SMC Corporation of America
Elite Part Number Search
Search Results "CLSF250-350-D"

D D side Applicable makers Valve stations MB1 For Mitsubishi Electric Corporation TA1 For OMRON Corporation FU1 For Fuji Electric Co., Ltd.

CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B

Outside diameter Nozzle size L2 Note1) D L1 H1 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 1.5 2 1.5 2 1.5 2 1.5 2

(Only for units compatible with M12 PROFIBUS DP , CC-Link communication connectors) SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000 D D D D Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.

Auto Switch Proper Mounting Position (Detection at stroke end) and Its Mounting Height Auto Switch Proper Mounting Position [mm] Auto switch model D-A5l D-A6l D-A3l D-A3lC D-A44 D-A44C D-G39 D-G39C D-K39 D-K39C D-B59W D-Z7l D-Z80 D-Y59l D-Y69l D-Y7P D-Y7PV D-Y7lW D-Y7lWV D-Y7BA D-G5l D-K59 D-G5NT D-G5lW D-K59W D-G5BA D-G59F D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV

C c OFF OFF OFF ON OFF D d OFF OFF OFF OFF ON Power off Turn on the power E E OFF OFF OFF OFF OFF again When multiple alarms in alarm groups A to D occur, the relevant OUT 0 to 3 will be ON.

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: Rc, Stroke: 100mm, Option: w/o Cushion, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit Built-in

Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: Rc, Stroke: 500mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Part No. 25 350, 400, 450, 500 75, 100, 125, 150, (Band and screw are included.) 32 350, 400, 450, 500, 600 Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other

Part No. 25 350, 400, 450, 500 75, 100, 125, 150, (Band and screw are included.) 32 350, 400, 450, 500, 600 Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other