DC AC 0.5 1 3 5 () (M) (L) (Z) M9NV M9N IC 3 NPN 5V 3 PNP M9PV M9P 12V 2 12V M9BV M9B M9NWV M9NV IC 3 PNP M9PWV M9PW 3 NPN 5V 12V 2 2 12V M9BWV M9BW 24V M9NAV M9NA IC 3 PNP M9PAV M9PA PLC 3 NPN 5V 12V 2 2 12V M9BAV M9BA 2 2 P3DW 3 NPN A96V A96 IC 12V 100V A93V A93 2 24V 5V 100V A90V A90 IC PLC 12V 0.5m D-M9N M 1m D-M9NM L 3m D-M9NL Z 5m D-M9NZ 1 17 - 7-2. -1516
A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV
Weight (g) CRBU2W10 CRBU2W15 CRBU2W20 CRBU2W30 90 CRBU2W40 90 Vane type Model (size) 90 270 180 90 270 180 180 270 180 270 180 90 270 Rotating angle Single vane Double vane 469 47.1 263 140 142 143 72 47.5 258 255 491 480 72 73 47 Body of rotary actuator Auto switch unit + 2 switches 30 50 60 46.5 30 Angle adjuster 30 90 150 203 47 90 100 90 100 90 90 100 90 100 100 Rotating angle 158 308
(102) 90 (102) 108 (122) 108 (122) 12 14 18 25 30 32 40 50 2 2 2 2 2 2 3 3 20 20 20 13 14 14 20 20 M5 x 0.8 depth 7.5 M5 x 0.8 depth 8 M6 x 1 depth 12 Up to 300 301 to 1500 M8 x 1.25 depth 16 M10 x 1.5 depth 16 M10 x 1.5 depth 22 M12 x 1.75 depth 22 No trunnion mounting female thread is provided for clean series. ( ): Denotes the dimensions for long stroke.
1 Smooth Cylinder CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 RE A B Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure REC CX 0.04 Minimum operating pressure MPa CY 12 16 0.03 MQQ M 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377) RZQ MI W S CEP1 Stable operation possible even at a low speed of 5 mm/s (Measurement based on JIS B 8377) Sliding
J C A B DFull stroke -X 20Data eEntire stroke extension by pressurizing A, B and C ports. 10-10-1 2 3 Position Cylinder Series RZQ 32, 40, 50, 63 How to Order RZQ 32 200 100 A M9N Mounting style Number of auto switches A B L F G D Nil Both ends tapped 2 pcs.
Symbol :: C17 Symbol :: C20 Symbol :: C21 The rotation angle can be adjusted between 90 to 190. The rotation angle can be adjusted between 90 to 190.
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.
Series MHL2 112210, 16, 20, 25, 32, 40 Parallel Type Wide Opening Air Gripper How to Order 11 Vacuum suction type Clean series 11MHL 2 16 D 1 M9N 22MHL 2 16 D 1 M9N Wide opening Number of auto switches 2 pcs. 1 pc. n pcs.
Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ Since there are other applicable auto switches than listed, refer to page 8-7-22 for details.
55 75 80 90 75 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 80 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 90 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 20 + 35 (n 2) (n = 2, 3, 4, ) (Different surfaces) D-A44C n 75 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 80 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 90 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 55 + 50 (n 2) (n = 2, 3, 4, ) (Same surface) 1 10 75 80 90 2 (Different
95 100 60 65 70 75 80 85 90 95 100 105 M5 x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l M5 x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l 65 70 75 80 85 90 95 100 105 140 165 75 80 85 90 95 100 105 110 115 150 175 M5 x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 140l x 165l M5 x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 110l x 115l x 150l x 175l
(Resin, Carbon steel) Roller 590 RS2H Series The roller lever direction can be changed in 90 steps. To adapt the roller lever of the stopper to the work piece direction, the roller lever can be positioned in 4 different directions in 90 steps around the piston rod.
-X 2 10 1 MRHQ 0 0 0.2 0.4 0.6 0.8 0.2 0.4 0.5 0.3 0.6 MA Operating time (s/90) Operating time (s/90) MHY2-25D MHW2-40D D20 200 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 15 150 10 100 5 50 0 0 0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0 Operating time (s/90) Operating time (s/90) 703 180 Angular Type Air Gripper Cam Type MHY2 Series 10, 16, 20, 25 How to Order MHY 2 16
(CCW: Counterclockwise, C: Center, CW: Clockwise) C C C C CW CCW CW CCW CW CCW CW CCW Left 90: Right 90 Left 45: Right 45 Left 90: Right 30 Left 60: Right 90 Working Principle This model uses a 3-position 5-port solenoid valve (pressure center).
Rack & Pinion Type Rotary Actuator Series 11-CRA1-Z Size: 30, 50 RoHS How to Order 11 Vacuum suction type Clean series Nil Auto switch No D Built-in magnet B Mounting Basic L Foot Shaft type S Single shaft W Double shaft 30 Size 50 11 C D R A 1 B S 50 90 Z M9B Rotating angle Number of auto switches 90 180 100 90 180 100 190 Nil S 2 pcs. 1 pc. 190 Type of auto switch (For model with auto switch
Operating Pressure 0.15 MPa 0.04 J Kinetic Energy Note2) 0.03 J Speed Adjustable Range Note1) 0.07 to 0.5 sec/90 Fluid and Ambient Temperature 5 to 60 oC Shaft Type Both shafts (Long shaft side: w/ Key, Short shaft side: single spanner flat) Note 1) Since sticking and/ or malfunction may occur with slower speed than 0.5 sec/90, use the product within the speed adjusting range.
100 120 90 100 110 130 95 105 115 135 CKQ 8 8 Arm Proper Tightening Torque 9 Bore size (mm) Proper tightening torque (Nm) 12 16 20, 25 32, 40 50, 63 0.5 to 0.7 2.8 to 3.5 11.5 to 14.0 24 to 30 75 to 90 8 9.5 Fig. 1 Flange Mounting 11 Caution The mounting bolt for the rod flange or head flange should be tightened to the torque shown in the table below. 10.5 Bore size Thread size Tightening