SMC Corporation of America
Elite Part Number Search
Search Results "CY1L10H-300-F7BAL"

Bore Size: 10mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Large Holding Force, Stroke: 100mm, Adjuster: Adjuster Bolt, Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

32, 40 RSDQ 20, 25, 32, 40, 50 MDU 25, 32, 40, 50, 63 CE1 12, 20, 32, 40, 50, 63 MK, MK2 20, 25, 32, 40, 50, 63 CXT 32, 40 Caution Specifications PLC: Programmable Logic Controller D-F7BAL (With indicator light) Precautions D-F7BAL Auto switch model number Consult SMC if using coolant liquid other than water based solution. 2 wire Wiring Output 24V DC Relay/PLC Application Power voltage

BBA2: For D-A7/A8/F7/J7 types Water resistant auto switches, D-F7BAL/F7BAVL are set on the cylinder with the stainless steel screws above when shipped. When an auto switch is shipped independently, BBA2 is attached.

Hs MLU MLGP A B ML1C Proper Auto Switch Mounting Position (mm) Auto Switch Mounting Height (mm) D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7BAL D-F79F D-F7NTL Hs D-A72/A7H D-A80H/A73C D-A80C/F7 D-F7V/F79F D-J79/J79C D-F7W/F7WV D-J79W/F7BAL D-F7BAVL Auto switch type Auto switch type D-F7V D-F7WV D-F7BAVL D-A73 D-A80 D-A7 D-A80 D-A73C D-A80C D-A79W D-F7NTL D-J79C D-A79W Bore size Bore size A Hs

Hs A B A B D-A7H D-A80H D-F7 D-J79 D-F7W D-A79W D-F7WV D-F7V D-F7BAVL D-J79W D-F7F D-F7NTL D-F7BAL Approx. Hs Approx.

BBA2: For D-A7/A8/F7/J7 The above stainless steel screw kit is used for water resistant auto switch types D-F7BAL and F7BAVL when they are shipped mounted on a cylinder. When only a switch is shipped independently, BBA2 screws are attached.

Hs A B D-A7H D-A80H D-F7 D-J79 D-F7W D-A79W D-F7WV D-F7V D-F7BAVL D-J79W D-F79F D-F7NTL D-F7BAL Approx. Hs Approx.

BBA2: For D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped. When a switch is shipped independently, BBA2 screws are attached. 10-8-4 5 Stopper Cylinder: Fixed Mounting Height Series RSQ Weight Mounting Bolt for RSQB (kg) Mounting method: Mounting bolt for throughhole mounting style of RSQB is available as an option.

The above stainless steel screw kit is used for water resistant auto switch type D-F7BAL when it is shipped mounted on a cylinder. Also, BBA2 is included when an auto switch alone is shipped. Example Note) Consult SMC regarding intermediate strokes for sizes 40 through 100 with rubber bumpers.

The above stainless steel screw kit is used for water resistant auto switch type D-F7BAL when it is shipped mounted on a cylinder. Also, BBA2 is included when an auto switch alone is shipped. Example Note) Consult P/A regarding intermediate strokes for sizes 40 through 100 with rubber bumpers.

Note D-F7, J79 D-F7V D-J79C D-F7W, J79W D-F7WV D-F7BAL D-F7F D-F7NTL Kits consist of piston seal, rod seal, and gasket.

U A B D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U Approx. U Approx. U SMC SMC Approx. U A B B A Approx. U D-A73C D-A80C D-J79C B A A B Approx.

Bore Size: 10mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm

Bore Size: 10mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Note 50 63 32 40 Bore size (mm) Action Double acting Reed switch D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W Solid state switch D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F78AVL D-F79F Fluid Air 0.1 to 0.6 MPa Operating pressure Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut. 5 to 60C Ambient and fluid temperature 32, 40 50, 63 BQ-2 Lubrication Not required 3 to

Note 50 63 32 40 Bore size (mm) Action Double acting Reed switch D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W Solid state switch D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F78AVL D-F79F Fluid Air 0.1 to 0.6 MPa Operating pressure Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut. 5 to 60C Ambient and fluid temperature 32, 40 50, 63 BQ-2 Lubrication Not required 3 to

Bore Size: 10mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: Adjuster Bolt, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 10mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: Adjuster Bolt, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Notes Applicable switch F9NW F9NWV Yes Relay, PLC 3-wire (NPN) 24V F79W F7PW Diagnosis indicator (2 color) 5V, 12V IC circuit 3-wire (PNP) MHC2 Reed switch D-A7, A8 D-A73C, A80C D-A7lH, A80H D-A79W Solid state switch D-F7l, J79 D-F7lV D-J79C D-F7lW, J79W D-F7lWV D-F7BAL D-F7lF Model/Specifications Switch mounting screw (M3x0.5 x10l) F9PW F9BW F9BA F9PWV F9BWV Grommet F7BWV J79W

Perpendicular) D-A80C Without indicator light D-A72H Grommet (In-line) D-A73H, A76H D-A80H Without indicator light BQ5-032 32 to 63 D-F7NV, F7PV, F7BV D-F7NWV, F7BWV Diagnosis (2-color indicator) Grommet (Perpendicular) D-F7BAVL Water resistant (2-color indicator) Connector (Perpendicular) D-J79C Solid state auto switch D-F79, F7P, J79 D-F79W, F7PW, J79W Diagnosis (2-color indicator) D-F7BAL