MY1 HT MY1 W MY1 W MY1CW (Cam follower guide type) 16, 20 25, 32, 40, 50, 63 MY2C MY2 H/HT MY3A MY3B MY3M B A B A Proper Auto Switch Mounting Position (mm) D-Z7/Z80 D-Y59/Y7P D-Y7W D-Y7BA D-M9V D-M9WV D-M9AV D-A9 D-Y69/Y7PV D-Y7WV D-M9 D-M9W D-M9A Bore size (mm) A B A B A B A B A B 16 20 25 32 40 50 63 74 86 70 90 94 106 90 110 102 118 102 118 97 123 97 123 132 148 132 148 127 153
Same side 75 90 120 (n 4) 2 120 + 50 (n 2) 2 90 + 50 (n 4) 2 20 + 50 Different sides D-B59W n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 2, 3, 4 90 + 50 (n 2) n = 2, 4, 6 120 + 5 (n 2) 75 + 50 (n 2) Same side n = 2, 4, 6, 8 120 90 1 pc. 15 35 80 90 Different sides 75 100 Same side 35 + 30 (n 2) 75 + 30 (n 2) 80 + 30 (n 2) 90 + 30 (n 2) D-A3 D-G39 D-K39 Different
(V) A B A B Auto Switch Specifications Grommet D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y59B D-Y7P D-Y7PV D-Y69A D-Y59A Perpendicular D-Y69B Auto switch part no.
Main circuit of switch Main circuit of switch Main circuit of switch D-Y59B D-Y69B D-Y59A D-Y69A D-Y7P(V) Auto switch model OUT Black D0.5 9 10 10 Lead wire length (m) 3 50 53 53 205 83 87 87 DC () Blue D-Y7P, D-Y7PV Dimensions DC (+) Brown D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B Mounting screw M2.5 x 4l Slotted set screw Mounting screw M2.5 x 4l Slotted set screw OUT Black Indicator
Main circuit of switch Main circuit of switch Main circuit of switch D-Y59B D-Y69B D-Y59A D-Y69A D-Y7P(V) Auto switch model OUT Black D0.5 9 10 10 Lead wire length (m) 3 50 53 53 205 83 87 87 DC () Blue D-Y7P, D-Y7PV Dimensions DC (+) Brown D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B Mounting screw M2.5 x 4l Slotted set screw Mounting screw M2.5 x 4l Slotted set screw OUT Black Indicator
(same side) 65 60 D-Y59/Y69/Y7P/Y7PV 1 or 2 pcs. (different sides) 20 20 2 pcs. (same side) 65 70 Solid state switch D-Y7W/Y7WV 20 25 1 or 2 pcs. (different sides) 75 70 2 pcs. (same side) D-Y7BAL 20 25 1 or 2 pcs.
SB) 7 5 5 5 3 7.5 5 3 5 3 90 90 5 90 5 A MHZ 20 20 20 20 (3 x SA) 20 20 MHF Section SD SD MHL MHSJ3-63D MHSJ3-80D MHR MHK 4 MHS 10 4 11 MHC 3 5 3 5 90 90 MHT 5 MHY 20 20 20 20 MHW -X (mm) L 2H9 3H9 4H9 6H9 8H9 J 20 21 24 28 32 HB 65 75 88 106 130 HA 76 86 103 125 158 FX 22 26 32 40 50 EO 15.5 19 24 31 41 EC 11.5 15 18 23 31 DO 35.5 40 48 59 73 DC 31.5 36 42 51 63 AE 36 37 46 50 57 CA 9.5
After that, incline the lever by 90 and confirm that the indicator light is not on and does not show either red or green.
Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-Y5, D-Y6, D-Y7P, D-Y7PV (With indicator light) Using flexible cable as standard spec.
D-Y59 D-Y7P 10 5 2 pcs. 15 10 1 pc. D-Y69 D-Y7PV 5 2 pcs. 5 1 pc.
As a guide, turn 90 from the position where it comes to feel tight.
MK(2) Resistance RS Q G Adjustment dial RS H A RZQ Adjustment dial rotation angle MI W S 90 CEP1 Stopper direction can be changed within 90 CE1 CE2 The stopper lever can be rotated 90.
MK(2) Resistance RS Q G Adjustment dial RS H A RZQ Adjustment dial rotation angle MI W S 90 CEP1 Stopper direction can be changed within 90 CE1 CE2 The stopper lever can be rotated 90.
Note 1) The above figures are when the in-line electrical entry type D-A9/M9/M9W/M9AL/Z7/Z80/Y59/Y7P/Y7W/ Y7BAL auto switches are mounted. Note 2) Z7/Z80/Y59/Y7P/Y7W/Y7BAL cannot be mounted on 20 to 32. 444 Double Power Cylinder Series MGZ/MGZR Operating Range Auto Switch Mounting Bracket: Part No.
0.4 0.5 0.3 0.6 Operating time (s/90) Operating time (s/90) MHY2-25D MHW2-40D 20 200 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 15 150 10 100 5 50 0 0 0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0 Operating time (s/90) Operating time (s/90) 12-10-7 7 180 Angular Style Air Gripper Cam Style Series MHY2 Size: 10, 16, 20, 25 How to Order MHY 2 16 2 D F9BW S Number of fingers
0.4 0.5 0.3 0.6 Operating time (s/90) Operating time (s/90) MHY2-25D MHW2-40D 20 200 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 15 150 10 100 5 50 0 0 0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0 Operating time (s/90) Operating time (s/90) 12-10-7 7 180 Angular Style Air Gripper Cam Style Series MHY2 Size: 10, 16, 20, 25 How to Order MHY 2 16 2 D F9BW S Number of fingers
Minimum Stroke for Auto Switch Mounting (mm) Auto switch Applicable auto switch model No. of auto switches mounted D-Z7, D-Z8 D-Y7W, D-Y7WV D-Y59, D-Y69 D-Y7P, D-Y7PV 5 10 5 10 10 15 1 pc. 2 pcs.
90 55 70 45 23 18 0.2 0.3 3/8 0.5 0.7 1/2 0.8 1.0 3/4 1.2 1.4 1 1 1/4 2.2 2.4 5.0 5.2 32 1 1/2 3.6 3.8 6.8 7.0 40 Symbols 5.5 5.7 2 Valve type Operation N.C.
MRQ Auto Switch Internal Circuit DD-90 20OUT () Weight OUT () Brown Contact protection box CD-P11 CD-P12 Reed switch (g) OUT ( ) D-90 D-97 Auto switch model OUT ( ) Blue Black line 5 5 0.5 Lead wire length (m) 23 23 3 D-97 37 37 5 Contact protection box CD-P12 Choke coil OUT (+) Brown Dimensions OUT (+) Reed switch Zener diode Zener diode D-90 OUT () OUT () Blue Black line Resistor LED
As a rule, it can be turned about 90 past the point at which tightening can be felt. Flat head watchmakers screw driver Auto switch 5 to 6 Switch mounting screw (M2.5 x 4l) (included) Auto Switch Specifications (1) Switches (switch rail) can be added to the standard type (without switch rail).