Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
[ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 W 5.5 0 0 2.5 W 7.5 2.0 2.0 0.5 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 A 16.5 15.0 22.0
Built-in rubber bumper reduces the metal noise that occurs when piston stops. 1 Air Cylinder Double Acting, Single Rod JMB Series 32, 40, 45, 50, 56, 63, 67, 80, 85, 100 How to Order With auto switch JMDB 32 50 M9BW B With auto switch (Built-in magnet) Not available without magnet Number of auto switches Nil 2 S 1 3 3 n n Mounting B Basic Auto switch Bore size Nil Without auto switch 32
MGPS50 50 11 12 A 13 B 14 1 2 3 4 5 50 80 7 8 9 A 10 B 15 16 6 17 NBR 18 NBR 19 A NBR 20 B NBR / (mm) 50 MGP50-PS 19 18 17 80 MG80-PS 20 17 20 GR-S-010(10g 18 18. 18-1.
B 0.2 A 0.2 Bore size A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 8.
Replacement Actuator (Cylinder) CY1F R B 10 Stroke Note) -XB10 or -XB11 is not required at the end of the part number for intermediate or long strokes.
B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.
CJ2-Z Series 10, 16 Air Cylinder 10-/1121-/22RoHS How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Rubber bumper (Standard) Air cushion Nil A 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location 2 pcs. 1 pc. n pcs.
When auto switches D-M9/M9W/Y59 D-M9A D-Y7, Y7W are used A B L Auto Switch Hysteresis MHZ When auto switches D-M9V/M9WV/Y69 D-M9AV D-Y7V, Y7WV are used Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc. MHF A B MHL L MHR MHK MHS Max.
Magnet: With Magnet, Mounting: Front Rectangular Flange Type, Bore Size: 80mm, Port Thread Type: NPT, Stroke: 200mm, Rod End Nut: With Rod End Nut, Cushion: With Cushion in Both Sides, Port Position: Port on Top - Cushion Valve Down, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 1m, Number: -
Magnet: With Magnet, Mounting: Front Rectangular Flange Type, Bore Size: 50mm, Port Thread Type: Rc, Stroke: 200mm, Rod End Nut: With Rod End Nut, Cushion: With Cushion in Both Sides, Port Position: Port on Top - Cushion Valve Down, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Magnet: D (With Magnet), Mounting: FY (Front Rectangular Flange Type), Bore Size: 80mm, Port Thread Type: TN (NPT), Stroke: 200mm, Rod End Nut: A (With Rod End Nut), Cushion: With Cushion in Both Sides, Port Position: B (Port on Top - Cushion Valve Down), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: M (1m)
Magnet: D (With Magnet), Mounting: FY (Front Rectangular Flange Type), Bore Size: 50mm, Port Thread Type: Rc, Stroke: 200mm, Rod End Nut: A (With Rod End Nut), Cushion: With Cushion in Both Sides, Port Position: B (Port on Top - Cushion Valve Down), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical
Clean Series: Vacuum Suction Type, Magnet: Built-in Magnet, Series: J2, Mounting: Basic Style, Bore Size: 16mm, Stroke: 200mm, Cushion: Air Cushion, Head Cover Port Location: Perpendicular to Axis, Version: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 L 40 150 A F Z M9BW 21 C D M 2 L 40 150 A Z M9BW Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Solid state Auto switch M9B, M9BW Reed
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 L 40 150 A F Z M9BW 21 C D M 2 L 40 150 A Z M9BW Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Solid state Auto switch M9B, M9BW Reed
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Manual override Nil B Non-locking push type Locking slotted type Number of auto switches Nil S N 2 pcs. 1 pc. n pcs.
In the case of mounting auto switch from B direction Step 2) Insert the auto switch into the auto switch installation groove from direction B. A B MHZ MHF Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates.