 16.2 17.2 13.3 4.6 3.3 3 4.8 1/4 KQ2L04-02GS1 14 8.2 7.7 10 10 14.8 21.7 21.1 13.3 4.6 3.3 3 14.3 Rib 4, 6 8 to 16 6 1/8 KQ2L06-01GS1 10 10.4 9.7 12 10 15.5 17.3 19.4 13.3 11.4 9 4.5 5.2 1/4 KQ2L06-02GS1 14 10.4 9.7 12 10 15.5 22.8 23.3 13.3 11.4