Conforming to OSHA Standard Pressure Relief 3 Port Valve with Locking Holes (Single Action) SeriesVHS20/30/40/50 RoHS How to Order 04 A BS VHS 40 Single action Pressure relief 3 port valve Made to Order X1 Description Body: Red Note) Symbol Body size Symbol Note) Refer to Photo of X1 in Feature 2 for the appearance.
A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Metal) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Rubber) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 3-position Closed center (FHG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Exhaust center (FJG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Pressure center (FIG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 6 Series VS R8 Rubber Seal S HOW TO ORDER VALVE VS R 8 6 FG S 3EZ V1 A03T X1
Output unit How to Order EX510-FC 10 10.16 0.40 Cable length (L) 01 02 05 10 20 60 1 m 2 m 5 m 10 m 20 m 60 m Brown: +24 V Black: Communications + White: Communications Blue: 0 V L Note) (Reference: AWG18) Note) Branch cable length is a maximum of 20 m. Use the cable by cutting it into lengths of 20 m or shorter. w Branch connector (Unit 1 pc.)
Voltage symbol 24 VDC V100-61-3-05 DC 24 VZ 12 VDC V100-61-3-06 DC 12 VZ 100 VAC V100-61-2-01 100/110 VZ 200 VAC V100-61-2-02 200/220 VZ 110 VAC V100-61-2-01 100/110 VZ 220 VAC V100-61-2-02 200/220 VZ 240 VAC V100-61-2-07 240 VZ If an AC specification without DIN Terminal (DO) is selected, always use a DIN connector with surge voltage suppressor as the connector.
Address setting switch (x1): Sets the 1 digit of the PROFIBUS DP node address. Settings 2 switch (8): Sets the 3rd digit of the PROFIBUS DP node address.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
Coil: T (with Power Saving Circuit), Voltage: 5 (24VDC), Cable Length: WO (M8 Connector w/o Connector), Light and Surge Voltage Suppressor: U (w/Light/Surge Voltage Suppressor, Non-polar), 4A, 2B Port Size, Thread Piping: 01 (1/8), Thread Type: F (G)
Coil: T (with Power Saving Circuit), Voltage: 5 (24VDC), Cable Length: WO (M8 Connector w/o Connector), Light and Surge Voltage Suppressor: U (w/Light/Surge Voltage Suppressor, Non-polar), 4A, 2B Port Size, Thread Piping: 01 (1/8), Thread Type: N (NPT)
Coil: with Power Saving Circuit, Voltage: 24VDC, Cable Length: M8 Connector w/o Connector, Light and Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Non-polar, 4A, 2B Port Size, Thread Piping: 1/8, Thread Type: G, Made to Order: -
Coil: with Power Saving Circuit, Voltage: 24VDC, Cable Length: M8 Connector w/o Connector, Light and Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Non-polar, 4A, 2B Port Size, Thread Piping: 1/8, Thread Type: NPT, Made to Order: -
GW unit setup The [Properties] screen will be displayed by double-clicking the [Interface] of the [Configuration table] window [Slot X1]. Tick the box for [Prioritized startup] in the [General] tab and press the [OK] button. The [Properties] screen will be displayed by double-clicking the Slot1 P1 or P2 (communication port using the FSU function) in the [HW Config] screen.
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-34No.EX-OMO0030-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
An example of when the SI unit station number is set to 01 is shown below.
An example of when the SI unit station number is set to 01 is shown below.
Checklist Device type/equipment identification EX245-FPS1 Version: HW/SW 01/1.1.1 Date 2015-July-1st Test engineer 1 John Smith Test engineer 2 Jane Brown System XXX has been checked for engine hood production Remark No. Requirement (mandatory) Yes Remark X No.
ZS-27-01 Front protective cover -11No.PF-OMN0005-E Summary of Product parts Front Item Description Displays the flow value, setting mode, and error indication. Four display modes can be selected: display always in red or green, or display changing from green to red, or red to green, according to the output status (OUT1).
Conditions: Operating pressure 0.5MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1m AS420-02, 03, 04 AS500-06 AS2000-01, 02 AS600-10 AS3000-02, 03 AS4000-02, 03, 04 Circuit 4.12-12
Body size Port size Thread type Nil N F Symbol Port size Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 A spacer or spacer with bracket is required if the valve is combined with modular FRL. SUP SUP Applicable air preparation equipment Spacer with bracket part no. Pressure relief 3 port valve VHS20 VHS30 VHS40 VHS40-06 VHS50 IN OUT Spacer part no.
Coil: T (with Power Saving Circuit), Voltage: 5 (24VDC), Cable Length: W1 (w/M8 Connector Cable, 300mm), Light and Surge Voltage Suppressor: U (w/Light/Surge Voltage Suppressor, Non-polar), 4A, 2B Port Size, Thread Piping: 01 (1/8), Thread Type: F (G), Made to Order: X1 [3-port Specification, 2(B) Port Plug]