SMC Corporation of America
Elite Part Number Search
Search Results "CY3RG25-400-Z73"

Provides high linearity and high precision. 1 Series CYP How to Order CYP 15 Z73 200 Clean rodless cylinder Cylinder bore size Number of auto switches 15 32 15mm 32mm 2 pcs. 1 pc. n pcs. Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.

Piping: G (Centralized Piping), Bore Size: 25mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 1200mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED

Piping: G (Centralized Piping), Bore Size: 25mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 350mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED

Piping: G (Centralized Piping), Bore Size: 25mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 600mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED

Piping: G (Centralized Piping), Bore Size: 25mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 150mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED

Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Guideless] Direct mounted, Table Size Width W(mm): 44, Table Size Height H(mm): 44, Table Surface Treatment: [Anodize] Hard Anodize, Environment: General Purpose, Maximum Load(kg): 1.2, Piping Format: Centralized piping type, Port Screw Type: Rc, Cushion: Rubber cushion, Switch Rail: Yes, Specification: Magnet built-in, Auto Switches: Z73

Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Guideless] Direct mounted, Table Size Width W(mm): 44, Table Size Height H(mm): 44, Table Surface Treatment: [Anodize] Hard Anodize, Environment: General Purpose, Maximum Load(kg): 1.2, Piping Format: Centralized piping type, Port Screw Type: Rc, Cushion: Rubber cushion, Switch Rail: Yes, Specification: Magnet built-in, Auto Switches: Z73

Piping: Centralized Piping, Bore Size: 25mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 1200mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: -, Number: -

Piping: Centralized Piping, Bore Size: 25mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 350mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: -, Number: -

Piston speed Caution The cylinder speed upper limit that retains the particle generation grade is 400 mm/s. Back matter 5 Clean series: Common Precautions 3 Be sure to read before handling. Refer to the main text for detailed precautions for every series.

100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V or less IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are

Piping: G (Centralized Piping), Bore Size: 25mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 400mm

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Auto Switches: Z73, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Lock Position: With head-end lock, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type

Piston speed Caution The cylinder speed upper limit that retains the particle generation grade is 400 mm/s. Back matter 5 Clean series: Common Precautions 3 Be sure to read before handling. Refer to the main text for detailed precautions for every series.