SMC Corporation of America
Elite Part Number Search
Search Results "CNA2WB100-125-D"

F 4-9.5 F 4-8 4-6 3-6.5 4-5 G 3-4 Y 3.5 Y 6 E E E Y 8 10 6 34 40 18 C C C A B D A A B D B D Dimensions Dimensions Dimensions (mm) (mm) (mm) A B C D E F Y A B C D E F G Y A B C D E F Y Model Model Model ZP40HB ZP63HB ZP100HB 40 41.4 28.4 43.2 20.5 30 13 63 65.1 45.5 67.6 31.5 50 4.5 21.5 100 103.1 68.6 106.7 47.5 80 35.5 ZP50HB ZP80HB ZP125HB 50 51.9 35.7 54 24 40.5 16.5 80 83 58.4 85.1 37

Standard dimensions marked with * will be as follows to the rod diameter (D). Enter any special dimension you require. D 6 D 1 mm, 6 < D 25 D 2 mm, D > 25 D 4 mm 3. In the case of the double rod type and single acting retraction type, enter the dimensions when the rod is retracted. 4. Only one side of a double rod can be manufactured. 5.

D-M9 D-F9W D-F9BAL 7-6-22 23 Compact Cylinder with Auto Switch: Standard Type Double Acting, Single Rod Series CDQ2 Operating Range 180 200 Bore size (mm) Auto switch model 12 125 140 160 63 80 100 16 50 20 25 32 40 D-A7(H)(C) D-A80(H)(C) D-A9(V) D-Z7 D-Z80 D-F7(V) D-J79(C) D-F7W(V) D-F7BA(V)L D-F7NTL D-F79F D-F9(V) D-F9W(V) D-F9BA(V)L D-Y59 D-Y69 D-Y7P(V) D-Y7W(V) D-Y7BAL D-P5DW 13 13

JIS symbol Auto switch model D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Bore size (mm) Standard strokes (mm) 40 50 63 80 100 125 160 25 to 1000 25 to 1000 25 to 1000 25 to 1300 25 to 1500

D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F MGT Auto switch model Auto switch model D-G59F D-G5 D-K59 D-G5W D-K59W D-G5NTL D-G5BAL D-C7 D-C80 D-H7 D-H7W D-H7HF D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-C7 D-C80 D-C73C D-C80C D-A9 D-M9 D-M9W D-M9 D-M9W D-B5 D-B64 D-B59W D-C73C D-C80C D-A9 Bore size (mm) Bore

D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style .

side D D D D Max. 14.5 (SJ3000-00-P) (SJ2260) (SJ3260) (SJ2260) SOL.b SOL.b SOL.b SOL.b 15 D side U side (12) (12) (12) (12) With manual operation of the pressure adjustment screw (14) SOL.a (14) SOL.a (14) SOL.a (14) SOL.a 22.5 90.5 22.9 56.2 Note) Reduces supply pressure from the D side of manifold.

(Only for units compatible with M12 PROFIBUS DP , CC-Link communication connectors) SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000 D D D D Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.

CB Solid state switch: D-F9B, D-F9N, D-F9P, D-F9BW, D-F9NW, D-F9PW CV/MVG B Stroke B Stroke E Model Operating range A CXW 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXS6 MXS8 MXS12 MXS16 MXS20 MXS25 10 2 9.6 9.6 9.6 21.6 27.6 -0.4 -0.4 -0.4 11.6 17.5 CXS 11.6 2.5 14.9 9.9 10.9 18.9 26.9 51.9 4.9 -0.1 0.9 8.9 16.9 41.9 15.6 3 32.4 22.4 12.4 14.4 24.4 45.4 74.4 22.4 12.4 2.4

(mm) Model Order no. d: Thread nominal size H B C JS10-4-070 JS16-5-080 JS20-8-125 JS32-10-125 JS40-14-150 JS63-18-150 M40.7 3.2 8.1 DA00127 7 M50.8 4 9.2 DA00128 8 d M81.25 5 15 DA00036 13 M101.25 6 19.6 DA06 17 C M141.5 8 25.4 DA00186 22 M181.5 11 31.2 DA00188 27 H B D-X Technical Data 1157 JS Series Dimensions JS10, 16 M M Center of sphere U D J U F B C E G P H A R Use the precision spanner

Auto Switch Mounting Dimensions D-Z7, D-Z8 (Reed switch) D-Y5, D-Y6, D-Y7 (Solid state switch) Dimension A Bore size Switch types 6 10 15 20 25 32 A D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B D-Y7NWV, D-Y7PWV, D-Y7BWV D-Y7NW, D-Y7PW, D-Y7BW D-Y7BAL D-Z7, D-Z8 0.2 0.7 6.0 0.7 6.5 1.2 Auto Switch Mounting Caution When mounting and securing auto switches, they should be inserted into the cylinder's

Auto Switch Mounting Height [mm] Auto switch model D-F5m D-J59 D-F59F D-F5mW D-J59W D-F5BA D-F5NT D-Y59m D-Y7P D-Y7mW D-Y7BA D-Z7m D-Z80 D-M9m D-M9mW D-M9mA D-A9m D-A9mV D-M9mV D-M9mWV D-M9mAV D-A5m D-A6m D-A59W D-Y69m D-Y7PV D-Y7mWV D-P3DWA D-P4DW D-G39 D-K39 D-A3m D-A44 Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23 30.5 23 32.5 25 35 24.5

(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Hs Hs Ht Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S

(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Ht Hs Hs Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S

, same side) 120 125 130 15 25 100 105 (n 2) 2 25 + 55 (n 2) 2 100 + 55 (n 4) 2 120 + 55 (n 4) 2 (n 4) 2 125 + 55 (n 4) 2 130 + 55 (n 4) 2 D-F5NTL D-F59F 105 + 55 n = 4, 8, 12, 16 15 + 55 n (Same side) n = 2, 4, 6, 8 n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 1 100 10 25 120 125 130 105 D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 2 (Different sides, same side

switch Auto switch Ht Ht A A 32 B B L 9-6-20 21 Series MNB Cylinder with Lock Double Acting, Single Rod Proper Auto Switch Mounting Position D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5