SMC Corporation of America
Elite Part Number Search
Search Results "EQY32DHA-30B-B6"

D-B5/B6/A3A/A44A/G39A/K39A cannot be mounted on the bore size 20 and 25 cylinder with an air cushion. Note) Adjust the auto switch after confirming the operating condition in the actual setting.

A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current Maximum Output current B7 NC

OUT1<B6> DC2(-) 10k (3) Pulse train signal input circuit The pulse signal input can be selected from the open collector input type and differential input type.

Stainless steel mounting screw kit: BBA3 for D-B5, D-B6, D-G5, and D-K5 Stainless steel mounting screw kit: BBA4 for D-C7, D-C8, and D-H7 When the type D-H7BAL switch is shipped already mounted on a cylinder, the above stainless steel screws are used.

BBA3: D-B5/B6/G5/K5 types Note 3) Refer to page 1047 for details on the BBA3. When the D-G5BA type auto switch is shipped independently, the BBA3 is attached. Set part no.

Pressure Control Equipment Industrial Filters ACG20B/30B/40B Options/Attachments Part No. Options/Attachments part no. ACG20B ACG30B ACG40B Model Description Pressure gauge Note 1) GB2-10AS GB3-10AS GB4-10AS GB2-10AS GB2-3AS AD27 Y200 Y200T IS10M-20 VHS20-01, 02 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.

Pressure Control Equipment Industrial Filters ACG20B/30B/40B Options/Attachments Part No. Options/Attachments part no. ACG20B ACG30B ACG40B Model Description Pressure gauge Note 1) GB2-10AS GB2-3AS AD27 Y200 Y200T IS10M-20 VHS20-01, 02 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.

Unit AC10B to 60B Dimensions A AC10B, 20B Pressure gauge port size F P E K Q N B C G G OUT IN T T K H Pressure gauge (accessory) J L Square embedded type pressure gauge (accessory) Port size M Min. clearance for maintenance Regulator Air filter Drain D AC25B, 30B, 40B, 50B, 55B, 60B A Pressure gauge port size F P E K Q N G G B C IN OUT K Pressure gauge (accessory) J L Square embedded type

Unit AC10B to 60B Dimensions A AC10B, 20B Pressure gauge port size F P E K N Q B C G G OUT IN T T K H Pressure gauge (Option) J L Square embedded type pressure gauge (Option) Port size M Min. clearance for maintenance Regulator Air filter Drain D AC25B, 30B, 40B, 50B, 55B, 60B A Pressure gauge port size F P E K N Q G G B C IN OUT K Pressure gauge (Option) J L Square embedded type pressure

Square embedded type pressure gauge (Option) AV Port size M Min. clearance for maintenance Regulator Air filter Drain D AU AC25B/30B/40B/50B/55B/60B AF A Pressure gauge port size F P E K N Q AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR G G B C IN OUT VEX

Square embedded type pressure gauge (Option) AV Port size M Min. clearance for maintenance Regulator Air filter Drain D AU AC25B/30B/40B/50B/55B/60B AF A Pressure gauge port size F P E K N Q AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR G G B C IN OUT VEX

operation Roller lever VZM450-01-01 VZM450-01-01S VM-08C VM-06CS VM-06C VM-05C VM-02CS VM-02C VM-01CS VM-01C Hard steel roller One way roller lever VZM450-01-02 VZM450-01-02S Polyacetal roller Hard steel roller Straight plunger VZM450-01-05 Polyacetal roller Hard steel roller Roller plunger VZM450-01-06 VZM450-01-06S Toggle lever VZM450-01-08 VZM450-01-30R VM-30CR Red VM-30CB Black VZM450-01-30B

Size, Body, Valve Type: 30B (Size: 3; Body Mat'l: Aluminum; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 3A (24VDC; DIN Terminal w/Surge Voltage Suppressor w/o DIN Connector)

Series LVM CAT.ES70-30B Meeting the most advanced needs of process control Compact Direct Operated 2/3 Port Compact Direct Operated 2/3 Port Valve chamber volume Unit: l LVM09/090 LVM10 (For LVM11) LVM10/100 LVM15/150 LVM20/200 Series 18 11 20 50 84 Valve chamber volume Change in volume depending on open/closed status of valve (pumping volume) 0.01 l or less (Rocker type) Pumping volume

Size, Body, Valve Type: 30B (Size: 3; Body Mat'l: Aluminum; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: P (110VAC; Conduit Terminal w/Surge Voltage Suppressor)

Size, Body, Valve Type: 30B (Size: 3; Body Mat'l: Aluminum; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: P (110VAC; Conduit Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)

Size, Body, Valve Type: 30B (Size: 3; Body Mat'l: Aluminum; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: S (24VDC; Conduit w/Surge Voltage Suppressor)

Size, Body, Valve Type: 30B (Size: 3; Body Mat'l: Aluminum; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: B (100VAC; Grommet w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)

Size, Body, Valve Type: 30B (Size: 3; Body Mat'l: Aluminum; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: A (24VDC; Grommet), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)

Size, Body, Valve Type: 30B (Size: 3; Body Mat'l: Aluminum; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: G (24VDC; DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)