(Or None in the Case of No Switch), X Option: XB7 [Cold Resistant Cylinder (-40°C)]
Magnet: None, Style: Air Pressure Style, Mounting: Basic Style, Bore Size: 32mm, Piping: NPT, Stroke: 75mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Coldproof Cylinder
Magnet: None, Style: Air Pressure Style, Mounting: Integral Clevis, Bore Size: 32mm, Piping: NPT, Stroke: 75mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Coldproof Cylinder
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch
(Or None in the Case of No Switch), X Option: XB7 [Cold Resistant Cylinder (-40°C)]
(Or None in the Case of No Switch), X Option: XB7 [Cold Resistant Cylinder (-40°C)]
I XB7 -Low Temp. D -With Built in Magnet (Not available as std. on single acting models, XB6 & XB7) I XBg -Low Friction I XCO -Stainless Steel Rod LNumber of Auto-swircnes -2 pcs. S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .
-XA Change of rod end shape Heat resistant cylinder (150C) -XB6 -XB7 Cold resistant cylinder -XB9 Low speed cylinder (10 to 50 mm/s) -XB13 Low speed cylinder (5 to 50 mm/s) Auto Switch Mounting Bracket Part No.
Action/ Type Single rod Double rod Single rod/ Extension Single rod/ Retraction Applicable bore size Symbol Specification 12 to 25 Standard Standard D Built-in magnet CQS-M Rod end male thread CQS-C With rubber bumper CQS-F 12 to 25 With boss on head end LF G CQS Foot, Flange CQSD Double clevis style 10-, 11Clean series 20Copper and Fluorine-free XB6 Heat-resistant cylinder (10 to 150 C) XB7
I XB7 -Low Temp. D -With Built in Magnet (Not available as std. on single acting models, XB6 & XB7) I XBg -Low Friction I XCO -Stainless Steel Rod LNumber of Auto-swircnes -2 pcs. S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .
Symbol -XB7 Cold Resistant Cylinder (40 to 70C) 4 Air cylinder which changed the seal material and grease, so that it could be used even at lower temperature down to 40C. Applicable Series Series Description Model Action Note Page for the standard type Double acting, Single rod Except with auto switch. Mounting bracket: Basic type only.
Symbol Specifications -XA Change of rod end shape -XB6 Heat resistant cylinder (150C) w/o auto switch only -XB7 Cold resistant cylinder w/o auto switch only -XB9 Low speed cylinder (10 to 50 mm/s) -XB10 Intermediate stroke (Using exclusive body) -XB11 Long stroke type, Air-hydro type only -XB13 Low speed cylinder (5 to 50 mm/s) -XB14 Cylinder with heat resistant auto switch 16 to 63 only
Length of lead between switch body and protector should be less than 1 m. 3,4 CD-P switch 18 9 VOLT 15,5 3.4 38 46 6-11-46 46 Option Series C85 1 High Temperature XB6 2 Low Temperature XB7 C85 Mounting Bore size Stroke XB6 C85 Mounting Bore size Stroke XB7 N, E, F, Y 8, 10, 12, 16, 20, 25 mm N, E, F, Y 20, 25 mm Standard cylinder packing are replaced with special ones and other modifications
NCM -XA Change of rod end shape Minimum Stroke for Auto Switch Mounting Heat resistant cylinder (150C) -XB6 Standard Stroke NCA -XB7 Cold resistant cylinder -XB9 Low speed cylinder (10 to 50 mm/s) Maximum manufacturable stroke (mm) No. of auto switches mounted Standard stroke(1) (mm) Long stroke (mm) Bore size (mm) Model 2 D-XB13 Low speed cylinder (5 to 50 mm/s) 1 -XC4 With heavy duty scraper
Symbol Specifications -XA Change of rod end shape -XB6 Heat resistant cylinder (150C) w/o auto switch only -XB7 Cold resistant cylinder w/o auto switch only -XB9 Low speed cylinder (10 to 50 mm/s) -XB10 Intermediate stroke (Using exclusive body) -XB11 Long stroke type, Air-hydro type only -XB13 Low speed cylinder (5 to 50 mm/s) -XB14 Cylinder with heat resistant auto switch 16 to 63 only
XB6 High temperature resistant cylinder XB7 Low lemperature resistant cylinder xBg Low speed cylinder Modification ol rod end %srrc I SERIES NCJ2 Standard Type: Double Acting/Single Rod Series NCJ2 Bore Size s6, a1O, s16 Special options ffi Hrgh tmpetature tvpe mTowlempeEiure itpe Tow speed ope'rat-bn NC iDI J2 .-T se page 16 lor specilicalions of special options.