2 wire Wiring type NPN PNP Output type 24VDC Relay, PLC IC circuit, Relay, PLC Applicable loads Power supply voltage 5, 12, 24VDC (4.5 to 28VDC) 10mA or less Current consumption 28VDC or less 24VDC (10 to 28VDC) Load voltage 40mA or less 80mA or less Load current 5 to 40mA 1.5V or less (0.8V or less at 10mA load current) 4V or less 0.8V or less Internal voltage drop Leakage current 100A
In particular, a deterioration of exhaust characteristics due to an unclean pump and invasion of the atmospheric moisture can be the major factor. 15 Series XM, XY Auto Switch Specifications Auto Switches Common Specifications Reed switch Solid state switch Auto switch type Leakage current 3-wire: 100A or less, 2-wire: 0.8mA or less Operating time 1.2ms 1ms or less Impact resistance 300m
Bearing Style: M (Slide Bearing), Bore Size: 20mm, Thread: Rc, Stroke: 100mm
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7,
Bearing Style: Ball Bushing Bearing, Bore Size: 20mm, Port Type: NPT, Stroke: 100mm, A: Air Cushion, Auto Switch: Y59A--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -
Bearing Style: Ball Bushing Bearing, Bore Size: 16mm, Port Type: Rc (Or M5x0.8 for 16 Bore), Stroke: 100mm, A: Air Cushion, Auto Switch: Y59A--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -
Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Auto switches marked with a symbol are produced upon receipt of order. Note) No need to add -X61 at the end of the part number for the flexible lead wire for D-Y type auto switch, because it adopts flexible lead wire as standard.
In-line AC DC 3-wire (NPN) Y69A Y59A IC circuit 5 V 12 V 3-wire (PNP) Y7PV Y7P IC circuit Solid state switch Y69B Y59B 2-wire 12 V Relay, PLC Grommet Yes Standard 24 V 3-wire (NPN) Y7NWV Y7NW IC circuit 5 V 12 V Diagnosis (2-color indication) 3-wire (PNP) Y7PWV Y7PW IC circuit 12 V 2-wire Y7BWV Y7BW Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) IC circuit 5 V, 12 V 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since
Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Auto switches marked with a symbol are produced upon receipt of order. Note) No need to add -X61 at the end of the part number for the flexible lead wire for D-Y type auto switch, because it adopts flexible lead wire as standard.
wire (NPN) 3-wire (PNP) Y59A Y69A IC circuit 5 V 12 V Y7P Y7PV Solid state switch 12 V Y59B Y69B 2-wire Relay, PLC Grommet Yes 24 V 3-wire (NPN) 3-wire (PNP) Y7NW Y7NWV IC circuit 5 V 12 V Diagnosis (2-color indication) Y7PW Y7PWV Y7BW Y7BWV 2-wire 12 V Water resistant (2-color indication) Y7BA Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ
In-line AC DC 3-wire (NPN) Y69A Y59A IC circuit 5 V 12 V 3-wire (PNP) Y7PV Y7P IC circuit Solid state switch Y69B Y59B 2-wire 12 V Relay, PLC Grommet Yes Standard 24 V 3-wire (NPN) Y7NWV Y7NW IC circuit 5 V 12 V Diagnosis (2-color indication) 3-wire (PNP) Y7PWV Y7PW IC circuit 12 V 2-wire Y7BWV Y7BW Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ
Z Y59AZ Refer to pages 8 and 9 for information related to auto switches. 1 Guide Table Series MGF Specifications Action Double acting Fluid Air Proof pressure 1.5MPa Maximum operating pressure 1.0MPa Minimum operating pressure 0.1MPa Ambient and fluid temperature 10 to 60C Piston speed 20 to 200mm/s Cushion Rubber bumper at both ends Lubrication Non-lube + 1.0 0 Stroke length tolerance mm
ZY Y59AZ Specifications Standard Strokes Action Double acting Model Standard stroke (mm) Intermediate stroke Fluid Air A spacer with a width of 5, 10, 15, 20 or 25mm is installed to manufacture intermediate strokes (5mm increments) other than standard strokes.
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 24 V Grommet 5 V, 12 V Diagnostic indication (2-color indication) Water resistant (2-color indication) 12 V 2-wire Y7BA Solid state switches marked with are produced upon receipt of order. 0.5 mNil (Example) Y59A 3 mL (Example) Y59AL 5 mZ (Example) Y59AZ
Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Auto switches marked with a symbol are produced upon receipt of order. Note) No need to add -X61 at the end of the part number for the flexible lead wire for D-Y type auto switch, because it adopts flexible lead wire as standard.
Guide Suffix: Guide 1 Shaft, Bore Size: 25mm, Port Thread: Rc; Bore 25, 32, M5; Bore 15 Only, Stroke: 300mm, Auto Switch: Y59AZ--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 5M
Solid state switch 2-wire 12 V Yes Yes Relay, PLC 5 V, 12 V 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN equivalent) Z76 5 V IC circuit Grommet Z73 Z80 24 V 12 V 5 V, 12 V 100 V 2-wire Relay, PLC 100 V or less IC circuit Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ
Z (Example) Y59AZ 1 Compact Hydraulic Cylinder: 10MPa Series CHKDB Specifications Light and compact aluminum body. Auto switches can be mounted. Auto switch mounting does not affect overall length. A wide range of operating pressures, bore sizes, and standard strokes make more selections possible to suit your individual needs.